{"id":"https://openalex.org/W2899966502","doi":"https://doi.org/10.1109/tbcas.2018.2879818","title":"Electronics of a Wearable ECG with Level Crossing Sampling and Human Body Communication","display_name":"Electronics of a Wearable ECG with Level Crossing Sampling and Human Body Communication","publication_year":2018,"publication_date":"2018-01-01","ids":{"openalex":"https://openalex.org/W2899966502","doi":"https://doi.org/10.1109/tbcas.2018.2879818","mag":"2899966502","pmid":"https://pubmed.ncbi.nlm.nih.gov/30418883"},"language":"en","primary_location":{"id":"doi:10.1109/tbcas.2018.2879818","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbcas.2018.2879818","pdf_url":null,"source":{"id":"https://openalex.org/S80299757","display_name":"IEEE Transactions on Biomedical Circuits and Systems","issn_l":"1932-4545","issn":["1932-4545","1940-9990"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Circuits and Systems","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5010341431","display_name":"Jinxi Xiang","orcid":"https://orcid.org/0000-0002-5476-3690"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Jinxi Xiang","raw_affiliation_strings":["State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, China"],"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101526463","display_name":"Yonggui Dong","orcid":"https://orcid.org/0000-0003-3469-674X"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yonggui Dong","raw_affiliation_strings":["State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, China"],"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5069941189","display_name":"Xiaohui Xue","orcid":"https://orcid.org/0000-0003-3719-8391"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xiaohui Xue","raw_affiliation_strings":["State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, China"],"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5030157501","display_name":"Hao Xiong","orcid":"https://orcid.org/0000-0001-5479-7754"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Hao Xiong","raw_affiliation_strings":["State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, China"],"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5010341431"],"corresponding_institution_ids":["https://openalex.org/I99065089"],"apc_list":null,"apc_paid":null,"fwci":1.5254,"has_fulltext":false,"cited_by_count":30,"citation_normalized_percentile":{"value":0.81889924,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":95,"max":99},"biblio":{"volume":"13","issue":"1","first_page":"1","last_page":"1"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11932","display_name":"Wireless Body Area Networks","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11932","display_name":"Wireless Body Area Networks","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13052","display_name":"Molecular Communication and Nanonetworks","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9958999752998352,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/heartbeat","display_name":"Heartbeat","score":0.5252066254615784},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.5245711803436279},{"id":"https://openalex.org/keywords/sampling","display_name":"Sampling (signal processing)","score":0.5228864550590515},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5083093047142029},{"id":"https://openalex.org/keywords/keying","display_name":"Keying","score":0.495842307806015},{"id":"https://openalex.org/keywords/electrical-impedance","display_name":"Electrical impedance","score":0.4539002776145935},{"id":"https://openalex.org/keywords/waveform","display_name":"Waveform","score":0.45344358682632446},{"id":"https://openalex.org/keywords/wearable-computer","display_name":"Wearable computer","score":0.4432711601257324},{"id":"https://openalex.org/keywords/electronics","display_name":"Electronics","score":0.42468786239624023},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.42020201683044434},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.34388208389282227},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.3323817253112793},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.22321033477783203},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.16710251569747925},{"id":"https://openalex.org/keywords/detector","display_name":"Detector","score":0.15107378363609314},{"id":"https://openalex.org/keywords/radar","display_name":"Radar","score":0.14126163721084595},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.11307016015052795}],"concepts":[{"id":"https://openalex.org/C13852961","wikidata":"https://www.wikidata.org/wiki/Q17021880","display_name":"Heartbeat","level":2,"score":0.5252066254615784},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.5245711803436279},{"id":"https://openalex.org/C140779682","wikidata":"https://www.wikidata.org/wiki/Q210868","display_name":"Sampling (signal processing)","level":3,"score":0.5228864550590515},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5083093047142029},{"id":"https://openalex.org/C2776542216","wikidata":"https://www.wikidata.org/wiki/Q6398306","display_name":"Keying","level":2,"score":0.495842307806015},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.4539002776145935},{"id":"https://openalex.org/C197424946","wikidata":"https://www.wikidata.org/wiki/Q1165717","display_name":"Waveform","level":3,"score":0.45344358682632446},{"id":"https://openalex.org/C150594956","wikidata":"https://www.wikidata.org/wiki/Q1334829","display_name":"Wearable computer","level":2,"score":0.4432711601257324},{"id":"https://openalex.org/C138331895","wikidata":"https://www.wikidata.org/wiki/Q11650","display_name":"Electronics","level":2,"score":0.42468786239624023},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.42020201683044434},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.34388208389282227},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.3323817253112793},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.22321033477783203},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.16710251569747925},{"id":"https://openalex.org/C94915269","wikidata":"https://www.wikidata.org/wiki/Q1834857","display_name":"Detector","level":2,"score":0.15107378363609314},{"id":"https://openalex.org/C554190296","wikidata":"https://www.wikidata.org/wiki/Q47528","display_name":"Radar","level":2,"score":0.14126163721084595},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.11307016015052795},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D000076251","descriptor_name":"Wearable Electronic Devices","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000076251","descriptor_name":"Wearable Electronic Devices","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000076251","descriptor_name":"Wearable Electronic