{"id":"https://openalex.org/W4391307507","doi":"https://doi.org/10.1109/smc53992.2023.10394122","title":"A Wavelet Decomposition Network Based Edge Monitoring System for Classification of Electrical Equipment","display_name":"A Wavelet Decomposition Network Based Edge Monitoring System for Classification of Electrical Equipment","publication_year":2023,"publication_date":"2023-10-01","ids":{"openalex":"https://openalex.org/W4391307507","doi":"https://doi.org/10.1109/smc53992.2023.10394122"},"language":"en","primary_location":{"id":"doi:10.1109/smc53992.2023.10394122","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/smc53992.2023.10394122","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE International Conference on Systems, Man, and Cybernetics (SMC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5102705640","display_name":"Xianchen Wang","orcid":"https://orcid.org/0000-0002-8075-2370"},"institutions":[{"id":"https://openalex.org/I55712492","display_name":"Zhejiang University of Technology","ror":"https://ror.org/02djqfd08","country_code":"CN","type":"education","lineage":["https://openalex.org/I55712492"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Xianchen Wang","raw_affiliation_strings":["School of computer science and technology and software, Zhejiang University of Technology,Hangzhou,China","School of computer science and technology and software, Zhejiang University of Technology, Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"School of computer science and technology and software, Zhejiang University of Technology,Hangzhou,China","institution_ids":["https://openalex.org/I55712492"]},{"raw_affiliation_string":"School of computer science and technology and software, Zhejiang University of Technology, Hangzhou, China","institution_ids":["https://openalex.org/I55712492"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5069532193","display_name":"Di Cao","orcid":"https://orcid.org/0000-0003-0337-7930"},"institutions":[{"id":"https://openalex.org/I55712492","display_name":"Zhejiang University of Technology","ror":"https://ror.org/02djqfd08","country_code":"CN","type":"education","lineage":["https://openalex.org/I55712492"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Di Cao","raw_affiliation_strings":["School of computer science and technology and software, Zhejiang University of Technology,Hangzhou,China","School of computer science and technology and software, Zhejiang University of Technology, Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"School of computer science and technology and software, Zhejiang University of Technology,Hangzhou,China","institution_ids":["https://openalex.org/I55712492"]},{"raw_affiliation_string":"School of computer science and technology and software, Zhejiang University of Technology, Hangzhou, China","institution_ids":["https://openalex.org/I55712492"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5011289358","display_name":"Yiding Jiang","orcid":null},"institutions":[{"id":"https://openalex.org/I55712492","display_name":"Zhejiang University of Technology","ror":"https://ror.org/02djqfd08","country_code":"CN","type":"education","lineage":["https://openalex.org/I55712492"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yiding Jiang","raw_affiliation_strings":["School of computer science and technology and software, Zhejiang University of Technology,Hangzhou,China","School of computer science and technology and software, Zhejiang University of Technology, Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"School of computer science and technology and software, Zhejiang University of Technology,Hangzhou,China","institution_ids":["https://openalex.org/I55712492"]},{"raw_affiliation_string":"School of computer science and technology and software, Zhejiang University of Technology, Hangzhou, China","institution_ids":["https://openalex.org/I55712492"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5010168982","display_name":"Yanjing Lei","orcid":"https://orcid.org/0000-0003-0580-8941"},"institutions":[{"id":"https://openalex.org/I55712492","display_name":"Zhejiang University of Technology","ror":"https://ror.org/02djqfd08","country_code":"CN","type":"education","lineage":["https://openalex.org/I55712492"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yanjing Lei","raw_affiliation_strings":["School of computer science and technology and software, Zhejiang University of Technology,Hangzhou,China","School of computer science and technology and software, Zhejiang University of Technology, Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"School of computer science and