{"id":"https://openalex.org/W2806060664","doi":"https://doi.org/10.1109/syscon.2018.8369537","title":"Remote and dynamic assessment of reliability in electromechanical actuator systems","display_name":"Remote and dynamic assessment of reliability in electromechanical actuator systems","publication_year":2018,"publication_date":"2018-04-01","ids":{"openalex":"https://openalex.org/W2806060664","doi":"https://doi.org/10.1109/syscon.2018.8369537","mag":"2806060664"},"language":"en","primary_location":{"id":"doi:10.1109/syscon.2018.8369537","is_oa":false,"landing_page_url":"https://doi.org/10.1109/syscon.2018.8369537","pdf_url":null,"source":{"id":"https://openalex.org/S4306498283","display_name":"2018 Annual IEEE International Systems Conference (SysCon)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 Annual IEEE International Systems Conference (SysCon)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5006148096","display_name":"Miles Brim","orcid":null},"institutions":[{"id":"https://openalex.org/I92446798","display_name":"Colorado State University","ror":"https://ror.org/03k1gpj17","country_code":"US","type":"education","lineage":["https://openalex.org/I92446798"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Miles Brim","raw_affiliation_strings":["Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, USA"],"affiliations":[{"raw_affiliation_string":"Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, USA","institution_ids":["https://openalex.org/I92446798"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5102745494","display_name":"James Cale","orcid":"https://orcid.org/0000-0002-3233-3956"},"institutions":[{"id":"https://openalex.org/I92446798","display_name":"Colorado State University","ror":"https://ror.org/03k1gpj17","country_code":"US","type":"education","lineage":["https://openalex.org/I92446798"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"James Cale","raw_affiliation_strings":["Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, USA"],"affiliations":[{"raw_affiliation_string":"Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, USA","institution_ids":["https://openalex.org/I92446798"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5006148096"],"corresponding_institution_ids":["https://openalex.org/I92446798"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.05764967,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"11","issue":null,"first_page":"1","last_page":"8"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9983999729156494,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9983999729156494,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11890","display_name":"Scientific Measurement and Uncertainty Evaluation","score":0.9929999709129333,"subfield":{"id":"https://openalex.org/subfields/1804","display_name":"Statistics, Probability and Uncertainty"},"field":{"id":"https://openalex.org/fields/18","display_name":"Decision Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}},{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.9908999800682068,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.8761643171310425},{"id":"https://openalex.org/keywords/monte-carlo-method","display_name":"Monte Carlo method","score":0.7087904214859009},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.7050234079360962},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.61724454164505},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5923992395401001},{"id":"https://openalex.org/keywords/scheduling","display_name":"Scheduling (production processes)","score":0.4734111428260803},{"id":"https://openalex.org/keywords/reliability-theory","display_name":"Reliability theory","score":0.4501044452190399},{"id":"https://openalex.org/keywords/maintenance-engineering","display_name":"Maintenance engineering","score":0.4416542053222656},{"id":"https://openalex.org/keywords/control-system","display_name":"Control system","score":0.4318045973777771},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.35904520750045776},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.35240375995635986},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.3294749855995178},{"id":"https://openalex.org/keywords/failure-rate","display_name":"Failure rate","score":0.3004366159439087},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.19529008865356445}],"concepts":[{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.8761643171310425},{"id":"https://openalex.org/C19499675","wikidata":"https://www.wikidata.org/wiki/Q232207","display_name":"Monte Carlo method","level":2,"score":0.7087904214859009},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.7050234079360962},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.61724454164505},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5923992395401001},{"id":"https://openalex.org/C206729178","wikidata":"https://www.wikidata.org/wiki/Q2271896","display_name":"Scheduling (production processes)","level":2,"score":0.4734111428260803},{"id":"https://openalex.org/C201729545","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability theory","level":3,"score":0.4501044452190399},{"id":"https://openalex.org/C23725684","wikidata":"https://www.wikidata.org/wiki/Q616377","display_name":"Maintenance engineering","level":2,"score":0.4416542053222656},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.4318045973777771},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.35904520750045776},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.35240375995635986},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3294749855995178},{"id":"https://openalex.org/C163164238","wikidata":"https://www.wikidata.org/wiki/Q2737027","display_name":"Failure rate","level":2,"score":0.3004366159439087},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.19529008865356445},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/syscon.2018.8369537","is_oa":false,"landing_page_url":"https://doi.org/10.1109/syscon.2018.8369537","pdf_url":null,"source":{"id":"https://openalex.org/S4306498283","display_name":"2018 Annual IEEE International Systems Conference (SysCon)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 Annual IEEE International Systems Conference (SysCon)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":18,"referenced_works":["https://openalex.org/W160318044","https://openalex.org/W1496395723","https://openalex.org/W1511368807","https://openalex.org/W2014938333","https://openalex.org/W2087904477","https://openalex.org/W2108366027","https://openalex.org/W2315321978","https://openalex.org/W2492309557","https://openalex.org/W2497275036","https://openalex.org/W2578872054","https://openalex.org/W2606415487","https://openalex.org/W2614894764","https://openalex.org/W2722925682","https://openalex.org/W2773353775","https://openalex.org/W4205358276","https://openalex.org/W6672756060","https://openalex.org/W6685668925","https://openalex.org/W6740528012"],"related_works":["https://openalex.org/W2042729523","https://openalex.org/W2138734817","https://openalex.org/W2146720862","https://openalex.org/W2096858855","https://openalex.org/W2060246408","https://openalex.org/W2911869115","https://openalex.org/W2024959703","https://openalex.org/W4361251166","https://openalex.org/W2076048247","https://openalex.org/W1979470315"],"abstract_inverted_index":{"This":[0],"paper":[1,53],"describes":[2],"a":[3,28,55,68],"method":[4,56],"for":[5,27,35,57],"assessing":[6],"dynamic":[7],"reliability":[8,43],"of":[9,22,30],"electromechanical":[10,70],"actuator":[11,74],"systems":[12],"using":[13,46,62],"limited":[14],"external":[15],"sensor":[16],"measurements,":[17],"with":[18,67],"the":[19,40,73,80],"overall":[20],"goal":[21],"providing":[23],"optimized":[24],"maintenance":[25],"scheduling":[26],"fleet":[29],"deployed":[31],"systems.":[32],"To":[33],"account":[34],"special":[36,49],"cause":[37],"failures":[38],"in":[39],"actuators,":[41],"nominal":[42],"is":[44],"adjusted":[45],"an":[47],"accumulated":[48],"hazard":[50],"function.":[51],"The":[52],"illustrates":[54],"obtaining":[58],"statistical":[59],"control":[60],"thresholds":[61],"Monte":[63],"Carlo":[64],"analysis":[65],"coupled":[66],"detailed":[69],"model":[71],"describing":[72],"system.":[75],"Numerical":[76],"simulation":[77],"studies":[78],"demonstrate":[79],"approach.":[81]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
