{"id":"https://openalex.org/W2775690100","doi":"https://doi.org/10.1109/smc.2017.8123077","title":"Correlation analysis of heart rate variability between PPG and ECG for wearable devices in different postures","display_name":"Correlation analysis of heart rate variability between PPG and ECG for wearable devices in different postures","publication_year":2017,"publication_date":"2017-10-01","ids":{"openalex":"https://openalex.org/W2775690100","doi":"https://doi.org/10.1109/smc.2017.8123077","mag":"2775690100"},"language":"en","primary_location":{"id":"doi:10.1109/smc.2017.8123077","is_oa":false,"landing_page_url":"https://doi.org/10.1109/smc.2017.8123077","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE International Conference on Systems, Man, and Cybernetics (SMC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101108269","display_name":"Chun-Chieh Hsiao","orcid":null},"institutions":[{"id":"https://openalex.org/I50519452","display_name":"Lunghwa University of Science and Technology","ror":"https://ror.org/001y2wd07","country_code":"TW","type":"education","lineage":["https://openalex.org/I50519452"]},{"id":"https://openalex.org/I16733864","display_name":"National Taiwan University","ror":"https://ror.org/05bqach95","country_code":"TW","type":"education","lineage":["https://openalex.org/I16733864"]}],"countries":["TW"],"is_corresponding":true,"raw_author_name":"Chun-Chieh Hsiao","raw_affiliation_strings":["Department of Computer Information and Network Engineering, Lunghwa University of Science and Technology","Department of Electrical Engineering, National Taiwan University"],"affiliations":[{"raw_affiliation_string":"Department of Computer Information and Network Engineering, Lunghwa University of Science and Technology","institution_ids":["https://openalex.org/I50519452"]},{"raw_affiliation_string":"Department of Electrical Engineering, National Taiwan University","institution_ids":["https://openalex.org/I16733864"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5077028671","display_name":"Fang-Wei Hsu","orcid":null},"institutions":[{"id":"https://openalex.org/I118292597","display_name":"National Taipei University of Technology","ror":"https://ror.org/00cn92c09","country_code":"TW","type":"education","lineage":["https://openalex.org/I118292597"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Fang-Wei Hsu","raw_affiliation_strings":["Department of Electronic Engineering, National Taipei University of Technology"],"affiliations":[{"raw_affiliation_string":"Department of Electronic Engineering, National Taipei University of Technology","institution_ids":["https://openalex.org/I118292597"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5056595228","display_name":"Ren-Guey Lee","orcid":null},"institutions":[{"id":"https://openalex.org/I118292597","display_name":"National Taipei University of Technology","ror":"https://ror.org/00cn92c09","country_code":"TW","type":"education","lineage":["https://openalex.org/I118292597"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Ren-Guey Lee","raw_affiliation_strings":["Department of Electronic Engineering, National Taipei University of Technology"],"affiliations":[{"raw_affiliation_string":"Department of Electronic Engineering, National Taipei University of Technology","institution_ids":["https://openalex.org/I118292597"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5111813735","display_name":"Robert Lin","orcid":null},"institutions":[{"id":"https://openalex.org/I50519452","display_name":"Lunghwa University of Science and Technology","ror":"https://ror.org/001y2wd07","country_code":"TW","type":"education","lineage":["https://openalex.org/I50519452"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Robert Lin","raw_affiliation_strings":["Department of Electrical Engineering, Lunghwa University of Science and Technology"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Lunghwa University of Science and Technology","institution_ids":["https://openalex.org/I50519452"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5101108269"],"corresponding_institution_ids":["https://openalex.org/I16733864","https://openalex.org/I50519452"],"apc_list":null,"apc_paid":null,"fwci":0.7007,"has_fulltext":false,"cited_by_count":21,"citation_normalized_percentile":{"value":0.74854231,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":null,"issue":null,"first_page":"2957","last_page":"2962"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10745","display_name":"Heart