Devices","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000328","descriptor_name":"Adult","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000328","descriptor_name":"Adult","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000328","descriptor_name":"Adult","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D003142","descriptor_name":"Communication","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D003142","descriptor_name":"Communication","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D003142","descriptor_name":"Communication","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004560","descriptor_name":"Electricity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004560","descriptor_name":"Electricity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004560","descriptor_name":"Electricity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004562","descriptor_name":"Electrocardiography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008297","descriptor_name":"Male","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008297","descriptor_name":"Male","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008297","descriptor_name":"Male","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D009068","descriptor_name":"Movement","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D009068","descriptor_name":"Movement","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D009068","descriptor_name":"Movement","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012119","descriptor_name":"Respiration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012119","descriptor_name":"Respiration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012119","descriptor_name":"Respiration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D018594","descriptor_name":"Human Body","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D018594","descriptor_name":"Human Body","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D018594","descriptor_name":"Human Body","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D055815","descriptor_name":"Young Adult","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D055815","descriptor_name":"Young Adult","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D055815","descriptor_name":"Young Adult","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D058067","descriptor_name":"Wavelet Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D058067","descriptor_name":"Wavelet Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D058067","descriptor_name":"Wavelet Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/tbcas.2018.2879818","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbcas.2018.2879818","pdf_url":null,"source":{"id":"https://openalex.org/S80299757","display_name":"IEEE Transactions on Biomedical Circuits and Systems","issn_l":"1932-4545","issn":["1932-4545","1940-9990"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Circuits and Systems","raw_type":"journal-article"},{"id":"pmid:30418883","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/30418883","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on biomedical circuits and systems","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.8600000143051147,"id":"https://metadata.un.org/sdg/7"}],"awards":[{"id":"https://openalex.org/G3721865172","display_name":null,"funder_award_id":"61671270","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":36,"referenced_works":["https://openalex.org/W1563549564","https://openalex.org/W1971513336","https://openalex.org/W1985529456","https://openalex.org/W1986650185","https://openalex.org/W2046480837","https://openalex.org/W2070055649","https://openalex.org/W2085715982","https://openalex.org/W2095398224","https://openalex.org/W2101899971","https://openalex.org/W2108402465","https://openalex.org/W2110134128","https://openalex.org/W2112759302","https://openalex.org/W2114799023","https://openalex.org/W2126390573","https://openalex.org/W2134351284","https://openalex.org/W2143516309","https://openalex.org/W2150580621","https://openalex.org/W2157214632","https://openalex.org/W2192492215","https://openalex.org/W2314020336","https://openalex.org/W2395572751","https://openalex.org/W2564349130","https://openalex.org/W2570842125","https://openalex.org/W2571193586","https://openalex.org/W2586356224","https://openalex.org/W2616560283","https://openalex.org/W2620529027","https://openalex.org/W2624775385","https://openalex.org/W2725350978","https://openalex.org/W2740320639","https://openalex.org/W2744970336","https://openalex.org/W2754518759","https://openalex.org/W2790811344","https://openalex.org/W2793746235","https://openalex.org/W3102346569","https://openalex.org/W6731762948"],"related_works":["https://openalex.org/W4385543909","https://openalex.org/W3039320222","https://openalex.org/W3199640442","https://openalex.org/W1898280036","https://openalex.org/W2315807364","https://openalex.org/W2382278803","https://openalex.org/W2376695684","https://openalex.org/W2803040299","https://openalex.org/W2034075638","https://openalex.org/W1982967776"],"abstract_inverted_index":{"In":[0,41],"this":[1],"paper,":[2],"the":[3,66,70,85,94,104,124,128,148,168,172,177],"human":[4,125],"body":[5,126],"communication":[6],"(HBC)":[7],"and":[8,120,141,171],"level":[9],"crossing":[10],"sampling":[11],"(LCS)":[12],"are":[13,31,113,180],"combined":[14],"to":[15,43,102,127],"design":[16],"electronics":[17],"for":[18],"a":[19,164],"wearable":[20],"electrocardiograph":[21],"(ECG).":[22],"The":[23,73,110,144,160],"ECG":[24,105,132,150,158],"signals":[25,45,106],"acquired":[26,149],"by":[27,79,115],"capacitively":[28],"coupled":[29],"electrodes":[30],"sampled":[32],"with":[33,59,84,99,137,155],"LCS":[34,90],"in":[35],"place":[36],"of":[37,69,176],"conventional":[38],"synchronous":[39],"sampling.":[40],"order":[42],"transmit":[44],"through":[46],"HBC":[47,71,74],"at":[48],"low":[49],"frequencies":[50],"(100":[51],"kHz,":[52],"1":[53],"MHz),":[54],"an":[55,116],"electric":[56,86],"field":[57,87],"sensor":[58],"high":[60],"input":[61],"impedance":[62],"is":[63,77,97,135],"adopted":[64],"as":[65],"front":[67],"end":[68],"receiver.":[72,129],"channel":[75],"gain":[76],"enhanced":[78],"more":[80],"than":[81],"30":[82],"dB":[83],"sensor.":[88],"An":[89],"structure":[91],"based":[92,166],"on":[93,167],"send-on-delta":[95],"concept":[96],"implemented":[98],"discrete":[100],"components":[101,140],"convert":[103],"into":[107],"binary":[108],"impulses.":[109],"converted":[111],"impulses":[112],"modulated":[114],"on-off":[117],"keying":[118],"modulator":[119],"then":[121],"transmitted":[122],"via":[123],"A":[130],"prototype":[131],"waist":[133],"belt":[134],"developed":[136],"commercially":[138],"available":[139],"experimentally":[142],"evaluated.":[143],"results":[145],"indicate":[146],"that":[147],"waveforms":[151],"exhibit":[152],"good":[153],"agreement":[154],"regular":[156],"Ag/AgCl":[157],"methods.":[159],"heartbeat":[161],"detection":[162],"using":[163],"technique":[165],"Kadane's":[169],"algorithm":[170],"power":[173],"consumption":[174],"performance":[175],"proposed":[178],"system":[179],"also":[181],"discussed.":[182]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":4},{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":7},{"year":2021,"cited_by_count":5},{"year":2020,"cited_by_count":6},{"year":2019,"cited_by_count":3}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
