{"id":"https://openalex.org/W4323022471","doi":"https://doi.org/10.1109/tbcas.2023.3251321","title":"A Prototype Wearable Device for Noninvasive Monitoring of Transcutaneous Oxygen","display_name":"A Prototype Wearable Device for Noninvasive Monitoring of Transcutaneous Oxygen","publication_year":2023,"publication_date":"2023-03-02","ids":{"openalex":"https://openalex.org/W4323022471","doi":"https://doi.org/10.1109/tbcas.2023.3251321","pmid":"https://pubmed.ncbi.nlm.nih.gov/37028012"},"language":"en","primary_location":{"id":"doi:10.1109/tbcas.2023.3251321","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbcas.2023.3251321","pdf_url":null,"source":{"id":"https://openalex.org/S80299757","display_name":"IEEE Transactions on Biomedical Circuits and Systems","issn_l":"1932-4545","issn":["1932-4545","1940-9990"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Circuits and Systems","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5005997016","display_name":"Vladimir Vakhter","orcid":"https://orcid.org/0000-0003-0003-7279"},"institutions":[{"id":"https://openalex.org/I107077323","display_name":"Worcester Polytechnic Institute","ror":"https://ror.org/05ejpqr48","country_code":"US","type":"education","lineage":["https://openalex.org/I107077323"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Vladimir Vakhter","raw_affiliation_strings":["Electrical and Computer Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA"],"raw_orcid":"https://orcid.org/0000-0003-0003-7279","affiliations":[{"raw_affiliation_string":"Electrical and Computer Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA","institution_ids":["https://openalex.org/I107077323"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5010829173","display_name":"Burak Kahraman","orcid":"https://orcid.org/0000-0002-2095-2653"},"institutions":[{"id":"https://openalex.org/I107077323","display_name":"Worcester Polytechnic Institute","ror":"https://ror.org/05ejpqr48","country_code":"US","type":"education","lineage":["https://openalex.org/I107077323"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Burak Kahraman","raw_affiliation_strings":["Electrical and Computer Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA"],"raw_orcid":"https://orcid.org/0000-0002-2095-2653","affiliations":[{"raw_affiliation_string":"Electrical and Computer Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA","institution_ids":["https://openalex.org/I107077323"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5050919105","display_name":"Guixue Bu","orcid":null},"institutions":[{"id":"https://openalex.org/I117023288","display_name":"Analog Devices (United States)","ror":"https://ror.org/01545pm61","country_code":"US","type":"company","lineage":["https://openalex.org/I117023288"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Guixue Bu","raw_affiliation_strings":["Analog Devices, Inc., Wilmington, MA, USA"],"raw_orcid":"https://orcid.org/0000-0002-1096-2962","affiliations":[{"raw_affiliation_string":"Analog Devices, Inc., Wilmington, MA, USA","institution_ids":["https://openalex.org/I117023288"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5056752586","display_name":"Foroohar Foroozan","orcid":"https://orcid.org/0000-0002-6502-3727"},"institutions":[{"id":"https://openalex.org/I117023288","display_name":"Analog Devices (United States)","ror":"https://ror.org/01545pm61","country_code":"US","type":"company","lineage":["https://openalex.org/I117023288"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Foroohar Foroozan","raw_affiliation_strings":["Analog Devices, Inc., Wilmington, MA, USA"],"raw_orcid":"https://orcid.org/0000-0002-6502-3727","affiliations":[{"raw_affiliation_string":"Analog Devices, Inc., Wilmington, MA, USA","institution_ids":["https://openalex.org/I117023288"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5031435587","display_name":"\u00dclk\u00fchan G\u00fcler","orcid":"https://orcid.org/0000-0002-4723-4424"},"institutions":[{"id":"https://openalex.org/I107077323","display_name":"Worcester Polytechnic Institute","ror":"https://ror.org/05ejpqr48","country_code":"US","type":"education","lineage":["https://openalex.org/I107077323"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Ulkuhan Guler","raw_affiliation_strings":["Electrical and Computer Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA"],"raw_orcid":"https://orcid.org/0000-0002-4723-4424","affiliations":[{"raw_affiliation_string":"Electrical and Computer Engineering Department, Worcester Polytechnic Institute, Worcester, MA, USA","institution_ids":["https://openalex.org/I107077323"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.6653,"has_fulltext":false,"cited_by_count":26,"citation_normalized_percentile":{"value":0.90010322,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":98,"max":99},"biblio":{"volume":"17","issue":"2","first_page":"323","last_page":"335"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10977","display_name":"Optical Imaging and Spectroscopy