{"id":"https://openalex.org/W2908486990","doi":"https://doi.org/10.1109/tbcas.2018.2890657","title":"A Novel Expandable Catheter Wireless Amplified NMR Detector for MR Sensitivity Accessing the Kidney in Rodent Model","display_name":"A Novel Expandable Catheter Wireless Amplified NMR Detector for MR Sensitivity Accessing the Kidney in Rodent Model","publication_year":2019,"publication_date":"2019-01-04","ids":{"openalex":"https://openalex.org/W2908486990","doi":"https://doi.org/10.1109/tbcas.2018.2890657","mag":"2908486990","pmid":"https://pubmed.ncbi.nlm.nih.gov/30624224"},"language":"en","primary_location":{"id":"doi:10.1109/tbcas.2018.2890657","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbcas.2018.2890657","pdf_url":null,"source":{"id":"https://openalex.org/S80299757","display_name":"IEEE Transactions on Biomedical Circuits and Systems","issn_l":"1932-4545","issn":["1932-4545","1940-9990"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Circuits and Systems","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5069083681","display_name":"Roshan Timilsina","orcid":"https://orcid.org/0000-0001-7904-5516"},"institutions":[{"id":"https://openalex.org/I177721651","display_name":"Oakland University","ror":"https://ror.org/01ythxj32","country_code":"US","type":"education","lineage":["https://openalex.org/I177721651"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Roshan Timilsina","raw_affiliation_strings":["Department of Physics, Oakland University, Rochester, MI, USA"],"affiliations":[{"raw_affiliation_string":"Department of Physics, Oakland University, Rochester, MI, USA","institution_ids":["https://openalex.org/I177721651"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5074747392","display_name":"Chunqi Qian","orcid":"https://orcid.org/0000-0003-4528-4572"},"institutions":[{"id":"https://openalex.org/I177721651","display_name":"Oakland University","ror":"https://ror.org/01ythxj32","country_code":"US","type":"education","lineage":["https://openalex.org/I177721651"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Chunqi Qian","raw_affiliation_strings":["Department of Physics, Oakland University, Rochester, MI, USA"],"affiliations":[{"raw_affiliation_string":"Department of Physics, Oakland University, Rochester, MI, USA","institution_ids":["https://openalex.org/I177721651"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5069083681"],"corresponding_institution_ids":["https://openalex.org/I177721651"],"apc_list":null,"apc_paid":null,"fwci":0.6773,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.70262348,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":96},"biblio":{"volume":"13","issue":"2","first_page":"444","last_page":"453"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10378","display_name":"Advanced MRI Techniques and Applications","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10378","display_name":"Advanced MRI Techniques and Applications","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11279","display_name":"Lanthanide and Transition Metal Complexes","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11993","display_name":"Atomic and Subatomic Physics Research","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/imaging-phantom","display_name":"Imaging phantom","score":0.7098984122276306},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.6023361682891846},{"id":"https://openalex.org/keywords/detector","display_name":"Detector","score":0.5909783840179443},{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.5203189849853516},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.4483441710472107},{"id":"https://openalex.org/keywords/amplifier","display_name":"Amplifier","score":0.44234007596969604},{"id":"https://openalex.org/keywords/nuclear-magnetic-resonance","display_name":"Nuclear magnetic resonance","score":0.3281328082084656},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.28583037853240967},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.23209354281425476},{"id":"https://openalex.org/keywords/optoelectronics","display_name":"Optoelectronics","score":0.20714294910430908},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.09158819913864136},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.08679777383804321}],"concepts":[{"id":"https://openalex.org/C104293457","wikidata":"https://www.wikidata.org/wiki/Q28324852","display_name":"Imaging phantom","level":2,"score":0.7098984122276306},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.6023361682891846},{"id":"https://openalex.org/C94915269","wikidata":"https://www.wikidata.org/wiki/Q1834857","display_name":"Detector","level":2,"score":0.5909783840179443},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.5203189849853516},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.4483441710472107},{"id":"https://openalex.org/C194257627","wikidata":"https://www.wikidata.org/wiki/Q211554","display_name":"Amplifier","level":3,"score":0.44234007596969604},{"id":"https://openalex.org/C46141821","wikidata":"https://www.wikidata.org/wiki/Q209402","display_name":"Nuclear magnetic