{"id":"https://openalex.org/W2909461058","doi":"https://doi.org/10.1109/tbcas.2018.2887178","title":"Guest Editorial Special Issue on Advances and Open Challenges for Integrated Circuits Detecting Bio Molecules","display_name":"Guest Editorial Special Issue on Advances and Open Challenges for Integrated Circuits Detecting Bio Molecules","publication_year":2018,"publication_date":"2018-12-01","ids":{"openalex":"https://openalex.org/W2909461058","doi":"https://doi.org/10.1109/tbcas.2018.2887178","mag":"2909461058"},"language":"en","primary_location":{"id":"doi:10.1109/tbcas.2018.2887178","is_oa":true,"landing_page_url":"https://doi.org/10.1109/tbcas.2018.2887178","pdf_url":"https://ieeexplore.ieee.org/ielx7/4156126/8599184/08599186.pdf","source":{"id":"https://openalex.org/S80299757","display_name":"IEEE Transactions on Biomedical Circuits and Systems","issn_l":"1932-4545","issn":["1932-4545","1940-9990"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Circuits and Systems","raw_type":"journal-article"},"type":"editorial","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"bronze","oa_url":"https://ieeexplore.ieee.org/ielx7/4156126/8599184/08599186.pdf","any_repository_has_fulltext":false},"authorships":[],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":"12","issue":"6","first_page":"1334","last_page":"1336"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11601","display_name":"Neuroscience and Neural Engineering","score":0.9782000184059143,"subfield":{"id":"https://openalex.org/subfields/2804","display_name":"Cellular and Molecular Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},"topics":[{"id":"https://openalex.org/T11601","display_name":"Neuroscience and Neural Engineering","score":0.9782000184059143,"subfield":{"id":"https://openalex.org/subfields/2804","display_name":"Cellular and Molecular Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":0.9660000205039978,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10412","display_name":"Microfluidic and Capillary Electrophoresis Applications","score":0.9343000054359436,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electronic-circuit","display_name":"Electronic circuit","score":0.501054048538208},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.48205646872520447},{"id":"https://openalex.org/keywords/nanotechnology","display_name":"Nanotechnology","score":0.4115801155567169},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2807854413986206},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.27103668451309204},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.2368898093700409}],"concepts":[{"id":"https://openalex.org/C134146338","wikidata":"https://www.wikidata.org/wiki/Q1815901","display_name":"Electronic circuit","level":2,"score":0.501054048538208},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.48205646872520447},{"id":"https://openalex.org/C171250308","wikidata":"https://www.wikidata.org/wiki/Q11468","display_name":"Nanotechnology","level":1,"score":0.4115801155567169},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2807854413986206},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.27103668451309204},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.2368898093700409}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tbcas.2018.2887178","is_oa":true,"landing_page_url":"https://doi.org/10.1109/tbcas.2018.2887178","pdf_url":"https://ieeexplore.ieee.org/ielx7/4156126/8599184/08599186.pdf","source":{"id":"https://openalex.org/S80299757","display_name":"IEEE Transactions on Biomedical Circuits and Systems","issn_l":"1932-4545","issn":["1932-4545","1940-9990"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Circuits and Systems","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.1109/tbcas.2018.2887178","is_oa":true,"landing_page_url":"https://doi.org/10.1109/tbcas.2018.2887178","pdf_url":"https://ieeexplore.ieee.org/ielx7/4156126/8599184/08599186.pdf","source":{"id":"https://openalex.org/S80299757","display_name":"IEEE