{"id":"https://openalex.org/W2560972841","doi":"https://doi.org/10.1109/smartgridcomm.2016.7778747","title":"Time Slotted Channel Hopping for smart metering: Measurements and analysis of medium access","display_name":"Time Slotted Channel Hopping for smart metering: Measurements and analysis of medium access","publication_year":2016,"publication_date":"2016-11-01","ids":{"openalex":"https://openalex.org/W2560972841","doi":"https://doi.org/10.1109/smartgridcomm.2016.7778747","mag":"2560972841"},"language":"en","primary_location":{"id":"doi:10.1109/smartgridcomm.2016.7778747","is_oa":false,"landing_page_url":"https://doi.org/10.1109/smartgridcomm.2016.7778747","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 IEEE International Conference on Smart Grid Communications (SmartGridComm)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"http://mediatum.ub.tum.de/node?id=1346089","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5053912544","display_name":"Mikhail Vilgelm","orcid":"https://orcid.org/0000-0001-7630-5538"},"institutions":[{"id":"https://openalex.org/I62916508","display_name":"Technical University of Munich","ror":"https://ror.org/02kkvpp62","country_code":"DE","type":"education","lineage":["https://openalex.org/I62916508"]}],"countries":["DE"],"is_corresponding":true,"raw_author_name":"Mikhail Vilgelm","raw_affiliation_strings":["Chair of Communication Networks, Technical University of Munich, Germany"],"affiliations":[{"raw_affiliation_string":"Chair of Communication Networks, Technical University of Munich, Germany","institution_ids":["https://openalex.org/I62916508"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5072121719","display_name":"H. Murat G\u00fcrsu","orcid":"https://orcid.org/0000-0003-3866-231X"},"institutions":[{"id":"https://openalex.org/I62916508","display_name":"Technical University of Munich","ror":"https://ror.org/02kkvpp62","country_code":"DE","type":"education","lineage":["https://openalex.org/I62916508"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Murat Gursu","raw_affiliation_strings":["Chair of Communication Networks, Technical University of Munich, Germany"],"affiliations":[{"raw_affiliation_string":"Chair of Communication Networks, Technical University of Munich, Germany","institution_ids":["https://openalex.org/I62916508"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5013412409","display_name":"Samuele Zoppi","orcid":"https://orcid.org/0000-0002-9987-7608"},"institutions":[{"id":"https://openalex.org/I62916508","display_name":"Technical University of Munich","ror":"https://ror.org/02kkvpp62","country_code":"DE","type":"education","lineage":["https://openalex.org/I62916508"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Samuele Zoppi","raw_affiliation_strings":["Chair of Communication Networks, Technical University of Munich, Germany"],"affiliations":[{"raw_affiliation_string":"Chair of Communication Networks, Technical University of Munich, Germany","institution_ids":["https://openalex.org/I62916508"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5021781616","display_name":"Wolfgang Kellerer","orcid":"https://orcid.org/0000-0003-4358-8038"},"institutions":[{"id":"https://openalex.org/I62916508","display_name":"Technical University of Munich","ror":"https://ror.org/02kkvpp62","country_code":"DE","type":"education","lineage":["https://openalex.org/I62916508"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Wolfgang Kellerer","raw_affiliation_strings":["Chair of Communication Networks, Technical University of Munich, Germany"],"affiliations":[{"raw_affiliation_string":"Chair of Communication Networks, Technical University of Munich, Germany","institution_ids":["https://openalex.org/I62916508"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5053912544"],"corresponding_institution_ids":["https://openalex.org/I62916508"],"apc_list":null,"apc_paid":null,"fwci":1.8747,"has_fulltext":false,"cited_by_count":10,"citation_normalized_percentile":{"value":0.87174,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":null,"issue":null,"first_page":"109","last_page":"115"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12146","display_name":"Power Line Communications and Noise","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11158","display_name":"Wireless Networks and Protocols","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7503446936607361},{"id":"https://openalex.org/keywords/automatic-meter-reading","display_name":"Automatic meter reading","score":0.7057212591171265},{"id":"https://openalex.org/keywords/testbed","display_name":"Testbed","score":0.7005494236946106},{"id":"https://openalex.org/keywords/metering-mode","display_name":"Metering mode","score":0.6870619058609009},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.6450096368789673},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.5743919610977173},{"id":"https://openalex.org/keywords/channel","display_name":"Channel (broadcasting)","score":0.5658742189407349},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.5253669023513794},{"id":"https://openalex.org/keywords/wireless-sensor-network","display_name":"Wireless