resonance","level":1,"score":0.3281328082084656},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.28583037853240967},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.23209354281425476},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.20714294910430908},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.09158819913864136},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.08679777383804321},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.0},{"id":"https://openalex.org/C46362747","wikidata":"https://www.wikidata.org/wiki/Q173431","display_name":"CMOS","level":2,"score":0.0}],"mesh":[{"descriptor_ui":"D000818","descriptor_name":"Animals","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000818","descriptor_name":"Animals","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000818","descriptor_name":"Animals","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000818","descriptor_name":"Animals","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D003198","descriptor_name":"Computer Simulation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D003198","descriptor_name":"Computer Simulation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D003198","descriptor_name":"Computer Simulation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D003198","descriptor_name":"Computer Simulation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004560","descriptor_name":"Electricity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004560","descriptor_name":"Electricity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004560","descriptor_name":"Electricity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004560","descriptor_name":"Electricity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007668","descriptor_name":"Kidney","qualifier_ui":"Q000000981","qualifier_name":"diagnostic imaging","is_major_topic":false},{"descriptor_ui":"D007668","descriptor_name":"Kidney","qualifier_ui":"Q000000981","qualifier_name":"diagnostic imaging","is_major_topic":false},{"descriptor_ui":"D007668","descriptor_name":"Kidney","qualifier_ui":"Q000000981","qualifier_name":"diagnostic imaging","is_major_topic":false},{"descriptor_ui":"D007668","descriptor_name":"Kidney","qualifier_ui":"Q000000981","qualifier_name":"diagnostic imaging","is_major_topic":false},{"descriptor_ui":"D009682","descriptor_name":"Magnetic Resonance Spectroscopy","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D009682","descriptor_name":"Magnetic Resonance Spectroscopy","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D009682","descriptor_name":"Magnetic Resonance Spectroscopy","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D009682","descriptor_name":"Magnetic Resonance Spectroscopy","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D019047","descriptor_name":"Phantoms, Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019047","descriptor_name":"Phantoms, Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019047","descriptor_name":"Phantoms, Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019047","descriptor_name":"Phantoms, Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D023421","descriptor_name":"Models, Animal","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D023421","descriptor_name":"Models, Animal","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D023421","descriptor_name":"Models, Animal","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D023421","descriptor_name":"Models, Animal","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D051381","descriptor_name":"Rats","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D051381","descriptor_name":"Rats","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D051381","descriptor_name":"Rats","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D051381","descriptor_name":"Rats","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D057785","descriptor_name":"Catheters","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D057785","descriptor_name":"Catheters","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D057785","descriptor_name":"Catheters","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D057785","descriptor_name":"Catheters","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D059015","descriptor_name":"Wireless Technology","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D059015","descriptor_name":"Wireless Technology","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D059015","descriptor_name":"Wireless Technology","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D059015","descriptor_name":"Wireless Technology","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true}],"locations_count":3,"locations":[{"id":"doi:10.1109/tbcas.2018.2890657","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbcas.2018.2890657","pdf_url":null,"source":{"id":"https://openalex.org/S80299757","display_name":"IEEE Transactions on Biomedical Circuits and Systems","issn_l":"1932-4545","issn":["1932-4545","1940-9990"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Circuits and Systems","raw_type":"journal-article"},{"id":"pmid:30624224","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/30624224","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on biomedical circuits and systems","raw_type":null},{"id":"pmh:oai:europepmc.org:6057783","is_oa":false,"landing_page_url":"https://www.ncbi.nlm.nih.gov/pmc/articles/6446567","pdf_url":null,"source":{"id":"https://openalex.org/S4306400806","display_name":"Europe