{"id":"https://openalex.org/W2289623484","doi":"https://doi.org/10.1109/tbcas.2015.2411732","title":"A Self-Calibrating Radar Sensor System for Measuring Vital Signs","display_name":"A Self-Calibrating Radar Sensor System for Measuring Vital Signs","publication_year":2015,"publication_date":"2015-05-19","ids":{"openalex":"https://openalex.org/W2289623484","doi":"https://doi.org/10.1109/tbcas.2015.2411732","mag":"2289623484","pmid":"https://pubmed.ncbi.nlm.nih.gov/26011865"},"language":"en","primary_location":{"id":"doi:10.1109/tbcas.2015.2411732","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbcas.2015.2411732","pdf_url":null,"source":{"id":"https://openalex.org/S80299757","display_name":"IEEE Transactions on Biomedical Circuits and Systems","issn_l":"1932-4545","issn":["1932-4545","1940-9990"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Circuits and Systems","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5020169895","display_name":"Ming-Chun Huang","orcid":"https://orcid.org/0000-0002-2269-4694"},"institutions":[{"id":"https://openalex.org/I58956616","display_name":"Case Western Reserve University","ror":"https://ror.org/051fd9666","country_code":"US","type":"education","lineage":["https://openalex.org/I58956616"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Ming-Chun Huang","raw_affiliation_strings":["Department of Electrical Engineering and Computer Science, Case Western Reserve University, OH, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering and Computer Science, Case Western Reserve University, OH, USA","institution_ids":["https://openalex.org/I58956616"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5002103276","display_name":"Jason J. Liu","orcid":"https://orcid.org/0000-0002-7379-5022"},"institutions":[{"id":"https://openalex.org/I161318765","display_name":"University of California, Los Angeles","ror":"https://ror.org/046rm7j60","country_code":"US","type":"education","lineage":["https://openalex.org/I161318765"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Jason J. Liu","raw_affiliation_strings":["Department of Computer Science, University of California, Los Angeles, CA, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Computer Science, University of California, Los Angeles, CA, USA","institution_ids":["https://openalex.org/I161318765"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5035679293","display_name":"Wenyao Xu","orcid":"https://orcid.org/0000-0001-6444-9411"},"institutions":[{"id":"https://openalex.org/I115441956","display_name":"Buffalo State University","ror":"https://ror.org/05ms04m92","country_code":"US","type":"education","lineage":["https://openalex.org/I115441956"]},{"id":"https://openalex.org/I63190737","display_name":"University at Buffalo, State University of New York","ror":"https://ror.org/01y64my43","country_code":"US","type":"education","lineage":["https://openalex.org/I63190737"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Wenyao Xu","raw_affiliation_strings":["Department of Computer Science and Engineering, SUNY, Buffalo, NY, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Computer Science and Engineering, SUNY, Buffalo, NY, USA","institution_ids":["https://openalex.org/I115441956","https://openalex.org/I63190737"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5066017923","display_name":"Changzhan Gu","orcid":"https://orcid.org/0000-0002-0224-9788"},"institutions":[{"id":"https://openalex.org/I33586118","display_name":"Lubbock Christian University","ror":"https://ror.org/02wb36b75","country_code":"US","type":"education","lineage":["https://openalex.org/I33586118"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Changzhan Gu","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Lubbock, TX, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Lubbock, TX, USA","institution_ids":["https://openalex.org/I33586118"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5025738581","display_name":"Changzhi Li","orcid":"https://orcid.org/0000-0003-2188-4506"},"institutions":[{"id":"https://openalex.org/I33586118","display_name":"Lubbock Christian University","ror":"https://ror.org/02wb36b75","country_code":"US","type":"education","lineage":["https://openalex.org/I33586118"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Changzhi Li","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Lubbock, TX, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Lubbock, TX, USA","institution_ids":["https://openalex.org/I33586118"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5078132977","display_name":"Majid Sarrafzadeh","orcid":"https://orcid.org/0000-0001-8407-8689"},"institutions":[{"id":"https://openalex.org/I161318765","display_name":"University of California, Los Angeles","ror":"https://ror.org/046rm7j60","country_code":"US","type":"education","lineage":["https://openalex.org/I161318765"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Majid Sarrafzadeh","raw_affiliation_strings":["Department of Computer Science, University of California, Los Angeles, CA, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Computer Science, University of