{"id":"https://openalex.org/W2087513044","doi":"https://doi.org/10.1109/softcom.2014.7039090","title":"Energy-efficient clock synchronization using wake-up receivers","display_name":"Energy-efficient clock synchronization using wake-up receivers","publication_year":2014,"publication_date":"2014-09-01","ids":{"openalex":"https://openalex.org/W2087513044","doi":"https://doi.org/10.1109/softcom.2014.7039090","mag":"2087513044"},"language":"en","primary_location":{"id":"doi:10.1109/softcom.2014.7039090","is_oa":false,"landing_page_url":"https://doi.org/10.1109/softcom.2014.7039090","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 22nd International Conference on Software, Telecommunications and Computer Networks (SoftCOM)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5003179904","display_name":"Johannes Blanckenstein","orcid":null},"institutions":[{"id":"https://openalex.org/I112991645","display_name":"Airbus (France)","ror":"https://ror.org/023qdcg29","country_code":"FR","type":"company","lineage":["https://openalex.org/I112991645","https://openalex.org/I4210121748"]}],"countries":["FR"],"is_corresponding":true,"raw_author_name":"Johannes Blanckenstein","raw_affiliation_strings":["Airbus Group Innovations, Dept. TX4CW","Airbus Group Innovations, Dept. TX4CW, Germany"],"affiliations":[{"raw_affiliation_string":"Airbus Group Innovations, Dept. TX4CW","institution_ids":["https://openalex.org/I112991645"]},{"raw_affiliation_string":"Airbus Group Innovations, Dept. TX4CW, Germany","institution_ids":["https://openalex.org/I112991645"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5019777818","display_name":"Holger Karl","orcid":"https://orcid.org/0000-0002-8343-6322"},"institutions":[{"id":"https://openalex.org/I206945453","display_name":"Paderborn University","ror":"https://ror.org/058kzsd48","country_code":"DE","type":"education","lineage":["https://openalex.org/I206945453"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Holger Karl","raw_affiliation_strings":["Research Group Computer Networks, University Paderborn","University Paderborn, Research Group Computer Networks, Germany"],"affiliations":[{"raw_affiliation_string":"Research Group Computer Networks, University Paderborn","institution_ids":["https://openalex.org/I206945453"]},{"raw_affiliation_string":"University Paderborn, Research Group Computer Networks, Germany","institution_ids":["https://openalex.org/I206945453"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5003179904"],"corresponding_institution_ids":["https://openalex.org/I112991645"],"apc_list":null,"apc_paid":null,"fwci":0.3619,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.685299,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"408","last_page":"413"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12216","display_name":"Network Time Synchronization Technologies","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12216","display_name":"Network Time Synchronization Technologies","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10080","display_name":"Energy Efficient Wireless Sensor Networks","score":0.9879000186920166,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11417","display_name":"Advancements in PLL and VCO Technologies","score":0.977400004863739,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/synchronization","display_name":"Synchronization (alternating current)","score":0.8146982192993164},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7013913989067078},{"id":"https://openalex.org/keywords/wireless-sensor-network","display_name":"Wireless sensor network","score":0.5916810631752014},{"id":"https://openalex.org/keywords/clock-synchronization","display_name":"Clock synchronization","score":0.5847969055175781},{"id":"https://openalex.org/keywords/clock-drift","display_name":"Clock drift","score":0.5552828311920166},{"id":"https://openalex.org/keywords/transceiver","display_name":"Transceiver","score":0.55442875623703},{"id":"https://openalex.org/keywords/wake","display_name":"Wake","score":0.5293501019477844},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.5289497375488281},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.473423033952713},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.4536331593990326},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.4447006583213806},{"id":"https://openalex.org/keywords/duty-cycle","display_name":"Duty cycle","score":0.4407261908054352},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.3981893062591553},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.33724915981292725},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.21644839644432068},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.19677826762199402},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.1746024787425995},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.15266406536102295},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.08664682507514954},{"id":"https://openalex.org/keywords/channel","display_name":"Channel (broadcasting)","score":0.0820871889591217}],"concepts":[{"id":"https://openalex.org/C2778562939","wikidata":"https://www.wikidata.org/wiki/Q1298791","display_name":"Synchronization (alternating current)","level":3,"score":0.8146982192993164},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7013913989067078},{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.5916810631752014},{"id":"https://openalex.org/C129891060","wikidata":"https://www.wikidata.org/wiki/Q1513059","display_name":"Clock synchronization","level":4,"score":0.5847969055175781},{"id":"https://openalex.org/C155837451","wikidata":"https://www.wikidata.org/wiki/Q1069144","display_name":"Clock drift","level":5,"score":0.5552828311920166},{"id":"https://openalex.org/C7720470","wikidata":"https://www.wikidata.org/wiki/Q954187","display_name":"Transceiver","level":3,"score":0.55442875623703},{"id":"https://openalex.org/C48939323","wikidata":"https://www.wikidata.org/wiki/Q294879","display_name":"Wake","level":2,"score":0.5293501019477844},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.5289497375488281},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.473423033952713},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.4536331593990326},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.4447006583213806},{"id":"https://openalex.org/C199822604","wikidata":"https://www.wikidata.org/wiki/Q557120","display_name":"Duty cycle","level":3,"score":0.4407261908054352},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3981893062591553},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.33724915981292725},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.21644839644432068},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.19677826762199402},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.1746024787425995},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.15266406536102295},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.08664682507514954},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.0820871889591217},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C146978453","wikidata":"https://www.wikidata.org/wiki/Q3798668","display_name":"Aerospace engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/softcom.2014.7039090","is_oa":false,"landing_page_url":"https://doi.org/10.1109/softcom.2014.7039090","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 22nd International Conference on Software, Telecommunications and Computer Networks (SoftCOM)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.9100000262260437}],"awards":[],"funders":[{"id":"https://openalex.org/F4320321114","display_name":"Bundesministerium f\u00fcr Bildung und Forschung","ror":"https://ror.org/04pz7b180"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":9,"referenced_works":["https://openalex.org/W5016201","https://openalex.org/W1976232261","https://openalex.org/W2018093989","https://openalex.org/W2143229717","https://openalex.org/W2147879203","https://openalex.org/W2170715240","https://openalex.org/W2171665783","https://openalex.org/W2949462958","https://openalex.org/W6600201090"],"related_works":["https://openalex.org/W2144712746","https://openalex.org/W3083853593","https://openalex.org/W1977555422","https://openalex.org/W2160540679","https://openalex.org/W3000741217","https://openalex.org/W2098880663","https://openalex.org/W3041897979","https://openalex.org/W1974603457","https://openalex.org/W1988298462","https://openalex.org/W2096966562"],"abstract_inverted_index":{"In":[0],"wireless":[1],"sensor":[2,17],"networks":[3],"(WSNs)":[4],"it":[5,23],"is":[6,24,71],"often":[7],"required":[8],"to":[9,20,26,31,55],"have":[10],"a":[11,56],"common":[12,34],"time":[13,35],"basis":[14],"for":[15],"all":[16],"nodes.":[18],"Due":[19],"clock":[21],"drift":[22],"necessary":[25],"re-synchronize":[27],"the":[28,33,52,72],"nodes":[29],"repeatedly":[30],"keep":[32],"basis.":[36],"But":[37],"this":[38],"re-synchronization":[39],"can":[40,50,66],"be":[41,67],"power":[42],"demanding.":[43],"We":[44],"present":[45],"an":[46],"energy-efficient":[47,74],"approach":[48,77],"which":[49],"bound":[51],"synchronization":[53],"error":[54],"certain":[57],"limit.":[58],"Either":[59],"duty-cycled":[60],"transceivers":[61],"or":[62],"wake-up":[63],"receivers":[64],"(WURs)":[65],"used.":[68],"Using":[69],"WURs":[70],"more":[73],"and":[75],"robust":[76],"but":[78],"needs":[79],"special":[80],"hardware.":[81]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2014,"cited_by_count":1}],"updated_date":"2026-03-25T13:04:00.132906","created_date":"2025-10-10T00:00:00"}