PMC (PubMed Central)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1303153112","host_organization_name":"European Bioinformatics Institute","host_organization_lineage":["https://openalex.org/I1303153112"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Text"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/6","display_name":"Clean water and sanitation","score":0.4099999964237213}],"awards":[{"id":"https://openalex.org/G3432720332","display_name":null,"funder_award_id":"R00EB016753","funder_id":"https://openalex.org/F4320332161","funder_display_name":"National Institutes of Health"}],"funders":[{"id":"https://openalex.org/F4320332161","display_name":"National Institutes of Health","ror":"https://ror.org/01cwqze88"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":41,"referenced_works":["https://openalex.org/W195831858","https://openalex.org/W623773607","https://openalex.org/W1040935121","https://openalex.org/W1513140202","https://openalex.org/W1522191951","https://openalex.org/W1964347090","https://openalex.org/W1974528356","https://openalex.org/W1985877698","https://openalex.org/W1990118810","https://openalex.org/W1992824594","https://openalex.org/W2013816305","https://openalex.org/W2016668493","https://openalex.org/W2024183800","https://openalex.org/W2027065149","https://openalex.org/W2029524551","https://openalex.org/W2031677052","https://openalex.org/W2034223990","https://openalex.org/W2040811201","https://openalex.org/W2042001272","https://openalex.org/W2045217354","https://openalex.org/W2056015481","https://openalex.org/W2064253886","https://openalex.org/W2070804938","https://openalex.org/W2086400767","https://openalex.org/W2111388536","https://openalex.org/W2117423897","https://openalex.org/W2145164645","https://openalex.org/W2167233877","https://openalex.org/W2168887049","https://openalex.org/W2184444345","https://openalex.org/W2214687469","https://openalex.org/W2222678387","https://openalex.org/W2225843840","https://openalex.org/W2560321621","https://openalex.org/W2661308997","https://openalex.org/W2883410072","https://openalex.org/W4233764193","https://openalex.org/W4249760698","https://openalex.org/W4285719527","https://openalex.org/W6619755773","https://openalex.org/W6686222551"],"related_works":["https://openalex.org/W2899084033","https://openalex.org/W2417440389","https://openalex.org/W4244157427","https://openalex.org/W2734382758","https://openalex.org/W4385556839","https://openalex.org/W4378746257","https://openalex.org/W2109481748","https://openalex.org/W2381719890","https://openalex.org/W2076005643","https://openalex.org/W2400155998"],"abstract_inverted_index":{"This":[0],"paper":[1],"demonstrates":[2],"the":[3,43,49,74,83,99,115,160,164,173,176,205,212,220,232],"enlarged":[4],"effective":[5,89,233],"range":[6,234],"for":[7,66,235],"MRI":[8,15],"sensitivity":[9,117,237],"enhancement":[10,238],"with":[11,18,96],"a":[12,19,36,62,105,110,121,149,179,187,195,216],"deformable":[13,130,165],"catheter":[14,64,227],"coils":[16],"integrated":[17],"wirelessly":[20],"powered":[21],"amplifier.":[22],"The":[23,56,224],"expandable":[24,226],"balloon":[25,63],"wireless":[26],"amplified":[27],"nuclear":[28],"magnetic":[29],"resonance":[30,92],"detector":[31,198],"(WAND)":[32],"is":[33,58,79,167,209],"constructed":[34],"on":[35,61],"copper-clad":[37],"polyimide":[38],"film":[39],"to":[40,86,113,142,148,154,156],"resonate":[41],"at":[42,53,143,185],"first":[44],"and":[45,97,108],"second":[46],"harmonics":[47],"of":[48,76,82,175,178,199,207],"proton":[50],"Larmor":[51],"frequency":[52],"7":[54],"Tesla.":[55],"WAND":[57,100,131,166,228],"then":[59],"mounted":[60],"system":[65],"easy":[67],"delivery":[68],"inside":[69],"confined":[70],"orifice.":[71],"Upon":[72],"reaching":[73],"region":[75,152,174,206],"interest,":[77],"it":[78,182],"unfolded":[80],"out":[81],"sheath":[84],"tube":[85],"increase":[87],"its":[88,126,134,139],"size.":[90],"Magnetic":[91],"(MR)":[93],"imaging":[94],"experiments":[95],"without":[98],"are":[101],"performed":[102],"both":[103],"in":[104,109,125,138,159,169,172,243],"water":[106],"phantom":[107],"live":[111,180],"rat":[112],"evaluate":[114],"WAND's":[116,213,221],"advantage.":[118],"Expanded":[119],"from":[120,211],"3":[122],"mm":[123,158,201],"diameter":[124],"folded":[127],"state,":[128],"this":[129],"can":[132],"change":[133],"width":[135],"by":[136,194,215],">100%":[137],"inflated":[140],"state":[141],"least":[144,186],"6":[145],"mm,":[146],"leading":[147],"sensitive":[150],"detection":[151],"extending":[153],"up":[155],"20":[157],"transverse":[161],"direction.":[162],"When":[163],"placed":[168],"an":[170],"artery":[171],"kidney":[177],"rat,":[181],"could":[183,229],"achieve":[184],"10-fold":[188],"SNR":[189],"gain":[190],"over":[191],"images":[192],"acquired":[193],"standard":[196],"external":[197],"22":[200],"diameter,":[202],"even":[203],"though":[204],"interest":[208],"separated":[210],"surface":[214],"distance":[217],"larger":[218],"than":[219],"own":[222],"width.":[223],"proposed":[225],"significantly":[230],"enlarge":[231],"MR":[236],"in-vivo,":[239],"enabling":[240],"versatile":[241],"applications":[242],"interventional":[244],"MRI.":[245]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}