{"id":"https://openalex.org/W2906529025","doi":"https://doi.org/10.1109/tbcas.2018.2888996","title":"Two-Wired Current Modulator Active Electrode for Ambulatory Biosignal Recording","display_name":"Two-Wired Current Modulator Active Electrode for Ambulatory Biosignal Recording","publication_year":2018,"publication_date":"2018-01-01","ids":{"openalex":"https://openalex.org/W2906529025","doi":"https://doi.org/10.1109/tbcas.2018.2888996","mag":"2906529025","pmid":"https://pubmed.ncbi.nlm.nih.gov/30575548"},"language":"en","primary_location":{"id":"doi:10.1109/tbcas.2018.2888996","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbcas.2018.2888996","pdf_url":null,"source":{"id":"https://openalex.org/S80299757","display_name":"IEEE Transactions on Biomedical Circuits and Systems","issn_l":"1932-4545","issn":["1932-4545","1940-9990"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Circuits and Systems","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5043720700","display_name":"Ali Pourahmad","orcid":null},"institutions":[{"id":"https://openalex.org/I170013655","display_name":"Isfahan University of Technology","ror":"https://ror.org/00af3sa43","country_code":"IR","type":"education","lineage":["https://openalex.org/I170013655"]}],"countries":["IR"],"is_corresponding":true,"raw_author_name":"Ali Pourahmad","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Isfahan University of Technology, Isfahan, Iran"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Isfahan University of Technology, Isfahan, Iran","institution_ids":["https://openalex.org/I170013655"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5027584373","display_name":"Rasoul Dehghani","orcid":"https://orcid.org/0000-0003-3790-1454"},"institutions":[{"id":"https://openalex.org/I170013655","display_name":"Isfahan University of Technology","ror":"https://ror.org/00af3sa43","country_code":"IR","type":"education","lineage":["https://openalex.org/I170013655"]}],"countries":["IR"],"is_corresponding":false,"raw_author_name":"Rasoul Dehghani","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Isfahan University of Technology, Isfahan, Iran"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Isfahan University of Technology, Isfahan, Iran","institution_ids":["https://openalex.org/I170013655"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5043720700"],"corresponding_institution_ids":["https://openalex.org/I170013655"],"apc_list":null,"apc_paid":null,"fwci":0.3269,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.58340193,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":"13","issue":"1","first_page":"1","last_page":"1"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11601","display_name":"Neuroscience and Neural Engineering","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2804","display_name":"Cellular and Molecular Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/preamplifier","display_name":"Preamplifier","score":0.7025159001350403},{"id":"https://openalex.org/keywords/common-mode-rejection-ratio","display_name":"Common-mode rejection ratio","score":0.6534699201583862},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.5753249526023865},{"id":"https://openalex.org/keywords/common-mode-signal","display_name":"Common-mode signal","score":0.5245923399925232},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.49714186787605286},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.4846130311489105},{"id":"https://openalex.org/keywords/operational-amplifier","display_name":"Operational amplifier","score":0.47302958369255066},{"id":"https://openalex.org/keywords/settling-time","display_name":"Settling time","score":0.4547036588191986},{"id":"https://openalex.org/keywords/amplifier","display_name":"Amplifier","score":0.4433189332485199},{"id":"https://openalex.org/keywords/current-source","display_name":"Current source","score":0.4427463710308075},{"id":"https://openalex.org/keywords/biosignal","display_name":"Biosignal","score":0.4287072420120239},{"id":"https://openalex.org/keywords/noise","display_name":"Noise (video)","score":0.411772757768631},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.3867107629776001},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.33702385425567627},{"id":"https://openalex.org/keywords/digital-signal-processing","display_name":"Digital signal processing","score":0.12054574489593506},{"id":"https://openalex.org/keywords/analog-signal","display_name":"Analog