Rate Variability and Autonomic Control","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10745","display_name":"Heart Rate Variability and Autonomic Control","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9950000047683716,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/photoplethysmogram","display_name":"Photoplethysmogram","score":0.8416033983230591},{"id":"https://openalex.org/keywords/heart-rate-variability","display_name":"Heart rate variability","score":0.7438289523124695},{"id":"https://openalex.org/keywords/correlation","display_name":"Correlation","score":0.6687264442443848},{"id":"https://openalex.org/keywords/correlation-coefficient","display_name":"Correlation coefficient","score":0.6238728761672974},{"id":"https://openalex.org/keywords/pearson-product-moment-correlation-coefficient","display_name":"Pearson product-moment correlation coefficient","score":0.47366175055503845},{"id":"https://openalex.org/keywords/electrocardiography","display_name":"Electrocardiography","score":0.43863677978515625},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.43332308530807495},{"id":"https://openalex.org/keywords/noise","display_name":"Noise (video)","score":0.4232887625694275},{"id":"https://openalex.org/keywords/cardiology","display_name":"Cardiology","score":0.38507720828056335},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3752223253250122},{"id":"https://openalex.org/keywords/heart-rate","display_name":"Heart rate","score":0.37164759635925293},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.3140749931335449},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.29749488830566406},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.2846929430961609},{"id":"https://openalex.org/keywords/internal-medicine","display_name":"Internal medicine","score":0.23641175031661987},{"id":"https://openalex.org/keywords/statistics","display_name":"Statistics","score":0.20832830667495728},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.12105002999305725},{"id":"https://openalex.org/keywords/blood-pressure","display_name":"Blood pressure","score":0.10408762097358704},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.0988013744354248}],"concepts":[{"id":"https://openalex.org/C116390426","wikidata":"https://www.wikidata.org/wiki/Q7187885","display_name":"Photoplethysmogram","level":3,"score":0.8416033983230591},{"id":"https://openalex.org/C71635504","wikidata":"https://www.wikidata.org/wiki/Q933954","display_name":"Heart rate variability","level":4,"score":0.7438289523124695},{"id":"https://openalex.org/C117220453","wikidata":"https://www.wikidata.org/wiki/Q5172842","display_name":"Correlation","level":2,"score":0.6687264442443848},{"id":"https://openalex.org/C2780092901","wikidata":"https://www.wikidata.org/wiki/Q3433612","display_name":"Correlation coefficient","level":2,"score":0.6238728761672974},{"id":"https://openalex.org/C55078378","wikidata":"https://www.wikidata.org/wiki/Q1136628","display_name":"Pearson product-moment correlation coefficient","level":2,"score":0.47366175055503845},{"id":"https://openalex.org/C2780040984","wikidata":"https://www.wikidata.org/wiki/Q79785","display_name":"Electrocardiography","level":2,"score":0.43863677978515625},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.43332308530807495},{"id":"https://openalex.org/C99498987","wikidata":"https://www.wikidata.org/wiki/Q2210247","display_name":"Noise (video)","level":3,"score":0.4232887625694275},{"id":"https://openalex.org/C164705383","wikidata":"https://www.wikidata.org/wiki/Q10379","display_name":"Cardiology","level":1,"score":0.38507720828056335},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3752223253250122},{"id":"https://openalex.org/C2777953023","wikidata":"https://www.wikidata.org/wiki/Q1073121","display_name":"Heart