technology and software, Zhejiang University of Technology,Hangzhou,China","institution_ids":["https://openalex.org/I55712492"]},{"raw_affiliation_string":"School of computer science and technology and software, Zhejiang University of Technology, Hangzhou, China","institution_ids":["https://openalex.org/I55712492"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5008958710","display_name":"Linghao Ying","orcid":"https://orcid.org/0009-0004-3819-8849"},"institutions":[{"id":"https://openalex.org/I55712492","display_name":"Zhejiang University of Technology","ror":"https://ror.org/02djqfd08","country_code":"CN","type":"education","lineage":["https://openalex.org/I55712492"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Linghao Ying","raw_affiliation_strings":["School of computer science and technology and software, Zhejiang University of Technology,Hangzhou,China","School of computer science and technology and software, Zhejiang University of Technology, Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"School of computer science and technology and software, Zhejiang University of Technology,Hangzhou,China","institution_ids":["https://openalex.org/I55712492"]},{"raw_affiliation_string":"School of computer science and technology and software, Zhejiang University of Technology, Hangzhou, China","institution_ids":["https://openalex.org/I55712492"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5102705640"],"corresponding_institution_ids":["https://openalex.org/I55712492"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.18662484,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"7","last_page":"12"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11052","display_name":"Energy Load and Power Forecasting","score":0.9934999942779541,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9846000075340271,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6711395382881165},{"id":"https://openalex.org/keywords/electric-potential-energy","display_name":"Electric potential energy","score":0.6553282737731934},{"id":"https://openalex.org/keywords/wavelet","display_name":"Wavelet","score":0.6069410443305969},{"id":"https://openalex.org/keywords/wavelet-transform","display_name":"Wavelet transform","score":0.579295814037323},{"id":"https://openalex.org/keywords/enhanced-data-rates-for-gsm-evolution","display_name":"Enhanced Data Rates for GSM Evolution","score":0.5570971369743347},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.5323249101638794},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.5300195813179016},{"id":"https://openalex.org/keywords/electrical-equipment","display_name":"Electrical equipment","score":0.4991750717163086},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.4772786498069763},{"id":"https://openalex.org/keywords/electrical-network","display_name":"Electrical network","score":0.4720633327960968},{"id":"https://openalex.org/keywords/electrical-load","display_name":"Electrical load","score":0.46508851647377014},{"id":"https://openalex.org/keywords/decomposition","display_name":"Decomposition","score":0.4374869465827942},{"id":"https://openalex.org/keywords/identification","display_name":"Identification (biology)","score":0.41761332750320435},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.4153999388217926},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.33893921971321106},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.26976650953292847},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.19539442658424377},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.159114807844162}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6711395382881165},{"id":"https://openalex.org/C98576551","wikidata":"https://www.wikidata.org/wiki/Q841798","display_name":"Electric potential energy","level":3,"score":0.6553282737731934},{"id":"https://openalex.org/C47432892","wikidata":"https://www.wikidata.org/wiki/Q831390","display_name":"Wavelet","level":2,"score":0.6069410443305969},{"id":"https://openalex.org/C196216189","wikidata":"https://www.wikidata.org/wiki/Q2867","display_name":"Wavelet transform","level":3,"score":0.579295814037323},{"id":"https://openalex.org/C162307627","wikidata":"https://www.wikidata.org/wiki/Q204833","display_name":"Enhanced Data Rates for GSM Evolution","level":2,"score":0.5570971369743347},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.5323249101638794},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.5300195813179016},{"id":"https://openalex.org/C162175671","wikidata":"https://www.wikidata.org/wiki/Q3749263","display_name":"Electrical