signal","score":0.11692595481872559},{"id":"https://openalex.org/keywords/cmos","display_name":"CMOS","score":0.11339855194091797},{"id":"https://openalex.org/keywords/step-response","display_name":"Step response","score":0.09438523650169373}],"concepts":[{"id":"https://openalex.org/C14245642","wikidata":"https://www.wikidata.org/wiki/Q399804","display_name":"Preamplifier","level":4,"score":0.7025159001350403},{"id":"https://openalex.org/C102309569","wikidata":"https://www.wikidata.org/wiki/Q1244941","display_name":"Common-mode rejection ratio","level":5,"score":0.6534699201583862},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5753249526023865},{"id":"https://openalex.org/C189714311","wikidata":"https://www.wikidata.org/wiki/Q1530371","display_name":"Common-mode signal","level":4,"score":0.5245923399925232},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.49714186787605286},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4846130311489105},{"id":"https://openalex.org/C145366948","wikidata":"https://www.wikidata.org/wiki/Q178947","display_name":"Operational amplifier","level":4,"score":0.47302958369255066},{"id":"https://openalex.org/C14781684","wikidata":"https://www.wikidata.org/wiki/Q3983320","display_name":"Settling time","level":3,"score":0.4547036588191986},{"id":"https://openalex.org/C194257627","wikidata":"https://www.wikidata.org/wiki/Q211554","display_name":"Amplifier","level":3,"score":0.4433189332485199},{"id":"https://openalex.org/C2781331714","wikidata":"https://www.wikidata.org/wiki/Q1163768","display_name":"Current source","level":3,"score":0.4427463710308075},{"id":"https://openalex.org/C2779055241","wikidata":"https://www.wikidata.org/wiki/Q644240","display_name":"Biosignal","level":3,"score":0.4287072420120239},{"id":"https://openalex.org/C99498987","wikidata":"https://www.wikidata.org/wiki/Q2210247","display_name":"Noise (video)","level":3,"score":0.411772757768631},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3867107629776001},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.33702385425567627},{"id":"https://openalex.org/C84462506","wikidata":"https://www.wikidata.org/wiki/Q173142","display_name":"Digital signal processing","level":2,"score":0.12054574489593506},{"id":"https://openalex.org/C13412647","wikidata":"https://www.wikidata.org/wiki/Q174948","display_name":"Analog signal","level":3,"score":0.11692595481872559},{"id":"https://openalex.org/C46362747","wikidata":"https://www.wikidata.org/wiki/Q173431","display_name":"CMOS","level":2,"score":0.11339855194091797},{"id":"https://openalex.org/C160030872","wikidata":"https://www.wikidata.org/wiki/Q2142864","display_name":"Step response","level":2,"score":0.09438523650169373},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.0},{"id":"https://openalex.org/C106131492","wikidata":"https://www.wikidata.org/wiki/Q3072260","display_name":"Filter (signal processing)","level":2,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C115961682","wikidata":"https://www.wikidata.org/wiki/Q860623","display_name":"Image (mathematics)","level":2,"score":0.0}],"mesh":[{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000669","descriptor_name":"Amplifiers, Electronic","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000669","descriptor_name":"Amplifiers, Electronic","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000669","descriptor_name":"Amplifiers, Electronic","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004560","descriptor_name":"Electricity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004560","descriptor_name":"Electricity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004560","descriptor_name":"Electricity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D004566","descriptor_name":"Electrodes","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004566","descriptor_name":"Electrodes","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004566","descriptor_name":"Electrodes","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004569","descriptor_name":"Electroencephalography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D004569","descriptor_name":"Electroencephalography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D004569","descriptor_name":"Electroencephalography","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D016138","descriptor_name":"Walking","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D016138","descriptor_name":"Walking","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D016138","descriptor_name":"Walking","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/tbcas.2018.2888996","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbcas.2018.2888996","pdf_url":null,"source":{"id":"https://openalex.org/S80299757","display_name":"IEEE