{"id":"https://openalex.org/W4416961848","doi":"https://doi.org/10.1109/systol66549.2025.11267382","title":"Fault Detection and Isolation Benchmark for Floating Offshore Wind Farms*","display_name":"Fault Detection and Isolation Benchmark for Floating Offshore Wind Farms*","publication_year":2025,"publication_date":"2025-10-06","ids":{"openalex":"https://openalex.org/W4416961848","doi":"https://doi.org/10.1109/systol66549.2025.11267382"},"language":"en","primary_location":{"id":"doi:10.1109/systol66549.2025.11267382","is_oa":false,"landing_page_url":"https://doi.org/10.1109/systol66549.2025.11267382","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 6th International Conference on Control and Fault-Tolerant Systems (SysTol)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://upcommons.upc.edu/bitstreams/21b08c9e-08e4-472d-aee9-1d3aad80bf76/download","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5047794164","display_name":"Yerai Pe\u00f1a\u2010Sanchez","orcid":"https://orcid.org/0000-0001-8614-0837"},"institutions":[{"id":"https://openalex.org/I162361429","display_name":"Mondragon Unibertsitatea","ror":"https://ror.org/00wvqgd19","country_code":"ES","type":"education","lineage":["https://openalex.org/I162361429"]}],"countries":["ES"],"is_corresponding":true,"raw_author_name":"Yerai Pe\u00f1a-Sanchez","raw_affiliation_strings":["Mondragon University, Mondragon University,Fluid Mechanics Department,Arrasate, Gipuzkoa,20500"],"affiliations":[{"raw_affiliation_string":"Mondragon University, Mondragon University,Fluid Mechanics Department,Arrasate, Gipuzkoa,20500","institution_ids":["https://openalex.org/I162361429"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5053209316","display_name":"Markel Pe\u00f1alba","orcid":"https://orcid.org/0000-0002-8396-7334"},"institutions":[{"id":"https://openalex.org/I162361429","display_name":"Mondragon Unibertsitatea","ror":"https://ror.org/00wvqgd19","country_code":"ES","type":"education","lineage":["https://openalex.org/I162361429"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Markel Penalba","raw_affiliation_strings":["Mondragon University, Mondragon University,Fluid Mechanics Department,Arrasate, Gipuzkoa,20500"],"affiliations":[{"raw_affiliation_string":"Mondragon University, Mondragon University,Fluid Mechanics Department,Arrasate, Gipuzkoa,20500","institution_ids":["https://openalex.org/I162361429"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5077592164","display_name":"Vincenzo Nava","orcid":"https://orcid.org/0000-0002-3207-3517"},"institutions":[{"id":"https://openalex.org/I177477856","display_name":"Polytechnic University of Turin","ror":"https://ror.org/00bgk9508","country_code":"IT","type":"education","lineage":["https://openalex.org/I177477856"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Vincenzo Nava","raw_affiliation_strings":["Politechnico di Torino,Department of Civil Engineering,Turin,Italy"],"affiliations":[{"raw_affiliation_string":"Politechnico di Torino,Department of Civil Engineering,Turin,Italy","institution_ids":["https://openalex.org/I177477856"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5023299508","display_name":"Vicen\u00e7 Puig","orcid":"https://orcid.org/0000-0002-6364-6429"},"institutions":[{"id":"https://openalex.org/I9617848","display_name":"Universitat Polit\u00e8cnica de Catalunya","ror":"https://ror.org/03mb6wj31","country_code":"ES","type":"education","lineage":["https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Vicen\u00e7 Puig","raw_affiliation_strings":["Polytechnic University of Catalonia,Department of Automatic Control,Barcelona, Barcelona,08034"],"affiliations":[{"raw_affiliation_string":"Polytechnic University of Catalonia,Department of Automatic Control,Barcelona, Barcelona,08034","institution_ids":["https://openalex.org/I9617848"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5047794164"],"corresponding_institution_ids":["https://openalex.org/I162361429"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":{"value":0.47112556,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"52","last_page":"58"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11250","display_name":"Wave and Wind Energy