{"id":"https://openalex.org/W2885036086","doi":"https://doi.org/10.1109/tbcas.2018.2832172","title":"A Parasitic Insensitive Catheter-Based Capacitive Force Sensor for Cardiovascular Diagnosis","display_name":"A Parasitic Insensitive Catheter-Based Capacitive Force Sensor for Cardiovascular Diagnosis","publication_year":2018,"publication_date":"2018-06-15","ids":{"openalex":"https://openalex.org/W2885036086","doi":"https://doi.org/10.1109/tbcas.2018.2832172","mag":"2885036086","pmid":"https://pubmed.ncbi.nlm.nih.gov/29994663"},"language":"en","primary_location":{"id":"doi:10.1109/tbcas.2018.2832172","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbcas.2018.2832172","pdf_url":null,"source":{"id":"https://openalex.org/S80299757","display_name":"IEEE Transactions on Biomedical Circuits and Systems","issn_l":"1932-4545","issn":["1932-4545","1940-9990"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Circuits and Systems","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Sangkuk Jeon","orcid":"https://orcid.org/0000-0002-0436-1036"},"institutions":[{"id":"https://openalex.org/I193775966","display_name":"Yonsei University","ror":"https://ror.org/01wjejq96","country_code":"KR","type":"education","lineage":["https://openalex.org/I193775966"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Sangkuk Jeon","raw_affiliation_strings":["Department of Electrical and Electronic Engineering, Yonsei University, Seoul, South Korea"],"raw_orcid":"https://orcid.org/0000-0002-0436-1036","affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronic Engineering, Yonsei University, Seoul, South Korea","institution_ids":["https://openalex.org/I193775966"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101414227","display_name":"Ji\u2010Yong Lee","orcid":"https://orcid.org/0000-0002-3858-0421"},"institutions":[{"id":"https://openalex.org/I193775966","display_name":"Yonsei University","ror":"https://ror.org/01wjejq96","country_code":"KR","type":"education","lineage":["https://openalex.org/I193775966"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"JiYong Lee","raw_affiliation_strings":["Department of Mechanical Engineering, Yonsei University, Seoul, South Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Mechanical Engineering, Yonsei University, Seoul, South Korea","institution_ids":["https://openalex.org/I193775966"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101526540","display_name":"Hyunseok Hwang","orcid":"https://orcid.org/0000-0003-3052-3585"},"institutions":[{"id":"https://openalex.org/I193775966","display_name":"Yonsei University","ror":"https://ror.org/01wjejq96","country_code":"KR","type":"education","lineage":["https://openalex.org/I193775966"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Hyunseok Hwang","raw_affiliation_strings":["Department of Electrical and Electronic Engineering, Yonsei University, Seoul, South Korea"],"raw_orcid":"https://orcid.org/0000-0003-3052-3585","affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronic Engineering, Yonsei University, Seoul, South Korea","institution_ids":["https://openalex.org/I193775966"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5047810890","display_name":"WonHyoung Ryu","orcid":"https://orcid.org/0000-0002-1480-2245"},"institutions":[{"id":"https://openalex.org/I193775966","display_name":"Yonsei University","ror":"https://ror.org/01wjejq96","country_code":"KR","type":"education","lineage":["https://openalex.org/I193775966"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"WonHyoung Ryu","raw_affiliation_strings":["Department of Mechanical Engineering, Yonsei University, Seoul, South Korea"],"raw_orcid":"https://orcid.org/0000-0002-1480-2245","affiliations":[{"raw_affiliation_string":"Department of Mechanical Engineering, Yonsei University, Seoul, South Korea","institution_ids":["https://openalex.org/I193775966"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5088759343","display_name":"Youngcheol Chae","orcid":"https://orcid.org/0000-0002-1618-169X"},"institutions":[{"id":"https://openalex.org/I193775966","display_name":"Yonsei University","ror":"https://ror.org/01wjejq96","country_code":"KR","type":"education","lineage":["https://openalex.org/I193775966"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Youngcheol Chae","raw_affiliation_strings":["Department of Electrical and Electronic Engineering, Yonsei University, Seoul, South Korea"],"raw_orcid":"https://orcid.org/0000-0002-1618-169X","affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronic Engineering, Yonsei University, Seoul, South Korea","institution_ids":["https://openalex.org/I193775966"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I193775966"],"apc_list":{"value":2645,"currency":"USD","value_usd":2645},"apc_paid":null,"fwci":0.6527,"has_fulltext":false,"cited_by_count":29,"citation_normalized_percentile":{"value":0.64568528,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":"12","issue":"4","first_page":"812","last_page":"823"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10338","display_name":"Advanced Sensor and Energy Harvesting Materials","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10338","display_name":"Advanced Sensor and Energy Harvesting Materials","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10784","display_name":"Muscle activation and electromyography studies","score":0.9969000220298767,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11230","display_name":"Innovative Energy Harvesting Technologies","score":0.995199978351593,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/capacitive-sensing","display_name":"Capacitive sensing","score":0.7720167636871338},{"id":"https://openalex.org/keywords/capacitance","display_name":"Capacitance","score":0.5575552582740784},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.4552357494831085},{"id":"https://openalex.org/keywords/capacitor","display_name":"Capacitor","score":0.4165516495704651},{"id":"https://openalex.org/keywords/parasitic-capacitance","display_name":"Parasitic capacitance","score":0.4104650318622589},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.36237579584121704},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.33722057938575745},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.329748272895813},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.21435731649398804},{"id":"https://openalex.org/keywords/quantum-mechanics","display_name":"Quantum mechanics","score":0.14789927005767822},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.12376117706298828},{"id":"https://openalex.org/keywords/electrode","display_name":"Electrode","score":0.11894223093986511}],"concepts":[{"id":"https://openalex.org/C206755178","wikidata":"https://www.wikidata.org/wiki/Q1131271","display_name":"Capacitive sensing","level":2,"score":0.7720167636871338},{"id":"https://openalex.org/C30066665","wikidata":"https://www.wikidata.org/wiki/Q164399","display_name":"Capacitance","level":3,"score":0.5575552582740784},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4552357494831085},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.4165516495704651},{"id":"https://openalex.org/C154318817","wikidata":"https://www.wikidata.org/wiki/Q2157249","display_name":"Parasitic capacitance","level":4,"score":0.4104650318622589},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.36237579584121704},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.33722057938575745},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.329748272895813},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.21435731649398804},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.14789927005767822},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.12376117706298828},{"id":"https://openalex.org/C17525397","wikidata":"https://www.wikidata.org/wiki/Q176140","display_name":"Electrode","level":2,"score":0.11894223093986511}],"mesh":[{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015374","descriptor_name":"Biosensing Techniques","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D015374","descriptor_name":"Biosensing Techniques","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D015374","descriptor_name":"Biosensing Techniques","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D025802","descriptor_name":"Electric Capacitance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D025802","descriptor_name":"Electric Capacitance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D025802","descriptor_name":"Electric Capacitance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D057785","descriptor_name":"Catheters","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D057785","descriptor_name":"Catheters","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D057785","descriptor_name":"Catheters","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true}],"locations_count":2,"locations":[{"id":"doi:10.1109/tbcas.2018.2832172","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbcas.2018.2832172","pdf_url":null,"source":{"id":"https://openalex.org/S80299757","display_name":"IEEE