{"id":"https://openalex.org/W4415398926","doi":"https://doi.org/10.1109/smartgridcomm65349.2025.11204614","title":"Optimal Operation Strategies for Active Distribution Networks Considering the Data Center Demand Response","display_name":"Optimal Operation Strategies for Active Distribution Networks Considering the Data Center Demand Response","publication_year":2025,"publication_date":"2025-09-29","ids":{"openalex":"https://openalex.org/W4415398926","doi":"https://doi.org/10.1109/smartgridcomm65349.2025.11204614"},"language":null,"primary_location":{"id":"doi:10.1109/smartgridcomm65349.2025.11204614","is_oa":false,"landing_page_url":"https://doi.org/10.1109/smartgridcomm65349.2025.11204614","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE International Conference on Communications, Control, and Computing Technologies for Smart Grids (SmartGridComm)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5106028635","display_name":"Zhenxiang Xing","orcid":"https://orcid.org/0000-0002-1094-9434"},"institutions":[{"id":"https://openalex.org/I4210116924","display_name":"Chinese University of Hong Kong, Shenzhen","ror":"https://ror.org/02d5ks197","country_code":"CN","type":"education","lineage":["https://openalex.org/I177725633","https://openalex.org/I180726961","https://openalex.org/I4210116924"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Zhixiang Xing","raw_affiliation_strings":["The Chinese University of Hong Kong, Shenzhen,School of Science and Engineering,Shenzhen,China"],"affiliations":[{"raw_affiliation_string":"The Chinese University of Hong Kong, Shenzhen,School of Science and Engineering,Shenzhen,China","institution_ids":["https://openalex.org/I4210116924"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101183731","display_name":"Zhendong Yang","orcid":null},"institutions":[{"id":"https://openalex.org/I90610280","display_name":"South China University of Technology","ror":"https://ror.org/0530pts50","country_code":"CN","type":"education","lineage":["https://openalex.org/I90610280"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhendong Yang","raw_affiliation_strings":["South China University of Technology,School of Electric Power Engineering,Guangzhou,China"],"affiliations":[{"raw_affiliation_string":"South China University of Technology,School of Electric Power Engineering,Guangzhou,China","institution_ids":["https://openalex.org/I90610280"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100363813","display_name":"Zhigang Li","orcid":"https://orcid.org/0000-0003-0464-8800"},"institutions":[{"id":"https://openalex.org/I4210116924","display_name":"Chinese University of Hong Kong, Shenzhen","ror":"https://ror.org/02d5ks197","country_code":"CN","type":"education","lineage":["https://openalex.org/I177725633","https://openalex.org/I180726961","https://openalex.org/I4210116924"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhigang Li","raw_affiliation_strings":["The Chinese University of Hong Kong, Shenzhen,School of Science and Engineering,Shenzhen,China"],"affiliations":[{"raw_affiliation_string":"The Chinese University of Hong Kong, Shenzhen,School of Science and Engineering,Shenzhen,China","institution_ids":["https://openalex.org/I4210116924"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5078533788","display_name":"Danyang Xu","orcid":null},"institutions":[{"id":"https://openalex.org/I162868743","display_name":"Tianjin University","ror":"https://ror.org/012tb2g32","country_code":"CN","type":"education","lineage":["https://openalex.org/I162868743"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Danyang Xu","raw_affiliation_strings":["Engineering Tianjin University,School of Electrical and Information,China"],"affiliations":[{"raw_affiliation_string":"Engineering Tianjin University,School of Electrical and Information,China","institution_ids":["https://openalex.org/I162868743"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5089279497","display_name":"Jiehui Zheng","orcid":"https://orcid.org/0000-0003-4928-6524"},"institutions":[{"id":"https://openalex.org/I90610280","display_name":"South China University of Technology","ror":"https://ror.org/0530pts50","country_code":"CN","type":"education","lineage":["https://openalex.org/I90610280"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"J. H. Zheng","raw_affiliation_strings":["South China University of Technology,School of Electric