{"id":"https://openalex.org/W2902262592","doi":"https://doi.org/10.1109/smartgridcomm.2018.8587491","title":"On the Impact of Synchronization Attacks on Distributed and Cooperative Control in Microgrid Systems","display_name":"On the Impact of Synchronization Attacks on Distributed and Cooperative Control in Microgrid Systems","publication_year":2018,"publication_date":"2018-10-01","ids":{"openalex":"https://openalex.org/W2902262592","doi":"https://doi.org/10.1109/smartgridcomm.2018.8587491","mag":"2902262592"},"language":"en","primary_location":{"id":"doi:10.1109/smartgridcomm.2018.8587491","is_oa":false,"landing_page_url":"https://doi.org/10.1109/smartgridcomm.2018.8587491","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE International Conference on Communications, Control, and Computing Technologies for Smart Grids (SmartGridComm)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://inria.hal.science/hal-01870771","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100541138","display_name":"Mingxiao Ma","orcid":"https://orcid.org/0000-0001-7603-2138"},"institutions":[{"id":"https://openalex.org/I4210121838","display_name":"Laboratoire Lorrain de Recherche en Informatique et ses Applications","ror":"https://ror.org/02vnf0c38","country_code":"FR","type":"facility","lineage":["https://openalex.org/I1294671590","https://openalex.org/I1294671590","https://openalex.org/I1326498283","https://openalex.org/I277688954","https://openalex.org/I4210107720","https://openalex.org/I4210121838","https://openalex.org/I4210159245","https://openalex.org/I90183372"]},{"id":"https://openalex.org/I4210140143","display_name":"Dynamic Systems (United States)","ror":"https://ror.org/043vm9914","country_code":"US","type":"company","lineage":["https://openalex.org/I4210140143"]},{"id":"https://openalex.org/I90183372","display_name":"Universit\u00e9 de Lorraine","ror":"https://ror.org/04vfs2w97","country_code":"FR","type":"education","lineage":["https://openalex.org/I90183372"]}],"countries":["FR","US"],"is_corresponding":false,"raw_author_name":"Mingxiao Ma","raw_affiliation_strings":["Universit\u00e9 de Lorraine, Nancy, France","Laboratoire Lorrain de Recherche en Informatique et ses Applications","Resilience and Elasticity for Security and ScalabiliTy of dynamic networked systems"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universit\u00e9 de Lorraine, Nancy, France","institution_ids":["https://openalex.org/I90183372"]},{"raw_affiliation_string":"Laboratoire Lorrain de Recherche en Informatique et ses Applications","institution_ids":["https://openalex.org/I4210121838"]},{"raw_affiliation_string":"Resilience and Elasticity for Security and ScalabiliTy of dynamic networked systems","institution_ids":["https://openalex.org/I4210140143"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5111932337","display_name":"Abdelkader Lahmadi","orcid":null},"institutions":[{"id":"https://openalex.org/I4210121838","display_name":"Laboratoire Lorrain de Recherche en Informatique et ses Applications","ror":"https://ror.org/02vnf0c38","country_code":"FR","type":"facility","lineage":["https://openalex.org/I1294671590","https://openalex.org/I1294671590","https://openalex.org/I1326498283","https://openalex.org/I277688954","https://openalex.org/I4210107720","https://openalex.org/I4210121838","https://openalex.org/I4210159245","https://openalex.org/I90183372"]},{"id":"https://openalex.org/I4210140143","display_name":"Dynamic Systems (United States)","ror":"https://ror.org/043vm9914","country_code":"US","type":"company","lineage":["https://openalex.org/I4210140143"]},{"id":"https://openalex.org/I90183372","display_name":"Universit\u00e9 de Lorraine","ror":"https://ror.org/04vfs2w97","country_code":"FR","type":"education","lineage":["https://openalex.org/I90183372"]}],"countries":["FR","US"],"is_corresponding":false,"raw_author_name":"Abdelkader Lahmadi","raw_affiliation_strings":["Universit\u00e9 de Lorraine, Nancy, France","Laboratoire Lorrain de Recherche en Informatique et ses Applications","Resilience and Elasticity for Security and ScalabiliTy of dynamic networked systems"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universit\u00e9 de Lorraine, Nancy, France","institution_ids":["https://openalex.org/I90183372"]},{"raw_affiliation_string":"Laboratoire Lorrain de Recherche en Informatique et ses Applications","institution_ids":["https://openalex.org/I4210121838"]},{"raw_affiliation_string":"Resilience and Elasticity for Security and ScalabiliTy of dynamic networked systems","institution_ids":["https://openalex.org/I4210140143"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":10,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9775000214576721,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.9683202505111694},{"id":"https://openalex.org/keywords/synchronization","display_name":"Synchronization (alternating current)","score":0.7270990610122681},{"id":"https://openalex.org/keywords/scalability","display_name":"Scalability","score":0.653322160243988},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6381471753120422},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.5900266766548157},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.5265218019485474},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.4760953187942505},{"id":"https://openalex.org/keywords/decentralised-system","display_name":"Decentralised system","score":0.4690093696117401},{"id":"https://openalex.org/keywords/telecommunications-network","display_name":"Telecommunications network","score":0.443971186876297},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.43130651116371155},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.4286551773548126},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.4282231330871582},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.3929106295108795},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.33218643069267273},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.23162305355072021},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.12203049659729004}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.9683202505111694},{"id":"https://openalex.org/C2778562939","wikidata":"https://www.wikidata.org/wiki/Q1298791","display_name":"Synchronization (alternating current)","level":3,"score":0.7270990610122681},{"id":"https://openalex.org/C48044578","wikidata":"https://www.wikidata.org/wiki/Q727490","display_name":"Scalability","level":2,"score":0.653322160243988},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6381471753120422},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.5900266766548157},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.5265218019485474},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.4760953187942505},{"id":"https://openalex.org/C205875254","wikidata":"https://www.wikidata.org/wiki/Q17156857","display_name":"Decentralised system","level":3,"score":0.4690093696117401},{"id":"https://openalex.org/C192126672","wikidata":"https://www.wikidata.org/wiki/Q1068715","display_name":"Telecommunications network","level":2,"score":0.443971186876297},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.43130651116371155},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.4286551773548126},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.4282231330871582},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3929106295108795},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.33218643069267273},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.23162305355072021},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.12203049659729004},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C77088390","wikidata":"https://www.wikidata.org/wiki/Q8513","display_name":"Database","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/smartgridcomm.2018.8587491","is_oa":false,"landing_page_url":"https://doi.org/10.1109/smartgridcomm.2018.8587491","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE International Conference on Communications, Control, and Computing Technologies for Smart Grids (SmartGridComm)","raw_type":"proceedings-article"},{"id":"pmh:oai:HAL:hal-01870771v1","is_oa":true,"landing_page_url":"https://inria.hal.science/hal-01870771","pdf_url":null,"source":{"id":"https://openalex.org/S4306402512","display_name":"HAL (Le Centre pour la Communication Scientifique Directe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1294671590","host_organization_name":"Centre National de la Recherche Scientifique","host_organization_lineage":["https://openalex.org/I1294671590"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE International Conference on Communications, Control, and Computing Technologies for Smart Grids, Oct 2018, Aalborg, Denmark","raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":{"id":"pmh:oai:HAL:hal-01870771v1","is_oa":true,"landing_page_url":"https://inria.hal.science/hal-01870771","pdf_url":null,"source":{"id":"https://openalex.org/S4306402512","display_name":"HAL (Le Centre pour la Communication Scientifique Directe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1294671590","host_organization_name":"Centre National de la Recherche Scientifique","host_organization_lineage":["https://openalex.org/I1294671590"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE International Conference on Communications, Control, and Computing Technologies for Smart Grids, Oct 2018, Aalborg, Denmark","raw_type":"info:eu-repo/semantics/conferenceObject"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.8700000047683716}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W1892079978","https://openalex.org/W1948445351","https://openalex.org/W1987992749","https://openalex.org/W1990833963","https://openalex.org/W2031524534","https://openalex.org/W2047660223","https://openalex.org/W2050298360","https://openalex.org/W2085102526","https://openalex.org/W2122379782","https://openalex.org/W2136236807","https://openalex.org/W2610279013","https://openalex.org/W2766748221","https://openalex.org/W3104452722"],"related_works":["https://openalex.org/W1574359403","https://openalex.org/W2057975886","https://openalex.org/W2355150740","https://openalex.org/W1570369983","https://openalex.org/W2906602677","https://openalex.org/W2051053503","https://openalex.org/W195896717","https://openalex.org/W3112588909","https://openalex.org/W1993958856","https://openalex.org/W2145333452"],"abstract_inverted_index":{"Microgrids":[0],"are":[1,30,132],"adopted":[2],"to":[3,50,54,112,134],"provide":[4],"distributed":[5,25,89],"generation":[6],"of":[7,14,20,70,109,125],"renewable":[8],"energy":[9],"resources":[10],"and":[11,26,58,65,76,92,106,138,143],"scalable":[12],"integration":[13],"loads.":[15],"To":[16],"ensure":[17],"the":[18,41,45,73,82,85,94,104,121,139,151],"reliability":[19],"their":[21,37,100],"power":[22],"system":[23],"operations,":[24],"cooperative":[27,74],"control":[28,38,75,123],"schemes":[29],"proposed":[31],"by":[32,99],"integrating":[33],"communication":[34,46,77,86],"networks":[35],"at":[36,44,120],"layers.":[39],"However,":[40],"information":[42],"exchanged":[43,98],"channels":[47],"is":[48],"vulnerable":[49],"malicious":[51],"attacks":[52,71],"aiming":[53],"introduce":[55],"voltage":[56,96,118,141,146],"instability":[57],"blackouts.":[59],"In":[60],"this":[61,110,136],"paper,":[62],"we":[63],"design":[64],"evaluate":[66],"a":[67,126],"novel":[68],"type":[69],"on":[72,116],"layers":[78,124],"in":[79,150],"microgrids,":[80],"where":[81],"attacker":[83],"targets":[84],"links":[87],"between":[88],"generators":[90],"(DGs)":[91],"manipulates":[93],"reference":[95,117,145],"data":[97],"controllers.":[101],"We":[102],"analyze":[103],"control-theoretic":[105],"detectability":[107],"properties":[108],"attack":[111],"assess":[113],"its":[114],"impact":[115],"synchronization":[119,147],"different":[122],"microgrid.":[127,152],"Results":[128],"from":[129],"numerical":[130],"simulation":[131],"presented":[133],"demonstrate":[135],"attack,":[137],"maximum":[140],"deviation":[142],"inaccurate":[144],"it":[148],"causes":[149]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":3},{"year":2023,"cited_by_count":1},{"year":2020,"cited_by_count":4},{"year":2019,"cited_by_count":1}],"updated_date":"2026-07-25T09:21:30.201066","created_date":"2025-10-10T00:00:00"}