California, Los Angeles, CA, USA","institution_ids":["https://openalex.org/I161318765"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":4.3177,"has_fulltext":false,"cited_by_count":87,"citation_normalized_percentile":{"value":0.94835817,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":90,"max":100},"biblio":{"volume":"10","issue":"2","first_page":"352","last_page":"363"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.9966999888420105,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T13248","display_name":"Healthcare Technology and Patient Monitoring","score":0.9933000206947327,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/vital-signs","display_name":"Vital signs","score":0.7405116558074951},{"id":"https://openalex.org/keywords/heartbeat","display_name":"Heartbeat","score":0.7200859785079956},{"id":"https://openalex.org/keywords/baseband","display_name":"Baseband","score":0.6827437877655029},{"id":"https://openalex.org/keywords/radar","display_name":"Radar","score":0.6407421231269836},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5786848664283752},{"id":"https://openalex.org/keywords/demodulation","display_name":"Demodulation","score":0.5720152854919434},{"id":"https://openalex.org/keywords/signal","display_name":"SIGNAL (programming language)","score":0.5293968915939331},{"id":"https://openalex.org/keywords/doppler-radar","display_name":"Doppler radar","score":0.5288919806480408},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.44449836015701294},{"id":"https://openalex.org/keywords/measure","display_name":"Measure (data warehouse)","score":0.41396409273147583},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.28123998641967773},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.11361527442932129}],"concepts":[{"id":"https://openalex.org/C2776890885","wikidata":"https://www.wikidata.org/wiki/Q1067560","display_name":"Vital signs","level":2,"score":0.7405116558074951},{"id":"https://openalex.org/C13852961","wikidata":"https://www.wikidata.org/wiki/Q17021880","display_name":"Heartbeat","level":2,"score":0.7200859785079956},{"id":"https://openalex.org/C65165936","wikidata":"https://www.wikidata.org/wiki/Q575784","display_name":"Baseband","level":3,"score":0.6827437877655029},{"id":"https://openalex.org/C554190296","wikidata":"https://www.wikidata.org/wiki/Q47528","display_name":"Radar","level":2,"score":0.6407421231269836},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5786848664283752},{"id":"https://openalex.org/C195251586","wikidata":"https://www.wikidata.org/wiki/Q1185939","display_name":"Demodulation","level":3,"score":0.5720152854919434},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.5293968915939331},{"id":"https://openalex.org/C2778559676","wikidata":"https://www.wikidata.org/wiki/Q1334213","display_name":"Doppler radar","level":3,"score":0.5288919806480408},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.44449836015701294},{"id":"https://openalex.org/C2780009758","wikidata":"https://www.wikidata.org/wiki/Q6804172","display_name":"Measure (data warehouse)","level":2,"score":0.41396409273147583},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.28123998641967773},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.11361527442932129},{"id":"https://openalex.org/C46362747","wikidata":"https://www.wikidata.org/wiki/Q173431","display_name":"CMOS","level":2,"score":0.0},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.0},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0},{"id":"https://openalex.org/C77088390","wikidata":"https://www.wikidata.org/wiki/Q8513","display_name":"Database","level":1,"score":0.0},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.0}],"mesh":[{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D002138","descriptor_name":"Calibration","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008872","descriptor_name":"Microwaves","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008872","descriptor_name":"Microwaves","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008872","descriptor_name":"Microwaves","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D012984","descriptor_name":"Software","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012984","descriptor_name":"Software","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012984","descriptor_name":"Software","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015374","descriptor_name":"Biosensing Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D015374","descriptor_name":"Biosensing Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D015374","descriptor_name":"Biosensing Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D015374","descriptor_name":"Biosensing Techniques","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D015374","descriptor_name":"Biosensing Techniques","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D015374","descriptor_name":"Biosensing Techniques","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D055986","descriptor_name":"Vital Signs","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D055986","descriptor_name":"Vital