Power Engineering,Guangzhou,China"],"affiliations":[{"raw_affiliation_string":"South China University of Technology,School of Electric Power Engineering,Guangzhou,China","institution_ids":["https://openalex.org/I90610280"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5106028635"],"corresponding_institution_ids":["https://openalex.org/I4210116924"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.32065395,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9959999918937683,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9959999918937683,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9677000045776367,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9648000001907349,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/dynamic-pricing","display_name":"Dynamic pricing","score":0.6668999791145325},{"id":"https://openalex.org/keywords/data-center","display_name":"Data center","score":0.664900004863739},{"id":"https://openalex.org/keywords/demand-response","display_name":"Demand response","score":0.6498000025749207},{"id":"https://openalex.org/keywords/flexibility","display_name":"Flexibility (engineering)","score":0.6316999793052673},{"id":"https://openalex.org/keywords/bilevel-optimization","display_name":"Bilevel optimization","score":0.5228999853134155},{"id":"https://openalex.org/keywords/nash-equilibrium","display_name":"Nash equilibrium","score":0.47600001096725464},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.4438999891281128},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.4334999918937683},{"id":"https://openalex.org/keywords/dynamic-demand","display_name":"Dynamic demand","score":0.40860000252723694},{"id":"https://openalex.org/keywords/best-response","display_name":"Best response","score":0.4059999883174896}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6811000108718872},{"id":"https://openalex.org/C2779391423","wikidata":"https://www.wikidata.org/wiki/Q17009728","display_name":"Dynamic pricing","level":2,"score":0.6668999791145325},{"id":"https://openalex.org/C153740404","wikidata":"https://www.wikidata.org/wiki/Q671224","display_name":"Data center","level":2,"score":0.664900004863739},{"id":"https://openalex.org/C2779438525","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Demand response","level":3,"score":0.6498000025749207},{"id":"https://openalex.org/C2780598303","wikidata":"https://www.wikidata.org/wiki/Q65921492","display_name":"Flexibility (engineering)","level":2,"score":0.6316999793052673},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.5275999903678894},{"id":"https://openalex.org/C3309286","wikidata":"https://www.wikidata.org/wiki/Q4907693","display_name":"Bilevel optimization","level":3,"score":0.5228999853134155},{"id":"https://openalex.org/C46814582","wikidata":"https://www.wikidata.org/wiki/Q23389","display_name":"Nash equilibrium","level":2,"score":0.47600001096725464},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.4438999891281128},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.4334999918937683},{"id":"https://openalex.org/C45872418","wikidata":"https://www.wikidata.org/wiki/Q5318966","display_name":"Dynamic demand","level":3,"score":0.40860000252723694},{"id":"https://openalex.org/C32407928","wikidata":"https://www.wikidata.org/wiki/Q2733833","display_name":"Best response","level":3,"score":0.4059999883174896},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.39750000834465027},{"id":"https://openalex.org/C42475967","wikidata":"https://www.wikidata.org/wiki/Q194292","display_name":"Operations research","level":1,"score":0.39570000767707825},{"id":"https://openalex.org/C195487862","wikidata":"https://www.wikidata.org/wiki/Q850210","display_name":"Revenue","level":2,"score":0.3928000032901764},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.384799987077713},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.3772999942302704},{"id":"https://openalex.org/C2779370713","wikidata":"https://www.wikidata.org/wiki/Q357554","display_name":"Load management","level":2,"score":0.3709999918937683},{"id":"https://openalex.org/C206345919","wikidata":"https://www.wikidata.org/wiki/Q20380951","display_name":"Resource (disambiguation)","level":2,"score":0.3698999881744385},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3686000108718872},{"id":"https://openalex.org/C2781463594","wikidata":"https://www.wikidata.org/wiki/Q1229659","display_name":"Distribution