Transactions on Biomedical Circuits and Systems","issn_l":"1932-4545","issn":["1932-4545","1940-9990"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Circuits and Systems","raw_type":"journal-article"},{"id":"pmid:30575548","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/30575548","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on biomedical circuits and systems","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8399999737739563}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":31,"referenced_works":["https://openalex.org/W34787404","https://openalex.org/W1943579973","https://openalex.org/W1969122934","https://openalex.org/W1990491739","https://openalex.org/W2014359522","https://openalex.org/W2035773773","https://openalex.org/W2046646175","https://openalex.org/W2060841640","https://openalex.org/W2061778814","https://openalex.org/W2071680666","https://openalex.org/W2072016585","https://openalex.org/W2076703967","https://openalex.org/W2083295694","https://openalex.org/W2098841319","https://openalex.org/W2101051970","https://openalex.org/W2109073090","https://openalex.org/W2112983600","https://openalex.org/W2121524565","https://openalex.org/W2122617960","https://openalex.org/W2125927307","https://openalex.org/W2126390573","https://openalex.org/W2131368080","https://openalex.org/W2152125115","https://openalex.org/W2159318368","https://openalex.org/W2296106309","https://openalex.org/W2332845049","https://openalex.org/W2496795132","https://openalex.org/W2549960523","https://openalex.org/W2794264416","https://openalex.org/W2801295417","https://openalex.org/W6723634125"],"related_works":["https://openalex.org/W2978924041","https://openalex.org/W2133205749","https://openalex.org/W1529471020","https://openalex.org/W2372770890","https://openalex.org/W3016853352","https://openalex.org/W2901068794","https://openalex.org/W2106859418","https://openalex.org/W2439880471","https://openalex.org/W2107565757","https://openalex.org/W2980282472"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"an":[3,33,154],"innovative":[4],"current":[5,41,67],"modulator":[6],"active":[7],"electrode":[8,95],"(CMAE)":[9],"with":[10,56,66,134,169],"only":[11,57],"two":[12,48,58],"outgoing":[13],"wires":[14],"that":[15],"reduces":[16],"cost":[17],"and":[18,63,72,107,116],"complexity":[19],"of":[20,69,87,104],"wearable":[21],"bioamplifiers":[22],"based":[23],"on":[24],"dry":[25],"electrodes.":[26],"The":[27,51,76,140],"CMAE":[28,52],"can":[29],"be":[30],"considered":[31],"as":[32],"operational":[34],"transconductance":[35],"amplifier,":[36],"which":[37,93,159],"modulates":[38],"the":[39,88,105,145,161,171],"supply":[40,49],"by":[42,152],"input":[43],"voltage":[44],"signal":[45],"through":[46],"its":[47],"rails.":[50],"prototype":[53],"is":[54,138,149],"implemented":[55],"discrete":[59],"op-amps":[60],"for":[61],"ECG":[62,106],"EEG":[64,108],"recording":[65],"consumption":[68],"60":[70],"\u03bcA":[71],"100":[73],"\u03bcA,":[74],"respectively.":[75],"CMAE's":[77],"built-in":[78],"preamplifier":[79],"has":[80],"utilized":[81],"a":[82],"dc":[83,90],"feedback":[84],"loop,":[85,92],"instead":[86],"conventional":[89],"servo":[91],"suppresses":[94],"offset":[96],"in":[97,121],"almost":[98],"rail-to-rail.":[99],"Total":[100],"input-referred":[101],"noise":[102,142,157],"voltages":[103],"type":[109],"CMAEs":[110],"are":[111],"3.9":[112],"\u03bcV[Formula:":[113],"see":[114],"text]":[115],"0.7":[117],"\u03bcV":[118],"<sub>RMS</sub>,":[119],"respectively,":[120],"0.5-100":[122],"Hz":[123],"bandwidth.":[124],"By":[125],"using":[126,153],"bipolar":[127],"pseudoresistors,":[128],"sub-hertz":[129],"high-pass":[130],"corner":[131],"frequency":[132],"but":[133],"fast":[135],"settling":[136],"time":[137],"achieved.":[139],"common-mode":[141,162],"due":[143],"to":[144,166],"disparate":[146],"channels":[147],"imbalances":[148],"digitally":[150],"rejected":[151],"online":[155],"adaptive":[156],"canceler,":[158],"boosts":[160],"rejection":[163],"ratio":[164],"up":[165],"120":[167],"dB":[168],"assisting":[170],"driven":[172],"right":[173],"leg":[174],"circuit.":[175]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2019,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
