{"id":"https://openalex.org/W2796250424","doi":"https://doi.org/10.1109/tbcas.2018.2812222","title":"A Multichannel Real-Time Bioimpedance Measurement Device for Pulse Wave Analysis","display_name":"A Multichannel Real-Time Bioimpedance Measurement Device for Pulse Wave Analysis","publication_year":2018,"publication_date":"2018-04-04","ids":{"openalex":"https://openalex.org/W2796250424","doi":"https://doi.org/10.1109/tbcas.2018.2812222","mag":"2796250424","pmid":"https://pubmed.ncbi.nlm.nih.gov/29877824"},"language":"en","primary_location":{"id":"doi:10.1109/tbcas.2018.2812222","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbcas.2018.2812222","pdf_url":null,"source":{"id":"https://openalex.org/S80299757","display_name":"IEEE Transactions on Biomedical Circuits and Systems","issn_l":"1932-4545","issn":["1932-4545","1940-9990"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Circuits and Systems","raw_type":"journal-article"},"type":"article","indexed_in":["arxiv","crossref","pubmed"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://arxiv.org/pdf/1902.09379","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Roman Kusche","orcid":"https://orcid.org/0000-0003-2925-7638"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Roman Kusche","raw_affiliation_strings":["Laboratory of Medical Electronics (LME), Luebeck University of Applied Sciences, Luebeck, Germany"],"raw_orcid":"https://orcid.org/0000-0003-2925-7638","affiliations":[{"raw_affiliation_string":"Laboratory of Medical Electronics (LME), Luebeck University of Applied Sciences, Luebeck, Germany","institution_ids":[]}]},{"author_position":"middle","author":{"id":null,"display_name":"Paula Klimach","orcid":null},"institutions":[{"id":"https://openalex.org/I9341345","display_name":"University of L\u00fcbeck","ror":"https://ror.org/00t3r8h32","country_code":"DE","type":"education","lineage":["https://openalex.org/I9341345"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Paula Klimach","raw_affiliation_strings":["Graduate School for Computing in Medicine and Life Sciences, University of Luebeck, Luebeck, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Graduate School for Computing in Medicine and Life Sciences, University of Luebeck, Luebeck, Germany","institution_ids":["https://openalex.org/I9341345"]}]},{"author_position":"last","author":{"id":null,"display_name":"Martin Ryschka","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Martin Ryschka","raw_affiliation_strings":["Laboratory of Medical Electronics (LME), Luebeck University of Applied Sciences, Luebeck, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Laboratory of Medical Electronics (LME), Luebeck University of Applied Sciences, Luebeck, Germany","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.02,"has_fulltext":false,"cited_by_count":40,"citation_normalized_percentile":{"value":0.87178655,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":99},"biblio":{"volume":"12","issue":"3","first_page":"614","last_page":"622"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":0.5965999960899353,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":0.5965999960899353,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12279","display_name":"Body Composition Measurement Techniques","score":0.24480000138282776,"subfield":{"id":"https://openalex.org/subfields/2737","display_name":"Physiology"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.08720000088214874,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/pulse","display_name":"Pulse (music)","score":0.6082000136375427},{"id":"https://openalex.org/keywords/electrical-impedance","display_name":"Electrical impedance","score":0.5964999794960022},{"id":"https://openalex.org/keywords/pulse-wave","display_name":"Pulse wave","score":0.5782999992370605},{"id":"https://openalex.org/keywords/pulse-wave-analysis","display_name":"Pulse Wave Analysis","score":0.5148000121116638},{"id":"https://openalex.org/keywords/system-of-measurement","display_name":"System of measurement","score":0.4300000071525574},{"id":"https://openalex.org/keywords/interface","display_name":"Interface (matter)","score":0.4169999957084656},{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.3330000042915344},{"id":"https://openalex.org/keywords/focused-impedance-measurement","display_name":"Focused Impedance Measurement","score":0.32019999623298645}],"concepts":[{"id":"https://openalex.org/C2780167933","wikidata":"https://www.wikidata.org/wiki/Q1550652","display_name":"Pulse (music)","level":3,"score":0.6082000136375427},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.5964999794960022},{"id":"https://openalex.org/C172321821","wikidata":"https://www.wikidata.org/wiki/Q7259685","display_name":"Pulse wave","level":3,"score":0.5782999992370605},{"id":"https://openalex.org/C2908916285","wikidata":"https://www.wikidata.org/wiki/Q2118022","display_name":"Pulse Wave Analysis","level":4,"score":0.5148000121116638},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.5044999718666077},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.44209998846054077},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.43149998784065247},{"id":"https://openalex.org/C37649242","wikidata":"https://www.wikidata.org/wiki/Q932268","display_name":"System of measurement","level":2,"score":0.4300000071525574},{"id":"https://openalex.org/C113843644","wikidata":"https://www.wikidata.org/wiki/Q901882","display_name":"Interface (matter)","level":4,"score":0.4169999957084656},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3896999955177307},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.3330000042915344},{"id":"https://openalex.org/C172066009","wikidata":"https://www.wikidata.org/wiki/Q5463955","display_name":"Focused Impedance Measurement","level":3,"score":0.32019999623298645},{"id":"https://openalex.org/C172674978","wikidata":"https://www.wikidata.org/wiki/Q1164612","display_name":"Characteristic impedance","level":3,"score":0.30169999599456787},{"id":"https://openalex.org/C204323151","wikidata":"https://www.wikidata.org/wiki/Q905424","display_name":"Range (aeronautics)","level":2,"score":0.2994999885559082},{"id":"https://openalex.org/C18762648","wikidata":"https://www.wikidata.org/wiki/Q42213","display_name":"Work (physics)","level":2,"score":0.2858000099658966},{"id":"https://openalex.org/C62646347","wikidata":"https://www.wikidata.org/wiki/Q2041172","display_name":"Measuring instrument","level":2,"score":0.2831999957561493},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.2827000021934509},{"id":"https://openalex.org/C2780009758","wikidata":"https://www.wikidata.org/wiki/Q6804172","display_name":"Measure (data warehouse)","level":2,"score":0.26589998602867126},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.2637999951839447},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.25999999046325684},{"id":"https://openalex.org/C134146338","wikidata":"https://www.wikidata.org/wiki/Q1815901","display_name":"Electronic circuit","level":2,"score":0.25780001282691956},{"id":"https://openalex.org/C163985040","wikidata":"https://www.wikidata.org/wiki/Q1172399","display_name":"Data acquisition","level":2,"score":0.2556000053882599},{"id":"https://openalex.org/C104267543","wikidata":"https://www.wikidata.org/wiki/Q208163","display_name":"Signal processing","level":3,"score":0.25360000133514404},{"id":"https://openalex.org/C92746544","wikidata":"https://www.wikidata.org/wiki/Q585184","display_name":"Pulse-width modulation","level":3,"score":0.2506999969482422},{"id":"https://openalex.org/C169150495","wikidata":"https://www.wikidata.org/wiki/Q7259675","display_name":"Pulse duration","level":3,"score":0.25049999356269836}],"mesh":[{"descriptor_ui":"D000328","descriptor_name":"Adult","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000328","descriptor_name":"Adult","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000328","descriptor_name":"Adult","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008297","descriptor_name":"Male","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008297","descriptor_name":"Male","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008297","descriptor_name":"Male","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D017097","descriptor_name":"Electric Impedance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D017097","descriptor_name":"Electric Impedance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D017097","descriptor_name":"Electric Impedance","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D063177","descriptor_name":"Pulse Wave Analysis","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D063177","descriptor_name":"Pulse Wave Analysis","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D063177","descriptor_name":"Pulse Wave Analysis","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D063177","descriptor_name":"Pulse Wave Analysis","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D063177","descriptor_name":"Pulse Wave Analysis","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D063177","descriptor_name":"Pulse Wave