Systems","score":0.4311999976634979,"subfield":{"id":"https://openalex.org/subfields/2212","display_name":"Ocean Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11250","display_name":"Wave and Wind Energy Systems","score":0.4311999976634979,"subfield":{"id":"https://openalex.org/subfields/2212","display_name":"Ocean Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10680","display_name":"Wind Energy Research and Development","score":0.2313999980688095,"subfield":{"id":"https://openalex.org/subfields/2202","display_name":"Aerospace Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.07249999791383743,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/benchmark","display_name":"Benchmark (surveying)","score":0.8377000093460083},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.8101000189781189},{"id":"https://openalex.org/keywords/turbine","display_name":"Turbine","score":0.6317999958992004},{"id":"https://openalex.org/keywords/offshore-wind-power","display_name":"Offshore wind power","score":0.6086000204086304},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.5221999883651733},{"id":"https://openalex.org/keywords/wind-power","display_name":"Wind power","score":0.4936999976634979},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.49070000648498535},{"id":"https://openalex.org/keywords/modular-design","display_name":"Modular design","score":0.4810999929904938}],"concepts":[{"id":"https://openalex.org/C185798385","wikidata":"https://www.wikidata.org/wiki/Q1161707","display_name":"Benchmark (surveying)","level":2,"score":0.8377000093460083},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.8101000189781189},{"id":"https://openalex.org/C2778449969","wikidata":"https://www.wikidata.org/wiki/Q130760","display_name":"Turbine","level":2,"score":0.6317999958992004},{"id":"https://openalex.org/C8735168","wikidata":"https://www.wikidata.org/wiki/Q61637704","display_name":"Offshore wind power","level":3,"score":0.6086000204086304},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.5221999883651733},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.4936999976634979},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.49070000648498535},{"id":"https://openalex.org/C101468663","wikidata":"https://www.wikidata.org/wiki/Q1620158","display_name":"Modular design","level":2,"score":0.4810999929904938},{"id":"https://openalex.org/C199104240","wikidata":"https://www.wikidata.org/wiki/Q118291","display_name":"Marine engineering","level":1,"score":0.46050000190734863},{"id":"https://openalex.org/C2775941552","wikidata":"https://www.wikidata.org/wiki/Q25212305","display_name":"Isolation (microbiology)","level":2,"score":0.45829999446868896},{"id":"https://openalex.org/C162284963","wikidata":"https://www.wikidata.org/wiki/Q17106102","display_name":"Submarine pipeline","level":2,"score":0.43540000915527344},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4293000102043152},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4228000044822693},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.40119999647140503},{"id":"https://openalex.org/C77052588","wikidata":"https://www.wikidata.org/wiki/Q644307","display_name":"Constant false alarm rate","level":2,"score":0.3675999939441681},{"id":"https://openalex.org/C2779119184","wikidata":"https://www.wikidata.org/wiki/Q294350","display_name":"ALARM","level":2,"score":0.3571000099182129},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3411000072956085},{"id":"https://openalex.org/C182365436","wikidata":"https://www.wikidata.org/wiki/Q50701","display_name":"Variable (mathematics)","level":2,"score":0.33820000290870667},{"id":"https://openalex.org/C2776836416","wikidata":"https://www.wikidata.org/wiki/Q1364844","display_name":"False alarm","level":2,"score":0.29919999837875366},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.27090001106262207},{"id":"https://openalex.org/C18762648","wikidata":"https://www.wikidata.org/wiki/Q42213","display_name":"Work (physics)","level":2,"score":0.26330000162124634},{"id":"https://openalex.org/C34329639","wikidata":"https://www.wikidata.org/wiki/Q27070220","display_name":"Nacelle","level":3,"score":0.25270000100135803},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.25130000710487366}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/systol66549.2025.11267382","is_oa":false,"landing_page_url":"https://doi.org/10.1109/systol66549.2025.11267382","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 