{"id":"https://openalex.org/W2782996820","doi":"https://doi.org/10.1109/smartgridcomm.2017.8340678","title":"MAS for automated black start of multi-microgrids","display_name":"MAS for automated black start of multi-microgrids","publication_year":2017,"publication_date":"2017-10-01","ids":{"openalex":"https://openalex.org/W2782996820","doi":"https://doi.org/10.1109/smartgridcomm.2017.8340678","mag":"2782996820"},"language":"en","primary_location":{"id":"doi:10.1109/smartgridcomm.2017.8340678","is_oa":false,"landing_page_url":"https://doi.org/10.1109/smartgridcomm.2017.8340678","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE International Conference on Smart Grid Communications (SmartGridComm)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5089040165","display_name":"P. McKeever","orcid":"https://orcid.org/0000-0002-1767-6950"},"institutions":[{"id":"https://openalex.org/I887968799","display_name":"RWTH Aachen University","ror":"https://ror.org/04xfq0f34","country_code":"DE","type":"education","lineage":["https://openalex.org/I887968799"]}],"countries":["DE"],"is_corresponding":true,"raw_author_name":"P. McKeever","raw_affiliation_strings":["Institute for Automation of Complex Power Systems, E.ON ERC - RWTH Aachen University, Aachen, Germany"],"affiliations":[{"raw_affiliation_string":"Institute for Automation of Complex Power Systems, E.ON ERC - RWTH Aachen University, Aachen, Germany","institution_ids":["https://openalex.org/I887968799"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5066045788","display_name":"Edoardo De Din","orcid":"https://orcid.org/0000-0003-2271-4808"},"institutions":[{"id":"https://openalex.org/I887968799","display_name":"RWTH Aachen University","ror":"https://ror.org/04xfq0f34","country_code":"DE","type":"education","lineage":["https://openalex.org/I887968799"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"E. De Din","raw_affiliation_strings":["Institute for Automation of Complex Power Systems, E.ON ERC - RWTH Aachen University, Aachen, Germany"],"affiliations":[{"raw_affiliation_string":"Institute for Automation of Complex Power Systems, E.ON ERC - RWTH Aachen University, Aachen, Germany","institution_ids":["https://openalex.org/I887968799"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5031745411","display_name":"Abhinav Sadu","orcid":null},"institutions":[{"id":"https://openalex.org/I887968799","display_name":"RWTH Aachen University","ror":"https://ror.org/04xfq0f34","country_code":"DE","type":"education","lineage":["https://openalex.org/I887968799"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"A. Sadu","raw_affiliation_strings":["Institute for Automation of Complex Power Systems, E.ON ERC - RWTH Aachen University, Aachen, Germany"],"affiliations":[{"raw_affiliation_string":"Institute for Automation of Complex Power Systems, E.ON ERC - RWTH Aachen University, Aachen, Germany","institution_ids":["https://openalex.org/I887968799"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5030410007","display_name":"Antonello Monti","orcid":"https://orcid.org/0000-0003-1914-9801"},"institutions":[{"id":"https://openalex.org/I887968799","display_name":"RWTH Aachen University","ror":"https://ror.org/04xfq0f34","country_code":"DE","type":"education","lineage":["https://openalex.org/I887968799"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"A. Monti","raw_affiliation_strings":["Institute for Automation of Complex Power Systems, E.ON ERC - RWTH Aachen University, Aachen, Germany"],"affiliations":[{"raw_affiliation_string":"Institute for Automation of Complex Power Systems, E.ON ERC - RWTH Aachen University, Aachen, Germany","institution_ids":["https://openalex.org/I887968799"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5089040165"],"corresponding_institution_ids":["https://openalex.org/I887968799"],"apc_list":null,"apc_paid":null,"fwci":0.2039,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.56974402,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"32","last_page":"37"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9979000091552734,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9850000143051147,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.990792989730835},{"id":"https://openalex.org/keywords/blackout","display_name":"Blackout","score":0.735539436340332},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.6360297203063965},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6067653894424438},{"id":"https://openalex.org/keywords/inverter","display_name":"Inverter","score":0.5925024151802063},{"id":"https://openalex.org/keywords/battery","display_name":"Battery (electricity)","score":0.4376831352710724},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.4345664978027344},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.345603346824646},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.32224494218826294},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.25371724367141724},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.22515779733657837},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.22204628586769104},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.1872616410255432},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.16074791550636292},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.07009387016296387}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.990792989730835},{"id":"https://openalex.org/C2777693866","wikidata":"https://www.wikidata.org/wiki/Q359099","display_name":"Blackout","level":4,"score":0.735539436340332},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.6360297203063965},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6067653894424438},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.5925024151802063},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.4376831352710724},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.4345664978027344},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.345603346824646},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.32224494218826294},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.25371724367141724},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.22515779733657837},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.22204628586769104},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.1872616410255432},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.16074791550636292},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.07009387016296387},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/smartgridcomm.2017.8340678","is_oa":false,"landing_page_url":"https://doi.org/10.1109/smartgridcomm.2017.8340678","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE International Conference on Smart Grid Communications (SmartGridComm)","raw_type":"proceedings-article"},{"id":"pmh:oai:publications.rwth-aachen.de:711981","is_oa":false,"landing_page_url":"https://publications.rwth-aachen.de/record/711981","pdf_url":null,"source":{"id":"https://openalex.org/S4306401033","display_name":"RWTH Publications (RWTH Aachen)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I887968799","host_organization_name":"RWTH Aachen University","host_organization_lineage":["https://openalex.org/I887968799"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Piscataway, NJ : IEEE 32-37 (2017). doi:10.1109/SmartGridComm.2017.8340678","raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.5400000214576721,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320320300","display_name":"European Commission","ror":"https://ror.org/00k4n6c32"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":24,"referenced_works":["https://openalex.org/W1489770539","https://openalex.org/W1598852905","https://openalex.org/W1980187301","https://openalex.org/W1990833963","https://openalex.org/W1994959046","https://openalex.org/W1995827237","https://openalex.org/W2042420160","https://openalex.org/W2051294245","https://openalex.org/W2066849424","https://openalex.org/W2074671922","https://openalex.org/W2117043888","https://openalex.org/W2127761430","https://openalex.org/W2129728859","https://openalex.org/W2144125455","https://openalex.org/W2151903076","https://openalex.org/W2160643434","https://openalex.org/W2206956117","https://openalex.org/W2320040257","https://openalex.org/W2343448572","https://openalex.org/W2415645061","https://openalex.org/W2511115537","https://openalex.org/W2533771995","https://openalex.org/W4232284745","https://openalex.org/W6700465429"],"related_works":["https://openalex.org/W3017475175","https://openalex.org/W2767417207","https://openalex.org/W2838475516","https://openalex.org/W2769566482","https://openalex.org/W1584345695","https://openalex.org/W2906982356","https://openalex.org/W3183483069","https://openalex.org/W2896737675","https://openalex.org/W2380188132","https://openalex.org/W2965993747","https://openalex.org/W2870309440","https://openalex.org/W2060324290","https://openalex.org/W2904843881","https://openalex.org/W2168235324","https://openalex.org/W2328130308","https://openalex.org/W2542253016","https://openalex.org/W3211945875","https://openalex.org/W2604628368","https://openalex.org/W2908824649","https://openalex.org/W1986001085"],"abstract_inverted_index":{"Current":[0],"methods":[1],"for":[2],"performing":[3],"microgrid":[4,35,72,89,104],"black":[5,36,73],"start":[6,37,74],"require":[7],"a":[8,22,29,34,39,117],"series":[9],"of":[10],"steps":[11],"to":[12,32,45,66,90],"be":[13,46,91],"performed":[14,115],"where":[15],"loads":[16],"are":[17,123],"connected":[18],"and":[19,61,82,100],"disconnected,":[20],"making":[21],"fully-automated":[23],"procedure":[24,44,75],"unfeasible.":[25],"This":[26],"paper":[27],"presents":[28],"novel":[30],"method":[31],"perform":[33],"in":[38,52,87,102,111],"single":[40],"step,":[41],"enabling":[42],"the":[43,63,68,88,94,98,103,112,128],"automatically":[47],"carried":[48],"out.":[49],"Microgrids":[50],"started":[51],"this":[53],"way":[54],"can":[55],"then":[56],"synchronise":[57],"with":[58,62,107,116,125],"each":[59],"other":[60],"HV":[64],"grid":[65,80],"expand":[67],"restored":[69],"grid.":[70],"The":[71],"is":[76,114],"prepared":[77],"during":[78,93],"normal":[79],"operation":[81],"requires":[83],"only":[84],"minimal":[85],"communication":[86],"executed":[92],"blackout,":[95],"relying":[96],"on":[97],"DERs":[99],"storages":[101],"being":[105],"equipped":[106],"battery":[108],"packs.":[109],"Co-ordination":[110],"multi-microgrid":[113],"multi-agent":[118],"system.":[119],"Inverter":[120],"control":[121],"algorithms":[122],"presented":[124],"results":[126],"verifying":[127],"concept.":[129]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1}],"updated_date":"2026-04-04T16:13:02.066488","created_date":"2025-10-10T00:00:00"}