Signs","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D055986","descriptor_name":"Vital Signs","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/tbcas.2015.2411732","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbcas.2015.2411732","pdf_url":null,"source":{"id":"https://openalex.org/S80299757","display_name":"IEEE Transactions on Biomedical Circuits and Systems","issn_l":"1932-4545","issn":["1932-4545","1940-9990"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Circuits and Systems","raw_type":"journal-article"},{"id":"pmid:26011865","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/26011865","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on biomedical circuits and systems","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.41999998688697815,"id":"https://metadata.un.org/sdg/10","display_name":"Reduced inequalities"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":48,"referenced_works":["https://openalex.org/W1514891652","https://openalex.org/W1515683276","https://openalex.org/W1663973292","https://openalex.org/W1746819321","https://openalex.org/W1965209043","https://openalex.org/W1967689064","https://openalex.org/W1968624364","https://openalex.org/W1969205199","https://openalex.org/W1971662204","https://openalex.org/W2008227309","https://openalex.org/W2009086942","https://openalex.org/W2015295583","https://openalex.org/W2020172725","https://openalex.org/W2025609538","https://openalex.org/W2038323669","https://openalex.org/W2045727797","https://openalex.org/W2047763789","https://openalex.org/W2059246437","https://openalex.org/W2066663732","https://openalex.org/W2072916732","https://openalex.org/W2075861391","https://openalex.org/W2082848186","https://openalex.org/W2099743383","https://openalex.org/W2100210993","https://openalex.org/W2102948895","https://openalex.org/W2107868282","https://openalex.org/W2134363656","https://openalex.org/W2135301109","https://openalex.org/W2137449759","https://openalex.org/W2137619789","https://openalex.org/W2139496054","https://openalex.org/W2140427427","https://openalex.org/W2152125115","https://openalex.org/W2157743321","https://openalex.org/W2159522655","https://openalex.org/W2162632502","https://openalex.org/W2163222801","https://openalex.org/W2164452299","https://openalex.org/W2170172832","https://openalex.org/W2171942582","https://openalex.org/W2296616510","https://openalex.org/W2331016602","https://openalex.org/W2546505291","https://openalex.org/W4211049957","https://openalex.org/W4250589301","https://openalex.org/W4250955649","https://openalex.org/W6655815055","https://openalex.org/W6684723702"],"related_works":["https://openalex.org/W2011486145","https://openalex.org/W1009673011","https://openalex.org/W2026416740","https://openalex.org/W2083451322","https://openalex.org/W4246433483","https://openalex.org/W4230205216","https://openalex.org/W207143136","https://openalex.org/W2364871466","https://openalex.org/W2115249332","https://openalex.org/W4226059311"],"abstract_inverted_index":{"Vital":[0],"signs":[1,38,64],"(i.e.,":[2],"heartbeat":[3],"and":[4,27,51,74,97,103,122],"respiration)":[5],"are":[6,11],"crucial":[7],"physiological":[8],"signals":[9,22,67],"that":[10,126],"useful":[12],"in":[13,68],"numerous":[14],"medical":[15],"applications.":[16],"The":[17,48,109],"process":[18],"of":[19,111],"measuring":[20],"these":[21],"should":[23],"be":[24,130],"simple,":[25],"reliable,":[26],"comfortable":[28],"for":[29,77],"patients.":[30],"In":[31],"this":[32,127],"paper,":[33],"a":[34,56,75,83,91],"noncontact":[35],"self-calibrating":[36],"vital":[37,63,136],"monitoring":[39],"system":[40,49,114,128],"based":[41],"on":[42],"the":[43,69,100,112,123],"Doppler":[44],"radar":[45,70],"is":[46],"presented.":[47],"hardware":[50],"software":[52],"were":[53,72],"designed":[54],"with":[55],"four-tiered":[57],"layer":[58],"structure.":[59],"To":[60],"enable":[61],"accurate":[62],"measurement,":[65],"baseband":[66],"sensor":[71],"modeled":[73],"framework":[76],"signal":[78,84],"demodulation":[79],"was":[80,88,115],"proposed.":[81],"Specifically,":[82],"model":[85],"identification":[86],"method":[87],"formulated":[89],"into":[90],"quadratically":[92],"constrained":[93],"l1":[94],"minimization":[95],"problem":[96],"solved":[98],"using":[99,118],"upper":[101],"bound":[102],"linear":[104],"matrix":[105],"inequality":[106],"(LMI)":[107],"relaxations.":[108],"performance":[110],"proposed":[113],"comprehensively":[116],"evaluated":[117],"three":[119],"experimental":[120],"sets,":[121],"results":[124],"indicated":[125],"can":[129],"used":[131],"to":[132],"effectively":[133],"measure":[134],"human":[135],"signs.":[137]},"counts_by_year":[{"year":2026,"cited_by_count":3},{"year":2025,"cited_by_count":4},{"year":2024,"cited_by_count":4},{"year":2023,"cited_by_count":9},{"year":2022,"cited_by_count":6},{"year":2021,"cited_by_count":9},{"year":2020,"cited_by_count":10},{"year":2019,"cited_by_count":14},{"year":2018,"cited_by_count":15},{"year":2017,"cited_by_count":7},{"year":2016,"cited_by_count":5},{"year":2015,"cited_by_count":1}],"updated_date":"2026-07-25T15:57:00.446498","created_date":"2025-10-10T00:00:00"}