6th International Conference on Control and Fault-Tolerant Systems (SysTol)","raw_type":"proceedings-article"},{"id":"pmh:oai:upcommons.upc.edu:2117/459376","is_oa":true,"landing_page_url":"https://hdl.handle.net/2117/459376","pdf_url":"https://upcommons.upc.edu/bitstreams/21b08c9e-08e4-472d-aee9-1d3aad80bf76/download","source":{"id":"https://openalex.org/S4377196262","display_name":"UPCommons institutional repository (Universitat Polit\u00e8cnica de Catalunya)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I9617848","host_organization_name":"Universitat Polit\u00e8cnica de Catalunya","host_organization_lineage":["https://openalex.org/I9617848"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":{"id":"pmh:oai:upcommons.upc.edu:2117/459376","is_oa":true,"landing_page_url":"https://hdl.handle.net/2117/459376","pdf_url":"https://upcommons.upc.edu/bitstreams/21b08c9e-08e4-472d-aee9-1d3aad80bf76/download","source":{"id":"https://openalex.org/S4377196262","display_name":"UPCommons institutional repository (Universitat Polit\u00e8cnica de Catalunya)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I9617848","host_organization_name":"Universitat Polit\u00e8cnica de Catalunya","host_organization_lineage":["https://openalex.org/I9617848"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/conferenceObject"},"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4416961848.pdf","grobid_xml":"https://content.openalex.org/works/W4416961848.grobid-xml"},"referenced_works_count":13,"referenced_works":["https://openalex.org/W1533975523","https://openalex.org/W1988499271","https://openalex.org/W2014632329","https://openalex.org/W2042641006","https://openalex.org/W2113609567","https://openalex.org/W2285228247","https://openalex.org/W2626314531","https://openalex.org/W2765406622","https://openalex.org/W2903668766","https://openalex.org/W4212861833","https://openalex.org/W4280588149","https://openalex.org/W4399839141","https://openalex.org/W4405160142"],"related_works":[],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"a":[3,35,112],"benchmark":[4,33,83,137],"for":[5,23,150],"fault":[6,70,145],"detection":[7,103,146],"and":[8,53,68,74,80,93,106,116,147],"isolation":[9,108],"(FDI)":[10],"in":[11,144],"floating":[12,40,133],"offshore":[13,134,151],"wind":[14,36,60,152],"farms,":[15],"addressing":[16],"the":[17,29,32,44,129],"lack":[18],"of":[19,124,132],"standardized":[20],"evaluation":[21,94],"frameworks":[22],"this":[24,119],"emerging":[25],"technology.":[26],"Developed":[27],"using":[28],"FOWLTY":[30],"simulator,":[31],"models":[34],"farm":[37],"with":[38,77,87],"seven":[39],"turbines":[41],"based":[42],"on":[43],"NREL":[45],"<tex":[46],"xmlns:mml=\"http://www.w3.org/1998/Math/MathML\"":[47,63],"xmlns:xlink=\"http://www.w3.org/1999/xlink\">$\\mathbf{5":[48],"M":[49],"W}$</tex>":[50],"reference":[51,91],"turbine":[52],"DeepCWind":[54],"platform.":[55],"It":[56],"incorporates":[57],"ten":[58],"diverse":[59],"scenarios":[61],"(<tex":[62],"xmlns:xlink=\"http://www.w3.org/1999/xlink\">$5-23":[64],"~\\mathrm{m}":[65],"/":[66],"\\mathrm{s}$</tex>)":[67],"realistic":[69],"conditions,":[71],"including":[72],"sensor":[73,85],"actuator":[75,90],"faults":[76],"variable":[78],"severity":[79],"timing.":[81],"The":[82,136],"provides":[84],"measurements":[86],"injected":[88],"noise,":[89],"signals,":[92],"metrics":[95],"such":[96],"as":[97],"false":[98],"alarm":[99],"rate":[100,104],"(FAR),":[101],"missed":[102],"(MDR),":[105],"correct":[107],"rate.":[109],"By":[110],"offering":[111],"modular":[113],"Simulink":[114],"environment":[115],"customizable":[117],"datasets,":[118],"work":[120],"enables":[121],"reproducible":[122],"comparisons":[123],"FDI":[125],"methods":[126],"while":[127],"highlighting":[128],"unique":[130],"dynamics":[131],"systems.":[135],"is":[138],"publicly":[139],"available":[140],"to":[141],"support":[142],"research":[143],"fault-tolerant":[148],"control":[149],"energy.":[153]},"counts_by_year":[],"updated_date":"2026-03-31T07:56:22.981413","created_date":"2025-12-03T00:00:00"}