Transactions on Biomedical Circuits and Systems","issn_l":"1932-4545","issn":["1932-4545","1940-9990"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Circuits and Systems","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.550000011920929}],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2909461058.pdf","grobid_xml":"https://content.openalex.org/works/W2909461058.grobid-xml"},"referenced_works_count":1,"referenced_works":["https://openalex.org/W4289421475"],"related_works":["https://openalex.org/W2899084033","https://openalex.org/W2748952813","https://openalex.org/W2390279801","https://openalex.org/W2358668433","https://openalex.org/W2376932109","https://openalex.org/W2382290278","https://openalex.org/W2350741829","https://openalex.org/W2130043461","https://openalex.org/W2530322880","https://openalex.org/W1596801655"],"abstract_inverted_index":{"The":[0],"four":[1],"articles":[2],"in":[3,44,49,52,129,162],"this":[4],"special":[5],"section":[6],"focus":[7],"on":[8,124],"multidisciplinary":[9],"advancements":[10],"for":[11,20,82,155,173,183,188,207,221],"CMOS":[12,157],"integrated":[13,21,42,123],"circuit":[14,59],"technology-based":[15],"solutions.":[16],"Specially,":[17],"examines":[18],"advances":[19],"circuits":[22,43],"that":[23],"detect":[24],"biomolecules.":[25],"Despite":[26],"the":[27,39,55,61,130,204],"continuing":[28],"convergence":[29],"of":[30,41,57,119,132,147,197,212],"microelectronics":[31],"with":[32,89,139,164,218],"biomedicine,":[33],"important":[34,229],"technical":[35,230],"challenges":[36,193],"still":[37],"constrain":[38],"deployment":[40],"microanalytical":[45],"devices,":[46],"operating":[47],"both":[48,182],"vivo":[50],"and":[51,68,86,110,135,150,187,201,214,224],"vitro.":[53],"From":[54],"standpoint":[56],"electronic":[58],"design,":[60],"trade-offs":[62],"between":[63],"resolution":[64],"(noise),":[65],"area":[66,112],"(cost),":[67],"power":[69,108],"dissipation":[70,109],"need":[71,169],"to":[72,159,170],"be":[73,160,171],"carefully":[74],"optimized.":[75],"These":[76],"tradeoffs,":[77],"while":[78],"familiar,":[79],"are":[80,113,122,153,180],"crucial":[81],"endowing":[83],"portable,":[84],"wearable,":[85],"implantable":[87],"devices":[88],"high":[90,198],"sensitivity.":[91],"Some":[92],"applications":[93],"prioritize":[94],"ultra":[95],"low":[96],"noise,":[97],"such":[98],"as":[99,128],"single-biomolecule":[100],"detection":[101],"using":[102],"nanopore":[103],"sensors.":[104],"In":[105],"other":[106],"spaces,":[107],"die":[111],"clearly":[114],"major":[115],"constraints":[116],"when":[117],"thousands":[118],"sensing":[120],"channels":[121],"a":[125,144],"single":[126],"chip,":[127],"case":[131],"image":[133],"sensors":[134],"electrophysiology":[136],"arrays":[137],"interfacing":[138],"live":[140],"tissue.":[141],"Secondly,":[142],"from":[143],"system-level":[145],"point":[146],"view,":[148],"reliable":[149],"scalable":[151],"solutions":[152],"required":[154],"packaging":[156],"chips":[158],"used":[161],"contact":[163],"liquid":[165],"samples.":[166],"Fabrication":[167],"approaches":[168],"found":[172],"creating":[174],"chip-to-liquid":[175],"interfaces":[176],"(micro-tomacro":[177],"scale),":[178],"which":[179],"feasible":[181],"small-scale":[184],"academic":[185],"prototypes":[186],"high-volume":[189],"manufacturing.":[190],"Other":[191],"perennial":[192],"include":[194],"post-silicon":[195],"fabrication":[196],"performance":[199],"transducers":[200],"electrodes.":[202],"Finally,":[203],"different":[205],"avenues":[206],"monolithic":[208],"or":[209],"hybrid":[210],"integration":[211],"multichannel":[213],"low-noise":[215],"analog":[216],"front-ends":[217],"digital":[219],"back-ends":[220],"data":[222],"processing":[223],"wireless":[225],"communication":[226],"circuitry":[227],"pose":[228],"design":[231],"challenges.":[232]},"counts_by_year":[],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