center","level":2,"score":0.3621000051498413},{"id":"https://openalex.org/C2780440489","wikidata":"https://www.wikidata.org/wiki/Q5227278","display_name":"Data-driven","level":2,"score":0.3361999988555908},{"id":"https://openalex.org/C159694833","wikidata":"https://www.wikidata.org/wiki/Q2321565","display_name":"Iterative method","level":2,"score":0.3224000036716461},{"id":"https://openalex.org/C177142836","wikidata":"https://www.wikidata.org/wiki/Q44455","display_name":"Game theory","level":2,"score":0.32109999656677246},{"id":"https://openalex.org/C197298091","wikidata":"https://www.wikidata.org/wiki/Q5318963","display_name":"Dynamic data","level":2,"score":0.31279999017715454},{"id":"https://openalex.org/C67186912","wikidata":"https://www.wikidata.org/wiki/Q367664","display_name":"Data modeling","level":2,"score":0.31119999289512634},{"id":"https://openalex.org/C2779280359","wikidata":"https://www.wikidata.org/wiki/Q870344","display_name":"Electricity pricing","level":4,"score":0.3075000047683716},{"id":"https://openalex.org/C2983254600","wikidata":"https://www.wikidata.org/wiki/Q1096907","display_name":"Power grid","level":3,"score":0.3061999976634979},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.2919999957084656},{"id":"https://openalex.org/C110121322","wikidata":"https://www.wikidata.org/wiki/Q865811","display_name":"Distribution (mathematics)","level":2,"score":0.28189998865127563},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.2815000116825104},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.2696000039577484},{"id":"https://openalex.org/C2781260460","wikidata":"https://www.wikidata.org/wiki/Q6139999","display_name":"Energy management system","level":4,"score":0.2669000029563904}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/smartgridcomm65349.2025.11204614","is_oa":false,"landing_page_url":"https://doi.org/10.1109/smartgridcomm65349.2025.11204614","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE International Conference on Communications, Control, and Computing Technologies for Smart Grids (SmartGridComm)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W1971726541","https://openalex.org/W1973100921","https://openalex.org/W1985688982","https://openalex.org/W2033202841","https://openalex.org/W2093909370","https://openalex.org/W2243705582","https://openalex.org/W2567859247","https://openalex.org/W2951280726","https://openalex.org/W4205423084","https://openalex.org/W4211238852","https://openalex.org/W4390938819","https://openalex.org/W4405647885","https://openalex.org/W4408413091"],"related_works":[],"abstract_inverted_index":{"As":[0],"the":[1,25,28,107],"conflict":[2],"between":[3,43,106],"high-energy-consumption":[4],"data":[5,16,44,62,111,129],"centers":[6,17,45],"and":[7,46,51,60,98,110,118],"power":[8,47,108],"system":[9,109],"flexibility":[10],"becomes":[11],"increasingly":[12],"pronounced,":[13],"developing":[14],"grid-friendly":[15],"has":[18],"emerged":[19],"as":[20],"a":[21,81,99,120],"critical":[22],"challenge":[23],"in":[24],"evolution":[26],"of":[27,54],"energy":[29],"internet.":[30],"Although":[31],"recent":[32],"studies":[33],"have":[34],"made":[35],"some":[36],"progress,":[37],"they":[38],"still":[39],"lack":[40],"effective":[41],"coordination":[42],"systems.":[48],"The":[49],"physical":[50],"operation":[52],"constraints":[53],"distribution":[55],"networks":[56],"are":[57],"often":[58],"neglected,":[59],"most":[61],"center":[63,112,130],"demand":[64],"response":[65],"schemes":[66],"do":[67],"not":[68],"account":[69],"for":[70],"dynamic":[71,86],"electricity":[72],"pricing.":[73],"To":[74],"address":[75],"these":[76],"issues,":[77],"this":[78],"paper":[79],"proposes":[80],"collaborative":[82],"framework":[83],"that":[84,123],"integrates":[85],"pricing":[87],"with":[88],"spatiotemporal":[89],"load":[90],"migration.":[91],"We":[92],"introduce":[93],"an":[94],"improved":[95],"DistFlow":[96],"model":[97],"bilevel":[100],"iterative":[101],"algorithm":[102],"to":[103],"establish":[104],"equilibrium":[105,122],"clusters,":[113],"thereby":[114],"coordinating":[115],"resource":[116],"loads":[117],"achieving":[119],"Nash":[121],"maximizes":[124],"grid":[125],"revenue":[126],"while":[127],"minimizing":[128],"operating":[131],"costs.":[132]},"counts_by_year":[],"updated_date":"2026-03-07T16:01:11.037858","created_date":"2025-10-22T00:00:00"}
