{"id":"https://openalex.org/W2034894433","doi":"https://doi.org/10.1109/tbcas.2014.2326712","title":"Adaptive Pulse Width Control and Sampling for Low Power Pulse Oximetry","display_name":"Adaptive Pulse Width Control and Sampling for Low Power Pulse Oximetry","publication_year":2014,"publication_date":"2014-06-30","ids":{"openalex":"https://openalex.org/W2034894433","doi":"https://doi.org/10.1109/tbcas.2014.2326712","mag":"2034894433","pmid":"https://pubmed.ncbi.nlm.nih.gov/25014964"},"language":"en","primary_location":{"id":"doi:10.1109/tbcas.2014.2326712","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbcas.2014.2326712","pdf_url":null,"source":{"id":"https://openalex.org/S80299757","display_name":"IEEE Transactions on Biomedical Circuits and Systems","issn_l":"1932-4545","issn":["1932-4545","1940-9990"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Circuits and Systems","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5053181771","display_name":"Sagar Gubbi","orcid":null},"institutions":[{"id":"https://openalex.org/I59270414","display_name":"Indian Institute of Science Bangalore","ror":"https://ror.org/04dese585","country_code":"IN","type":"education","lineage":["https://openalex.org/I59270414"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Sagar Venkatesh Gubbi","raw_affiliation_strings":["Department of Electrical and Communication Engineering, Indian Institute of Science, Bangalore, India","Department of Electrical and Communication Engineering, Indian Institute of Science, Bangalore, India#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Communication Engineering, Indian Institute of Science, Bangalore, India","institution_ids":["https://openalex.org/I59270414"]},{"raw_affiliation_string":"Department of Electrical and Communication Engineering, Indian Institute of Science, Bangalore, India#TAB#","institution_ids":["https://openalex.org/I59270414"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5091221053","display_name":"Bharadwaj Amrutur","orcid":"https://orcid.org/0009-0007-5062-6174"},"institutions":[{"id":"https://openalex.org/I59270414","display_name":"Indian Institute of Science Bangalore","ror":"https://ror.org/04dese585","country_code":"IN","type":"education","lineage":["https://openalex.org/I59270414"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Bharadwaj Amrutur","raw_affiliation_strings":["Department of Electrical and Communication Engineering, Indian Institute of Science, Bangalore, India","Department of Electrical and Communication Engineering, Indian Institute of Science, Bangalore, India#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Communication Engineering, Indian Institute of Science, Bangalore, India","institution_ids":["https://openalex.org/I59270414"]},{"raw_affiliation_string":"Department of Electrical and Communication Engineering, Indian Institute of Science, Bangalore, India#TAB#","institution_ids":["https://openalex.org/I59270414"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.539,"has_fulltext":false,"cited_by_count":45,"citation_normalized_percentile":{"value":0.81981288,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":99},"biblio":{"volume":"9","issue":"2","first_page":"272","last_page":"283"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13248","display_name":"Healthcare Technology and Patient Monitoring","score":0.998199999332428,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9973000288009644,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/photoplethysmogram","display_name":"Photoplethysmogram","score":0.784896969795227},{"id":"https://openalex.org/keywords/pulse-oximetry","display_name":"Pulse oximetry","score":0.6888867616653442},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5769277215003967},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.5346288681030273},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.4988982677459717},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.4654548764228821},{"id":"https://openalex.org/keywords/interface","display_name":"Interface (matter)","score":0.4611220061779022},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.30616796016693115},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.2151191234588623},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.1160271167755127}],"concepts":[{"id":"https://openalex.org/C116390426","wikidata":"https://www.wikidata.org/wiki/Q7187885","display_name":"Photoplethysmogram","level":3,"score":0.784896969795227},{"id":"https://openalex.org/C2780124106","wikidata":"https://www.wikidata.org/wiki/Q1140495","display_name":"Pulse oximetry","level":2,"score":0.6888867616653442},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5769277215003967},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5346288681030273},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4988982677459717},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.4654548764228821},{"id":"https://openalex.org/C113843644","wikidata":"https://www.wikidata.org/wiki/Q901882","display_name":"Interface (matter)","level":4,"score":0.4611220061779022},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.30616796016693115},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.2151191234588623},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.1160271167755127},{"id":"https://openalex.org/C173608175","wikidata":"https://www.wikidata.org/wiki/Q232661","display_name":"Parallel computing","level":1,"score":0.0},{"id":"https://openalex.org/C157915830","wikidata":"https://www.wikidata.org/wiki/Q2928001","display_name":"Bubble","level":2,"score":0.0},{"id":"https://openalex.org/C42219234","wikidata":"https://www.wikidata.org/wiki/Q131130","display_name":"Anesthesia","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C129307140","wikidata":"https://www.wikidata.org/wiki/Q6795880","display_name":"Maximum bubble pressure method","level":3,"score":0.0}],"mesh":[{"descriptor_ui":"D000328","descriptor_name":"Adult","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000328","descriptor_name":"Adult","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000328","descriptor_name":"Adult","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006339","descriptor_name":"Heart Rate","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006339","descriptor_name":"Heart Rate","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006339","descriptor_name":"Heart