Analysis","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true}],"locations_count":3,"locations":[{"id":"doi:10.1109/tbcas.2018.2812222","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbcas.2018.2812222","pdf_url":null,"source":{"id":"https://openalex.org/S80299757","display_name":"IEEE Transactions on Biomedical Circuits and Systems","issn_l":"1932-4545","issn":["1932-4545","1940-9990"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Circuits and Systems","raw_type":"journal-article"},{"id":"pmid:29877824","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/29877824","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on biomedical circuits and systems","raw_type":null},{"id":"pmh:oai:arXiv.org:1902.09379","is_oa":true,"landing_page_url":"http://arxiv.org/abs/1902.09379","pdf_url":"https://arxiv.org/pdf/1902.09379","source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"text"}],"best_oa_location":{"id":"pmh:oai:arXiv.org:1902.09379","is_oa":true,"landing_page_url":"http://arxiv.org/abs/1902.09379","pdf_url":"https://arxiv.org/pdf/1902.09379","source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"text"},"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":23,"referenced_works":["https://openalex.org/W122349615","https://openalex.org/W154416618","https://openalex.org/W1600688475","https://openalex.org/W1974498692","https://openalex.org/W1988713876","https://openalex.org/W1998962655","https://openalex.org/W2016444890","https://openalex.org/W2018074094","https://openalex.org/W2029473249","https://openalex.org/W2046385949","https://openalex.org/W2066036954","https://openalex.org/W2078097192","https://openalex.org/W2114268392","https://openalex.org/W2123396611","https://openalex.org/W2125914602","https://openalex.org/W2129374966","https://openalex.org/W2131599914","https://openalex.org/W2138209376","https://openalex.org/W2151436842","https://openalex.org/W2153285753","https://openalex.org/W2170511544","https://openalex.org/W2506656022","https://openalex.org/W6759642882"],"related_works":[],"abstract_inverted_index":{"Pulse":[0],"wave":[1,20,157,184,192],"analysis":[2,158],"is":[3,82,150],"an":[4],"important":[5],"method":[6],"used":[7],"to":[8,29,56,62,99,116,175],"gather":[9],"information":[10],"about":[11],"the":[12,18,34,37,41,54,80,107,127,137,177,182,189],"cardiovascular":[13],"system.":[14],"Instead":[15],"of":[16,36,84,129,136,180],"detecting":[17],"pulse":[19,42,156,183,191],"via":[21,112,159],"pressure":[22],"sensors,":[23],"bioimpedance":[24,49,161],"measurements":[25,59,162],"can":[26],"be":[27],"performed":[28],"acquire":[30,57],"minuscule":[31],"changes":[32,147],"in":[33,94,132],"conductivity":[35],"tissue,":[38],"caused":[39],"by":[40],"wave.":[43],"This":[44],"work":[45],"presents":[46],"a":[47,69,75,91,95,117,170],"microcontroller-based":[48],"measurement":[50,72,167],"system,":[51],"which":[52],"has":[53],"capability":[55],"impedance":[58,146],"from":[60,97,169],"up":[61],"four":[63],"independent":[64],"channels":[65,131],"simultaneously.":[66],"By":[67],"combining":[68],"problem-specific":[70],"analog":[71],"circuit":[73],"with":[74,90],"24":[76],"bits":[77],"analog-to-digital":[78],"converter,":[79],"system":[81,138],"capable":[83],"acquiring":[85],"1000":[86],"impedances":[87],"per":[88],"second":[89],"signal-to-noise":[92],"ratio":[93],"range":[96],"92":[98],"96":[100],"dB.":[101],"For":[102],"data":[103,109,128],"storage":[104],"and":[105,125],"analysis,":[106],"digitized":[108],"are":[110,163,173],"sent":[111],"universal":[113],"serial":[114],"bus":[115],"host":[118],"PC.":[119],"A":[120],"graphical":[121],"user":[122],"interface":[123],"filters":[124],"plots":[126],"all":[130],"real-time.":[133],"The":[134],"performance":[135],"regarding":[139],"measuring":[140],"constant":[141],"impedances,":[142],"as":[143,145,186,188],"well":[144,187],"over":[148],"time":[149],"demonstrated.":[151],"Two":[152],"different":[153],"applications":[154],"for":[155],"multichannel":[160],"presented.":[164],"Additionally,":[165],"first":[166],"results":[168],"human":[171],"subject":[172],"shown":[174],"demonstrate":[176],"system's":[178],"applicability":[179],"analyzing":[181],"morphology":[185],"aortic":[190],"velocity.":[193]},"counts_by_year":[{"year":2025,"cited_by_count":6},{"year":2024,"cited_by_count":7},{"year":2023,"cited_by_count":5},{"year":2022,"cited_by_count":6},{"year":2021,"cited_by_count":7},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":4},{"year":2018,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2018-04-13T00:00:00"}
