{"id":"https://openalex.org/W2617524202","doi":"https://doi.org/10.1109/syscon.2017.7934792","title":"Energy management system for automated driving: Optimal and adaptive control strategy for normal and failure case operation","display_name":"Energy management system for automated driving: Optimal and adaptive control strategy for normal and failure case operation","publication_year":2017,"publication_date":"2017-04-01","ids":{"openalex":"https://openalex.org/W2617524202","doi":"https://doi.org/10.1109/syscon.2017.7934792","mag":"2617524202"},"language":"en","primary_location":{"id":"doi:10.1109/syscon.2017.7934792","is_oa":false,"landing_page_url":"https://doi.org/10.1109/syscon.2017.7934792","pdf_url":null,"source":{"id":"https://openalex.org/S4306498133","display_name":"2017 Annual IEEE International Systems Conference (SysCon)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 Annual IEEE International Systems Conference (SysCon)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5086133983","display_name":"Kirill Gorelik","orcid":"https://orcid.org/0000-0001-6813-6076"},"institutions":[{"id":"https://openalex.org/I889804353","display_name":"Robert Bosch (Germany)","ror":"https://ror.org/01fe0jt45","country_code":"DE","type":"company","lineage":["https://openalex.org/I889804353"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Kirill Gorelik","raw_affiliation_strings":["Corporate Sector Research and Advance Engineering Robert Bosch GmbH, Renningen, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Corporate Sector Research and Advance Engineering Robert Bosch GmbH, Renningen, Germany","institution_ids":["https://openalex.org/I889804353"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5064774898","display_name":"Ahmet K\u0131l\u0131\u00e7","orcid":"https://orcid.org/0000-0002-8990-4457"},"institutions":[{"id":"https://openalex.org/I889804353","display_name":"Robert Bosch (Germany)","ror":"https://ror.org/01fe0jt45","country_code":"DE","type":"company","lineage":["https://openalex.org/I889804353"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Ahmet Kilic","raw_affiliation_strings":["Corporate Sector Research and Advance Engineering Robert Bosch GmbH, Renningen, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Corporate Sector Research and Advance Engineering Robert Bosch GmbH, Renningen, Germany","institution_ids":["https://openalex.org/I889804353"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5007015294","display_name":"Roman Obermaisser","orcid":"https://orcid.org/0009-0002-4483-1503"},"institutions":[{"id":"https://openalex.org/I206895457","display_name":"University of Siegen","ror":"https://ror.org/02azyry73","country_code":"DE","type":"education","lineage":["https://openalex.org/I206895457"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Roman Obermaisser","raw_affiliation_strings":["Institute of Embedded Systems, University of Siegen, Siegen, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Embedded Systems, University of Siegen, Siegen, Germany","institution_ids":["https://openalex.org/I206895457"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":12,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"8"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10808","display_name":"Electric and Hybrid Vehicle Technologies","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10808","display_name":"Electric and Hybrid Vehicle Technologies","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10768","display_name":"Electric Vehicles and Infrastructure","score":0.9954000115394592,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12095","display_name":"Vehicle emissions and performance","score":0.9916999936103821,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.6258320808410645},{"id":"https://openalex.org/keywords/energy-management","display_name":"Energy management","score":0.6100987195968628},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5904524326324463},{"id":"https://openalex.org/keywords/automation","display_name":"Automation","score":0.579727828502655},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.5752809047698975},{"id":"https://openalex.org/keywords/power-management","display_name":"Power management","score":0.5376518964767456},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.4628201425075531},{"id":"https://openalex.org/keywords/energy-management-system","display_name":"Energy management system","score":0.44344931840896606},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.4361857771873474},{"id":"https://openalex.org/keywords/energy-supply","display_name":"Energy supply","score":0.4295191168785095},{"id":"https://openalex.org/keywords/work","display_name":"Work (physics)","score":0.4259319007396698},{"id":"https://openalex.org/keywords/power-control","display_name":"Power control","score":0.42055264115333557},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.38360658288002014},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3077443242073059}],"concepts":[{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.6258320808410645},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.6100987195968628},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5904524326324463},{"id":"https://openalex.org/C115901376","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automation","level":2,"score":0.579727828502655},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5752809047698975},{"id":"https://openalex.org/C2778774385","wikidata":"https://www.wikidata.org/wiki/Q4437810","display_name":"Power management","level":3,"score":0.5376518964767456},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.4628201425075531},{"id":"https://openalex.org/C2781260460","wikidata":"https://www.wikidata.org/wiki/Q6139999","display_name":"Energy management system","level":4,"score":0.44344931840896606},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.4361857771873474},{"id":"https://openalex.org/C2776190866","wikidata":"https://www.wikidata.org/wiki/Q1341477","display_name":"Energy supply","level":3,"score":0.4295191168785095},{"id":"https://openalex.org/C18762648","wikidata":"https://www.wikidata.org/wiki/Q42213","display_name":"Work (physics)","level":2,"score":0.4259319007396698},{"id":"https://openalex.org/C56685638","wikidata":"https://www.wikidata.org/wiki/Q2300474","display_name":"Power control","level":3,"score":0.42055264115333557},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.38360658288002014},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3077443242073059},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/syscon.2017.7934792","is_oa":false,"landing_page_url":"https://doi.org/10.1109/syscon.2017.7934792","pdf_url":null,"source":{"id":"https://openalex.org/S4306498133","display_name":"2017 Annual IEEE International Systems Conference (SysCon)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 Annual IEEE International Systems Conference (SysCon)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.8999999761581421}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":3,"referenced_works":["https://openalex.org/W28875312","https://openalex.org/W2535412924","https://openalex.org/W4246640070"],"related_works":["https://openalex.org/W2749199243","https://openalex.org/W2333017163","https://openalex.org/W2133545517","https://openalex.org/W2352231626","https://openalex.org/W2964681094","https://openalex.org/W2782741053","https://openalex.org/W2577786578","https://openalex.org/W2896932934","https://openalex.org/W1984852161","https://openalex.org/W4315574134"],"abstract_inverted_index":{"With":[0],"increasing":[1],"level":[2],"of":[3,36,121],"driving":[4,64,115,122],"automation":[5],"new":[6,20],"requirements":[7],"regarding":[8],"reliable":[9,139],"power":[10,13,22,29,60,93,140,143],"supply":[11,30,141],"for":[12,33,53,62,142],"net":[14,94,144],"components":[15,145],"arise.":[16],"In":[17],"addition":[18],"to":[19,39,101,105,129],"fail-operational":[21,59],"nets,":[23],"appropriate":[24],"control":[25,127],"strategies":[26],"providing":[27],"functional":[28],"at":[31,108],"least":[32],"the":[34,82,91,103,109,113,119,126,130,134,148],"duration":[35],"vehicle":[37,104],"transition":[38],"a":[40,49,79,98,106],"safe":[41],"state":[42],"(standstill)":[43],"are":[44],"required.":[45],"This":[46],"paper":[47],"presents":[48],"generic,":[50],"topology-independent":[51],"concept":[52],"future":[54],"energy":[55,75,83,95,135,150],"management":[56,84,136],"systems":[57],"controlling":[58],"nets":[61],"automated":[63],"in":[65,87,97],"both":[66],"normal":[67],"and":[68,78,117,146],"failure":[69],"cases.":[70],"Based":[71],"on":[72],"predictive":[73],"runtime":[74],"flow":[76],"optimization":[77],"3-level-degradation":[80],"concept,":[81],"system":[85,132,137],"presented":[86],"this":[88],"work":[89],"allocates":[90],"available":[92],"resources":[96],"way":[99],"allowing":[100],"bring":[102],"standstill":[107],"safest":[110],"location":[111],"with":[112,118],"best-suited":[114],"profile":[116],"maximum":[120],"comfort.":[123],"By":[124],"adapting":[125],"strategy":[128],"current":[131],"state,":[133],"enables":[138],"increases":[147],"overall":[149],"efficiency.":[151]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":5},{"year":2018,"cited_by_count":3},{"year":2017,"cited_by_count":2}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
