{"id":"https://openalex.org/W2904459703","doi":"https://doi.org/10.1109/ssd.2018.8570481","title":"Fault Diagnosis and Fault Tolerant Control Against Simultaneous Sensor and Actuator Faults for Linear Stochastic Systems","display_name":"Fault Diagnosis and Fault Tolerant Control Against Simultaneous Sensor and Actuator Faults for Linear Stochastic Systems","publication_year":2018,"publication_date":"2018-03-01","ids":{"openalex":"https://openalex.org/W2904459703","doi":"https://doi.org/10.1109/ssd.2018.8570481","mag":"2904459703"},"language":"en","primary_location":{"id":"doi:10.1109/ssd.2018.8570481","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ssd.2018.8570481","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 15th International Multi-Conference on Systems, Signals &amp; Devices (SSD)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5076525781","display_name":"Marwa Houiji","orcid":null},"institutions":[{"id":"https://openalex.org/I68916915","display_name":"University of Gab\u00e8s","ror":"https://ror.org/022efad20","country_code":"TN","type":"education","lineage":["https://openalex.org/I68916915"]}],"countries":["TN"],"is_corresponding":true,"raw_author_name":"Marwa Houiji","raw_affiliation_strings":["Gab\u00e8s university, MACS, Tunisia"],"affiliations":[{"raw_affiliation_string":"Gab\u00e8s university, MACS, Tunisia","institution_ids":["https://openalex.org/I68916915"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5107931368","display_name":"Rim Hamdaoui","orcid":"https://orcid.org/0000-0002-7909-1659"},"institutions":[{"id":"https://openalex.org/I68916915","display_name":"University of Gab\u00e8s","ror":"https://ror.org/022efad20","country_code":"TN","type":"education","lineage":["https://openalex.org/I68916915"]}],"countries":["TN"],"is_corresponding":false,"raw_author_name":"Rim Hamdaoui","raw_affiliation_strings":["Gab\u00e8s university, National Engineering School of Gab\u00e8s, MACS, 6029, Tunisia"],"affiliations":[{"raw_affiliation_string":"Gab\u00e8s university, National Engineering School of Gab\u00e8s, MACS, 6029, Tunisia","institution_ids":["https://openalex.org/I68916915"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5060280147","display_name":"Mohamed Aoun","orcid":"https://orcid.org/0000-0003-1956-5119"},"institutions":[{"id":"https://openalex.org/I68916915","display_name":"University of Gab\u00e8s","ror":"https://ror.org/022efad20","country_code":"TN","type":"education","lineage":["https://openalex.org/I68916915"]}],"countries":["TN"],"is_corresponding":false,"raw_author_name":"Mohamed Aoun","raw_affiliation_strings":["Gab\u00e8s university, MACS, Tunisia"],"affiliations":[{"raw_affiliation_string":"Gab\u00e8s university, MACS, Tunisia","institution_ids":["https://openalex.org/I68916915"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5076525781"],"corresponding_institution_ids":["https://openalex.org/I68916915"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.16914365,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"810","last_page":"815"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.9850999712944031,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11236","display_name":"Control Systems and Identification","score":0.9822999835014343,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/residual","display_name":"Residual","score":0.764060378074646},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.7153985500335693},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.6968819499015808},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.6617843508720398},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6113840341567993},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.6057085990905762},{"id":"https://openalex.org/keywords/kalman-filter","display_name":"Kalman filter","score":0.5806920528411865},{"id":"https://openalex.org/keywords/false-alarm","display_name":"False alarm","score":0.5334045886993408},{"id":"https://openalex.org/keywords/linear-system","display_name":"Linear system","score":0.4310522675514221},{"id":"https://openalex.org/keywords/constant-false-alarm-rate","display_name":"Constant false alarm