rate","level":3,"score":0.37164759635925293},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.3140749931335449},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.29749488830566406},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.2846929430961609},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.23641175031661987},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.20832830667495728},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.12105002999305725},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.10408762097358704},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.0988013744354248},{"id":"https://openalex.org/C115961682","wikidata":"https://www.wikidata.org/wiki/Q860623","display_name":"Image (mathematics)","level":2,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/smc.2017.8123077","is_oa":false,"landing_page_url":"https://doi.org/10.1109/smc.2017.8123077","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE International Conference on Systems, Man, and Cybernetics (SMC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Good health and well-being","id":"https://metadata.un.org/sdg/3","score":0.8100000023841858}],"awards":[],"funders":[{"id":"https://openalex.org/F4320323900","display_name":"National Taiwan University","ror":"https://ror.org/05bqach95"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":8,"referenced_works":["https://openalex.org/W2014229115","https://openalex.org/W2020534369","https://openalex.org/W2058806221","https://openalex.org/W2060083322","https://openalex.org/W2063685379","https://openalex.org/W2122721153","https://openalex.org/W2285072859","https://openalex.org/W6678472974"],"related_works":["https://openalex.org/W3196000489","https://openalex.org/W2092419518","https://openalex.org/W1489924780","https://openalex.org/W2135573418","https://openalex.org/W2138353306","https://openalex.org/W357196361","https://openalex.org/W2027314909","https://openalex.org/W1036938216","https://openalex.org/W3109425891","https://openalex.org/W2113714434"],"abstract_inverted_index":{"In":[0],"this":[1],"study,":[2],"correlation":[3,120,137,143,177],"of":[4,26,33,49,112,117,125,147,161,184,207],"heart":[5,37,209],"rate":[6],"variability":[7],"(HRV)":[8],"results":[9,103,111,124,160],"in":[10,52,106,141,203],"different":[11,107],"postures":[12],"between":[13],"ECG-based":[14,99],"and":[15,36,55,64,72,133,139,169],"PPG-based":[16,84],"cardiac":[17],"measurement":[18,185],"devices":[19],"is":[20,24,56,93,151,210],"explored.":[21],"Electrocardiogram":[22],"(ECG)":[23],"one":[25],"the":[27,31,47,53,82,87,96,109,122,126,136,148,166,182,199,204,208],"best":[28],"indicators":[29],"for":[30],"assessment":[32],"physical":[34],"health":[35],"function,":[38],"while":[39,86],"photoplethysmography":[40],"(PPG)":[41],"uses":[42],"light":[43],"sensor":[44],"to":[45,60],"detect":[46],"change":[48],"blood":[50],"volume":[51],"vessel,":[54],"thus":[57],"less":[58],"susceptible":[59],"power":[61],"supply":[62],"noise":[63],"electromagnetic":[65],"interference.":[66],"Our":[67],"wearable":[68],"prototype":[69,115,164],"Z1":[70,114,156,163,188],"Wristband":[71],"commercially":[73],"available":[74],"Mio":[75,149],"Alpha":[76,150],"HR":[77],"watch":[78],"are":[79,116],"chosen":[80,94],"as":[81,95],"target":[83,97],"devices,":[85],"medical":[88],"12-lead":[89],"Poly-Spectrum-12/E":[90],"ECG":[91,127],"monitor":[92],"(benchmark)":[98],"device.":[100],"The":[101,145,158,196],"experimental":[102],"shows":[104,181],"that":[105,214],"postures,":[108],"HRV":[110,123,159],"our":[113,155,162,187],"significant":[118,175],"positive":[119,176],"with":[121,186,198,201,215],"device":[128],"(r>0.861,":[129],"p<;0.01)":[130,179],"where":[131],"r":[132],"p":[134],"represent":[135],"coefficient":[138],"p-value":[140],"Pearson's":[142],"analysis.":[144],"performance":[146,197],"slightly":[152,211],"worse":[153],"than":[154,213],"prototype.":[157],"on":[165],"right":[167,191],"hand":[168,171,192],"left":[170,194],"also":[172],"show":[173],"a":[174],"(r>0.970,":[178],"which":[180],"feasibility":[183],"via":[189],"either":[190],"or":[193],"hand.":[195],"posture":[200],"hands":[202,216],"same":[205],"height":[206],"better":[212],"drooping.":[217]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":5},{"year":2022,"cited_by_count":5},{"year":2021,"cited_by_count":3},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":2},{"year":2018,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