Techniques","score":0.9952999949455261,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11579","display_name":"Cardiovascular and Diving-Related Complications","score":0.9930999875068665,"subfield":{"id":"https://openalex.org/subfields/2740","display_name":"Pulmonary and Respiratory Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/oxygen","display_name":"Oxygen","score":0.7380706667900085},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.6162524819374084},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.5787006616592407},{"id":"https://openalex.org/keywords/partial-pressure","display_name":"Partial pressure","score":0.5140465497970581},{"id":"https://openalex.org/keywords/liquid-oxygen","display_name":"Liquid oxygen","score":0.502704381942749},{"id":"https://openalex.org/keywords/firmware","display_name":"Firmware","score":0.49163132905960083},{"id":"https://openalex.org/keywords/limiting-oxygen-concentration","display_name":"Limiting oxygen concentration","score":0.4912375807762146},{"id":"https://openalex.org/keywords/oxygen-sensor","display_name":"Oxygen sensor","score":0.48765480518341064},{"id":"https://openalex.org/keywords/wearable-computer","display_name":"Wearable computer","score":0.4340451955795288},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.31936222314834595},{"id":"https://openalex.org/keywords/chemistry","display_name":"Chemistry","score":0.1903592348098755},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.14191675186157227},{"id":"https://openalex.org/keywords/computer-hardware","display_name":"Computer hardware","score":0.11871203780174255},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.11285924911499023}],"concepts":[{"id":"https://openalex.org/C540031477","wikidata":"https://www.wikidata.org/wiki/Q629","display_name":"Oxygen","level":2,"score":0.7380706667900085},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.6162524819374084},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.5787006616592407},{"id":"https://openalex.org/C68463220","wikidata":"https://www.wikidata.org/wiki/Q27165","display_name":"Partial pressure","level":3,"score":0.5140465497970581},{"id":"https://openalex.org/C205965903","wikidata":"https://www.wikidata.org/wiki/Q618153","display_name":"Liquid oxygen","level":3,"score":0.502704381942749},{"id":"https://openalex.org/C67212190","wikidata":"https://www.wikidata.org/wiki/Q104851","display_name":"Firmware","level":2,"score":0.49163132905960083},{"id":"https://openalex.org/C89169090","wikidata":"https://www.wikidata.org/wiki/Q593204","display_name":"Limiting oxygen concentration","level":3,"score":0.4912375807762146},{"id":"https://openalex.org/C17734536","wikidata":"https://www.wikidata.org/wiki/Q286588","display_name":"Oxygen sensor","level":3,"score":0.48765480518341064},{"id":"https://openalex.org/C150594956","wikidata":"https://www.wikidata.org/wiki/Q1334829","display_name":"Wearable computer","level":2,"score":0.4340451955795288},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.31936222314834595},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.1903592348098755},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.14191675186157227},{"id":"https://openalex.org/C9390403","wikidata":"https://www.wikidata.org/wiki/Q3966","display_name":"Computer hardware","level":1,"score":0.11871203780174255},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.11285924911499023},{"id":"https://openalex.org/C178790620","wikidata":"https://www.wikidata.org/wiki/Q11351","display_name":"Organic chemistry","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D000076251","descriptor_name":"Wearable Electronic Devices","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000076251","descriptor_name":"Wearable Electronic Devices","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000076251","descriptor_name":"Wearable Electronic Devices","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D001785","descriptor_name":"Blood Gas Monitoring, Transcutaneous","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D001785","descriptor_name":"Blood Gas Monitoring, Transcutaneous","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D001785","descriptor_name":"Blood Gas Monitoring, Transcutaneous","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010100","descriptor_name":"Oxygen","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D010100","descriptor_name":"Oxygen","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D010100","descriptor_name":"Oxygen","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D012867","descriptor_name":"Skin","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012867","descriptor_name":"Skin","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012867","descriptor_name":"Skin","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/tbcas.2023.3251321","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbcas.2023.3251321","pdf_url":null,"source":{"id":"https://openalex.org/S80299757","display_name":"IEEE Transactions