rate","score":0.41676998138427734},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.25926023721694946},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.23036912083625793},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.18069708347320557},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.18069621920585632}],"concepts":[{"id":"https://openalex.org/C155512373","wikidata":"https://www.wikidata.org/wiki/Q287450","display_name":"Residual","level":2,"score":0.764060378074646},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.7153985500335693},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6968819499015808},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.6617843508720398},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6113840341567993},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6057085990905762},{"id":"https://openalex.org/C157286648","wikidata":"https://www.wikidata.org/wiki/Q846780","display_name":"Kalman filter","level":2,"score":0.5806920528411865},{"id":"https://openalex.org/C2776836416","wikidata":"https://www.wikidata.org/wiki/Q1364844","display_name":"False alarm","level":2,"score":0.5334045886993408},{"id":"https://openalex.org/C6802819","wikidata":"https://www.wikidata.org/wiki/Q1072174","display_name":"Linear system","level":2,"score":0.4310522675514221},{"id":"https://openalex.org/C77052588","wikidata":"https://www.wikidata.org/wiki/Q644307","display_name":"Constant false alarm rate","level":2,"score":0.41676998138427734},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.25926023721694946},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.23036912083625793},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.18069708347320557},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.18069621920585632},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ssd.2018.8570481","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ssd.2018.8570481","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 15th International Multi-Conference on Systems, Signals &amp; Devices (SSD)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W1597576211","https://openalex.org/W1811189874","https://openalex.org/W1975491903","https://openalex.org/W2003676131","https://openalex.org/W2120347155","https://openalex.org/W2137209890","https://openalex.org/W2139494503","https://openalex.org/W2140786825","https://openalex.org/W2170151830","https://openalex.org/W2400182419","https://openalex.org/W2586844786","https://openalex.org/W2766846123"],"related_works":["https://openalex.org/W2118844790","https://openalex.org/W1983393909","https://openalex.org/W2040150569","https://openalex.org/W2774527540","https://openalex.org/W2468095590","https://openalex.org/W2132174924","https://openalex.org/W2096333878","https://openalex.org/W1911540634","https://openalex.org/W2013909972","https://openalex.org/W2762711590"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"the":[3,43,47,66,73,77,84,98,117,121],"problem":[4],"of":[5,14,58],"robust":[6,100],"fault":[7,44,101],"diagnosis":[8],"and":[9,21,46,76,129],"accommodation":[10],"for":[11,114],"a":[12,27],"class":[13],"linear":[15],"stochastic":[16],"systems":[17],"where":[18],"simultaneous":[19],"actuator":[20],"sensor":[22],"faults":[23,94],"may":[24],"occur":[25],"at":[26],"given":[28],"time.":[29],"Firstly,":[30],"based":[31,64],"on":[32,65,120],"Augmented":[33],"Robust":[34],"Three":[35],"stage":[36],"Kalman":[37],"filters":[38],"(ARThSKF)":[39],"we":[40,130],"obtained":[41],"both":[42],"estimation":[45],"residual":[48,51],"signal.":[49],"Then,":[50],"evaluation":[52],"is":[53,112],"achieved":[54],"by":[55,83],"making":[56],"use":[57],"an":[59,108],"adaptive":[60],"threshold":[61],"adjustment":[62],"algorithm":[63],"grey":[67],"theory.":[68],"Obtained":[69],"results":[70],"show":[71],"that":[72],"false-alarm":[74],"rates":[75,80],"missing":[78],"alarm":[79],"are":[81],"minimized":[82],"developed":[85],"method;":[86],"also":[87],"this":[88],"approach":[89],"detects":[90],"small":[91],"or":[92],"incipient":[93],"more":[95],"effectively":[96],"than":[97],"classical":[99],"detection":[102],"algorithms":[103],"with":[104],"fixed":[105],"thresholds.":[106],"Finally,":[107],"additive":[109],"control":[110],"input":[111],"introduced":[113],"cancelling":[115],"out":[116],"fault's":[118],"effect":[119],"system.":[122],"We":[123],"evaluate":[124],"our":[125],"proposal":[126],"through":[127],"simulation":[128],"demonstrate":[131],"its":[132],"feasibility.":[133]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2022,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}