equipment","level":2,"score":0.4991750717163086},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.4772786498069763},{"id":"https://openalex.org/C196796808","wikidata":"https://www.wikidata.org/wiki/Q132629","display_name":"Electrical network","level":2,"score":0.4720633327960968},{"id":"https://openalex.org/C77715397","wikidata":"https://www.wikidata.org/wiki/Q931447","display_name":"Electrical load","level":3,"score":0.46508851647377014},{"id":"https://openalex.org/C124681953","wikidata":"https://www.wikidata.org/wiki/Q339062","display_name":"Decomposition","level":2,"score":0.4374869465827942},{"id":"https://openalex.org/C116834253","wikidata":"https://www.wikidata.org/wiki/Q2039217","display_name":"Identification (biology)","level":2,"score":0.41761332750320435},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.4153999388217926},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.33893921971321106},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.26976650953292847},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.19539442658424377},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.159114807844162},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C59822182","wikidata":"https://www.wikidata.org/wiki/Q441","display_name":"Botany","level":1,"score":0.0},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.0},{"id":"https://openalex.org/C18903297","wikidata":"https://www.wikidata.org/wiki/Q7150","display_name":"Ecology","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/smc53992.2023.10394122","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/smc53992.2023.10394122","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE International Conference on Systems, Man, and Cybernetics (SMC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":21,"referenced_works":["https://openalex.org/W1557760704","https://openalex.org/W1850325679","https://openalex.org/W2050222808","https://openalex.org/W2123910460","https://openalex.org/W2132984323","https://openalex.org/W2222435693","https://openalex.org/W2416799949","https://openalex.org/W2543031169","https://openalex.org/W2551393996","https://openalex.org/W2583466634","https://openalex.org/W2731010577","https://openalex.org/W2755958508","https://openalex.org/W2764060181","https://openalex.org/W2791335002","https://openalex.org/W2808955427","https://openalex.org/W2910886069","https://openalex.org/W2972684890","https://openalex.org/W2981331378","https://openalex.org/W3090610511","https://openalex.org/W6638444622","https://openalex.org/W6740609221"],"related_works":["https://openalex.org/W4213300803","https://openalex.org/W2560638541","https://openalex.org/W2391477214","https://openalex.org/W2232319630","https://openalex.org/W4307984918","https://openalex.org/W3157864582","https://openalex.org/W2995583419","https://openalex.org/W4323056393","https://openalex.org/W4380897818","https://openalex.org/W2810202497"],"abstract_inverted_index":{"As":[0],"the":[1,13,16,74,118,129],"growth":[2],"number":[3],"of":[4,15,104,115,126,139],"electrical":[5,17,61,105,131],"appliances":[6,67],"used":[7,54],"in":[8,73],"industry":[9],"and":[10,65,77,122],"household,":[11],"identifying":[12],"categories":[14],"devices":[18],"act":[19],"as":[20],"a":[21,70,97,135],"priority":[22],"to":[23,44],"enable":[24],"an":[25,92,112,123],"intelligent":[26],"management":[27,40],"system":[28,95],"for":[29,38,55,85,102],"electricity":[30],"consumption.":[31],"Appliance":[32],"load":[33],"monitoring":[34,94],"(ALM)":[35],"is":[36],"essential":[37],"energy":[39,47,57],"solutions,":[41],"allowing":[42],"them":[43],"obtain":[45],"appliance-specific":[46],"consumption":[48],"statistics":[49],"that":[50],"can":[51,110],"further":[52],"be":[53],"optimal":[56],"utilization.":[58],"However,":[59],"collecting":[60],"features":[62],"from":[63],"numerous":[64],"multivariate":[66],"may":[68],"cause":[69],"high":[71],"burden":[72],"communication":[75],"network":[76,101],"existing":[78],"identification":[79],"methods":[80],"do":[81],"not":[82],"perform":[83],"well":[84],"online":[86],"monitoring.":[87],"Thus,":[88],"this":[89],"paper":[90],"proposed":[91,108],"edge":[93],"with":[96,134],"multilevel":[98],"wavelet":[99],"decomposition":[100],"classification":[103],"appliances.":[106],"The":[107],"model":[109],"achieve":[111],"average":[113],"error":[114,124],"1.4%":[116],"on":[117,128],"UCR":[119],"public":[120],"dataset":[121,133],"rate":[125],"2.7%":[127],"self-built":[130],"appliance":[132],"maximum":[136],"service":[137],"delay":[138],"50":[140],"milliseconds.":[141]},"counts_by_year":[],"updated_date":"2025-12-22T23:10:17.713674","created_date":"2025-10-10T00:00:00"}