Rate","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008954","descriptor_name":"Models, Biological","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008954","descriptor_name":"Models, Biological","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008954","descriptor_name":"Models, Biological","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D010092","descriptor_name":"Oximetry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017156","descriptor_name":"Photoplethysmography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017156","descriptor_name":"Photoplethysmography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017156","descriptor_name":"Photoplethysmography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D058998","descriptor_name":"Remote Sensing Technology","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D058998","descriptor_name":"Remote Sensing Technology","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D058998","descriptor_name":"Remote Sensing Technology","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D059629","descriptor_name":"Signal-To-Noise Ratio","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D059629","descriptor_name":"Signal-To-Noise Ratio","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D059629","descriptor_name":"Signal-To-Noise Ratio","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":3,"locations":[{"id":"doi:10.1109/tbcas.2014.2326712","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tbcas.2014.2326712","pdf_url":null,"source":{"id":"https://openalex.org/S80299757","display_name":"IEEE Transactions on Biomedical Circuits and Systems","issn_l":"1932-4545","issn":["1932-4545","1940-9990"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Biomedical Circuits and Systems","raw_type":"journal-article"},{"id":"pmid:25014964","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/25014964","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on biomedical circuits and systems","raw_type":null},{"id":"pmh:oai:eprints.iisc.ac.in:51655","is_oa":false,"landing_page_url":null,"pdf_url":null,"source":{"id":"https://openalex.org/S4377196309","display_name":"NOT FOUND REPOSITORY (Indian Institute of Science Bangalore)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I59270414","host_organization_name":"Indian Institute of Science Bangalore","host_organization_lineage":["https://openalex.org/I59270414"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"acceptedVersion","is_accepted":true,"is_published":false,"raw_source_name":"","raw_type":"Journal Article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8199999928474426,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320310071","display_name":"Indian Institute of Science","ror":"https://ror.org/04dese585"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":41,"referenced_works":["https://openalex.org/W101048444","https://openalex.org/W1500740677","https://openalex.org/W1566916904","https://openalex.org/W1620992469","https://openalex.org/W1855684705","https://openalex.org/W1926375926","https://openalex.org/W1983572876","https://openalex.org/W2018484897","https://openalex.org/W2040929996","https://openalex.org/W2056016955","https://openalex.org/W2067098972","https://openalex.org/W2089400127","https://openalex.org/W2090710454","https://openalex.org/W2098175786","https://openalex.org/W2099614038","https://openalex.org/W2104687293","https://openalex.org/W2107257373","https://openalex.org/W2108084237","https://openalex.org/W2109252375","https://openalex.org/W2109710637","https://openalex.org/W2112611349","https://openalex.org/W2115749363","https://openalex.org/W2122066044","https://openalex.org/W2128092100","https://openalex.org/W2131977672","https://openalex.org/W2146368254","https://openalex.org/W2147767292","https://openalex.org/W2154643950","https://openalex.org/W2155589764","https://openalex.org/W2157517987","https://openalex.org/W2159079926","https://openalex.org/W2162961804","https://openalex.org/W2397835102","https://openalex.org/W3150619482","https://openalex.org/W4212884325","https://openalex.org/W4232851490","https://openalex.org/W6639086132","https://openalex.org/W6646296827","https://openalex.org/W6675847749","https://openalex.org/W6679391765","https://openalex.org/W6712241448"],"related_works":["https://openalex.org/W4297152434","https://openalex.org/W2732360296","https://openalex.org/W1994871954","https://openalex.org/W2072858761","https://openalex.org/W4200107443","https://openalex.org/W4239033438","https://openalex.org/W1540261775","https://openalex.org/W1968279762","https://openalex.org/W4318970012","https://openalex.org/W2170552210"],"abstract_inverted_index":{"Remote":[0],"sensing":[1,22],"of":[2,70,128],"physiological":[3],"parameters":[4],"could":[5],"be":[6,114],"a":[7,33,44,57],"cost":[8],"effective":[9],"approach":[10,101],"to":[11,39,46,60,63,95,104,116],"improving":[12],"health":[13],"care,":[14],"and":[15,56,99],"low-power":[16,117],"sensors":[17,25],"are":[18,26],"essential":[19],"for":[20,51],"remote":[21],"because":[23],"these":[24],"often":[27],"energy":[28],"constrained.":[29],"This":[30],"paper":[31,112],"presents":[32],"power":[34,52,91,129],"optimized":[35],"photoplethysmographic":[36],"sensor":[37,54,118],"interface":[38,119],"sense":[40],"arterial":[41],"oxygen":[42],"saturation,":[43],"technique":[45],"dynamically":[47],"trade":[48],"off":[49],"SNR":[50],"during":[53],"operation,":[55],"simple":[58],"algorithm":[59],"choose":[61],"when":[62],"acquire":[64],"samples":[65,123],"in":[66,110,126],"photoplethysmography.":[67],"A":[68],"prototype":[69],"the":[71],"proposed":[72],"pulse":[73,133],"oximeter":[74],"built":[75],"using":[76],"commercial-off-the-shelf":[77],"(COTS)":[78],"components":[79],"is":[80,102,124],"tested":[81],"on":[82],"10":[83],"adults.":[84],"The":[85,107],"dynamic":[86],"adaptation":[87],"techniques":[88,108],"described":[89],"reduce":[90],"consumption":[92],"considerably":[93],"compared":[94],"our":[96,100],"reference":[97],"implementation,":[98],"competitive":[103],"state-of-the-art":[105],"implementations.":[106],"presented":[109],"this":[111],"may":[113],"applied":[115],"designs":[120],"where":[121],"acquiring":[122],"expensive":[125],"terms":[127],"as":[130],"epitomized":[131],"by":[132],"oximetry.":[134]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":8},{"year":2022,"cited_by_count":4},{"year":2021,"cited_by_count":5},{"year":2020,"cited_by_count":7},{"year":2019,"cited_by_count":4},{"year":2018,"cited_by_count":5},{"year":2017,"cited_by_count":4},{"year":2016,"cited_by_count":3},{"year":2015,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