Transactions on Biomedical Circuits and Systems","issn_l":"1932-4545","issn":["1932-4545","1940-9990"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Circuits and Systems","raw_type":"journal-article"},{"id":"pmid:29994663","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/29994663","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on biomedical circuits and systems","raw_type":"Journal Article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320322120","display_name":"National Research Foundation of Korea","ror":"https://ror.org/013aysd81"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":21,"referenced_works":["https://openalex.org/W571512533","https://openalex.org/W1982340141","https://openalex.org/W1983309921","https://openalex.org/W1984534938","https://openalex.org/W1986149199","https://openalex.org/W1988290241","https://openalex.org/W1999937314","https://openalex.org/W2001214491","https://openalex.org/W2011898260","https://openalex.org/W2041793164","https://openalex.org/W2054544120","https://openalex.org/W2068752178","https://openalex.org/W2078554736","https://openalex.org/W2081009679","https://openalex.org/W2084408015","https://openalex.org/W2117345577","https://openalex.org/W2120200547","https://openalex.org/W2125065061","https://openalex.org/W2166944910","https://openalex.org/W2547526288","https://openalex.org/W3150891300"],"related_works":["https://openalex.org/W2348740411","https://openalex.org/W1966596465","https://openalex.org/W2051563071","https://openalex.org/W4386858602","https://openalex.org/W2337947459","https://openalex.org/W2080773395","https://openalex.org/W2118205267","https://openalex.org/W2099626417","https://openalex.org/W2019514496","https://openalex.org/W2085450379"],"abstract_inverted_index":{"This":[0,153],"paper":[1],"presents":[2],"a":[3,18,26,31,35,43,63,68,82,86,103,121,140,156,220],"catheter-based":[4],"capacitive":[5,45,216],"force":[6,13,104,157,217],"sensor":[7,14,39,46,99,123,179,210],"interface":[8,180,211],"for":[9],"cardiovascular":[10],"diagnosis.":[11],"The":[12,97,109,177,208],"is":[15,40,163,181],"implemented":[16],"on":[17],"flexible":[19],"printed":[20],"circuit":[21],"board":[22],"(FPCB)":[23],"substrate":[24],"with":[25,74,102,204],"force-sensitive":[27],"polydimethylsiloxane":[28],"(PDMS),":[29],"and":[30,85,124,133,192],"force-induced":[32],"change":[33],"in":[34,106,120,219],"capacitance":[36,58,135],"of":[37,62,93,117,130,137,148,159,196,215],"the":[38,50,55,90,94,128,134,169,172,193,213],"measured":[41,101],"by":[42,54,144],"precision":[44],"interface.":[47],"To":[48],"recover":[49],"performance":[51],"degradation":[52],"caused":[53],"large":[56],"parasitic":[57,69],"${\\rm":[59,76,114,149,173,184],"C}_{\\rm":[60,77,115,150,174,185],"P}$":[61,78,116,151,175,186],"long":[64],"catheter,":[65],"we":[66],"present":[67],"insensitive":[70,182],"analog":[71],"front-end":[72],"(AFE)":[73],"active":[75],"cancellation,":[79],"which":[80,162],"employs":[81],"charge":[83,95],"amplifier":[84],"negative":[87],"capacitor":[88],"at":[89],"virtual":[91],"ground":[92],"amplifier.":[96],"prototype":[98],"was":[100],"loader":[105],"whole":[107],"blood.":[108],"proposed":[110,178,209],"AFE":[111],"successfully":[112,202],"cancels":[113],"348":[118],"pF":[119],"0.9-m-long":[122],"measurement":[125],"results":[126],"show":[127],"SNR":[129],"53.8":[131],"dB":[132,142],"resolution":[136,158],"16":[138],"aF,":[139],"19.6":[141],"improvement":[143],"canceling":[145],"nonideal":[146],"effect":[147],".":[152],"corresponds":[154],"to":[155,168,183,189],"2.22":[160],"gf,":[161],"9.29":[164],"$\\times$":[165],"reduction":[166],"compared":[167],"work":[170],"without":[171],"cancellation.":[176],"from":[187],"hundreds":[188],"1-nF":[190],"level,":[191],"force-dependent":[194],"stiffness":[195],"two":[197],"different":[198],"tissues":[199],"has":[200],"been":[201],"distinguished":[203],"an":[205],"ex-vivo":[206],"experiment.":[207],"enables":[212],"integration":[214],"sensors":[218],"smart":[221],"catheter.":[222]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":7},{"year":2024,"cited_by_count":7},{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":4},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":2},{"year":2018,"cited_by_count":1}],"updated_date":"2026-08-21T09:56:20.448147","created_date":"2025-10-10T00:00:00"}