on Biomedical Circuits and Systems","issn_l":"1932-4545","issn":["1932-4545","1940-9990"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Circuits and Systems","raw_type":"journal-article"},{"id":"pmid:37028012","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/37028012","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on biomedical circuits and systems","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G2535215340","display_name":null,"funder_award_id":"OAC-2203827","funder_id":"https://openalex.org/F4320335353","funder_display_name":"National Science Foundation of Sri Lanka"}],"funders":[{"id":"https://openalex.org/F4320309065","display_name":"Analog Devices","ror":"https://ror.org/01545pm61"},{"id":"https://openalex.org/F4320335353","display_name":"National Science Foundation of Sri Lanka","ror":"https://ror.org/010xaa060"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":32,"referenced_works":["https://openalex.org/W1978447879","https://openalex.org/W1991732192","https://openalex.org/W2030661231","https://openalex.org/W2081937135","https://openalex.org/W2085446806","https://openalex.org/W2146413126","https://openalex.org/W2169458189","https://openalex.org/W2475767983","https://openalex.org/W2614284214","https://openalex.org/W2708382985","https://openalex.org/W2900112719","https://openalex.org/W2977718165","https://openalex.org/W2987631307","https://openalex.org/W2992095197","https://openalex.org/W3009063690","https://openalex.org/W3018257432","https://openalex.org/W3026126000","https://openalex.org/W3090661188","https://openalex.org/W3097468189","https://openalex.org/W3097564282","https://openalex.org/W3109228218","https://openalex.org/W3135694162","https://openalex.org/W3151068974","https://openalex.org/W3181013774","https://openalex.org/W4200087685","https://openalex.org/W4200372773","https://openalex.org/W4205652186","https://openalex.org/W4281772028","https://openalex.org/W4283832164","https://openalex.org/W4308089882","https://openalex.org/W4309270032","https://openalex.org/W4312788469"],"related_works":["https://openalex.org/W2086276246","https://openalex.org/W3116986465","https://openalex.org/W1971657708","https://openalex.org/W2094915194","https://openalex.org/W2012890259","https://openalex.org/W915682155","https://openalex.org/W2030573174","https://openalex.org/W2008558600","https://openalex.org/W2392713276","https://openalex.org/W2009720026"],"abstract_inverted_index":{"Transcutaneous":[0],"oxygen":[1,13,25,30,93,121,147,169,205],"monitoring":[2],"is":[3,32,55,80,88,101,218],"a":[4,107,123,126,132,184,191],"noninvasive":[5],"method":[6,79],"for":[7,37,90,115],"measuring":[8,146],"the":[9,16,27,35,65,77,82,96,116,143,150,155,165,204,208,222,225,235],"partial":[10,170],"pressure":[11,171,206],"of":[12,34,84,119,125,145,187],"diffusing":[14,148],"through":[15],"skin,":[17],"which":[18],"strongly":[19],"correlates":[20],"with":[21,111,122],"changes":[22,61,159,166,202],"in":[23,26,50,160,167,190,198,203,207,224,231],"dissolved":[24],"arteries.":[28],"Luminescent":[29],"sensing":[31],"one":[33],"techniques":[36],"assessing":[38],"transcutaneous":[39,92,120,168],"oxygen.":[40],"Intensity-":[41],"and":[42,62,72,177],"lifetime-based":[43,78,236],"measurements":[44,66,94,230],"are":[45],"two":[46],"well-known":[47],"methods":[48],"used":[49],"this":[51],"technique.":[52,237],"The":[53,181,216],"latter":[54],"more":[56],"immune":[57],"to":[58,69,141,173,195,200,220,227],"optical":[59],"path":[60],"reflections,":[63],"making":[64],"less":[67],"vulnerable":[68],"motion":[70],"artifacts":[71],"skin":[73,100,151],"color":[74],"changes.":[75],"Although":[76],"promising,":[81],"acquisition":[83],"high-resolution":[85],"lifetime":[86,117,161,192],"data":[87],"crucial":[89],"accurate":[91],"from":[95,149],"human":[97,139,232],"body":[98,210],"when":[99],"not":[102],"heated.":[103],"We":[104],"have":[105],"built":[106],"compact":[108],"prototype":[109,156,182,217],"along":[110],"its":[112],"custom":[113],"firmware":[114],"estimation":[118],"provision":[124],"wearable":[127],"device.":[128],"Furthermore,":[129],"we":[130],"performed":[131],"small":[133],"experiment":[134],"study":[135],"on":[136],"three":[137],"healthy":[138],"volunteers":[140],"prove":[142],"concept":[144],"without":[152],"heating.":[153],"Lastly,":[154],"successfully":[157,228],"detected":[158],"values":[162],"driven":[163],"by":[164,212],"due":[172],"pressure-induced":[174],"arterial":[175],"occlusion":[176],"hypoxic":[178,213],"gas":[179,214],"delivery.":[180,215],"resolved":[183],"minimum":[185],"change":[186],"1.34":[188],"ns":[189],"that":[193],"corresponds":[194],"0.031":[196],"mmHg":[197],"response":[199],"slow":[201],"volunteer's":[209],"caused":[211],"believed":[219],"be":[221],"first":[223],"literature":[226],"conduct":[229],"subjects":[233],"using":[234]},"counts_by_year":[{"year":2025,"cited_by_count":10},{"year":2024,"cited_by_count":7},{"year":2023,"cited_by_count":9}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