sensor network","score":0.47951701283454895},{"id":"https://openalex.org/keywords/transmitter","display_name":"Transmitter","score":0.436974436044693},{"id":"https://openalex.org/keywords/smart-meter","display_name":"Smart meter","score":0.427846759557724},{"id":"https://openalex.org/keywords/interference","display_name":"Interference (communication)","score":0.4225602447986603},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.3904481530189514},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.38058987259864807},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.17930322885513306},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.16264832019805908},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.1584027111530304}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7503446936607361},{"id":"https://openalex.org/C93763578","wikidata":"https://www.wikidata.org/wiki/Q3503672","display_name":"Automatic meter reading","level":3,"score":0.7057212591171265},{"id":"https://openalex.org/C31395832","wikidata":"https://www.wikidata.org/wiki/Q1318674","display_name":"Testbed","level":2,"score":0.7005494236946106},{"id":"https://openalex.org/C30905978","wikidata":"https://www.wikidata.org/wiki/Q815598","display_name":"Metering mode","level":2,"score":0.6870619058609009},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.6450096368789673},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.5743919610977173},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.5658742189407349},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.5253669023513794},{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.47951701283454895},{"id":"https://openalex.org/C47798520","wikidata":"https://www.wikidata.org/wiki/Q190157","display_name":"Transmitter","level":3,"score":0.436974436044693},{"id":"https://openalex.org/C2779510800","wikidata":"https://www.wikidata.org/wiki/Q1630602","display_name":"Smart meter","level":3,"score":0.427846759557724},{"id":"https://openalex.org/C32022120","wikidata":"https://www.wikidata.org/wiki/Q797225","display_name":"Interference (communication)","level":3,"score":0.4225602447986603},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.3904481530189514},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.38058987259864807},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.17930322885513306},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.16264832019805908},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.1584027111530304},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/smartgridcomm.2016.7778747","is_oa":false,"landing_page_url":"https://doi.org/10.1109/smartgridcomm.2016.7778747","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 IEEE International Conference on Smart Grid Communications (SmartGridComm)","raw_type":"proceedings-article"},{"id":"pmh:oai:mediatum.ub.tum.de:node/1346089","is_oa":true,"landing_page_url":"http://mediatum.ub.tum.de/node?id=1346089","pdf_url":null,"source":{"id":"https://openalex.org/S4377196330","display_name":"mediaTUM  (Technical University of Munich)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I62916508","host_organization_name":"Technical University of Munich","host_organization_lineage":["https://openalex.org/I62916508"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"article"}],"best_oa_location":{"id":"pmh:oai:mediatum.ub.tum.de:node/1346089","is_oa":true,"landing_page_url":"http://mediatum.ub.tum.de/node?id=1346089","pdf_url":null,"source":{"id":"https://openalex.org/S4377196330","display_name":"mediaTUM  (Technical University of Munich)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I62916508","host_organization_name":"Technical University of Munich","host_organization_lineage":["https://openalex.org/I62916508"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"article"},"sustainable_development_goals":[{"score":0.8100000023841858,"display_name":"Quality Education","id":"https://metadata.un.org/sdg/4"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320322670","display_name":"Tehran University of Medical Sciences and Health Services","ror":"https://ror.org/01c4pz451"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":18,"referenced_works":["https://openalex.org/W418204025","https://openalex.org/W1591097968","https://openalex.org/W1622873960","https://openalex.org/W1979728956","https://openalex.org/W1988537848","https://openalex.org/W2000687010","https://openalex.org/W2023775398","https://openalex.org/W2042420160","https://openalex.org/W2052190282","https://openalex.org/W2081264594","https://openalex.org/W2085625270","https://openalex.org/W2122682296","https://openalex.org/W2127546670","https://openalex.org/W2136221657","https://openalex.org/W2287615672","https://openalex.org/W2486517382","https://openalex.org/W2904901051","https://openalex.org/W6656382023"],"related_works":["https://openalex.org/W2034434590","https://openalex.org/W4312869071","https://openalex.org/W2028978355","https://openalex.org/W25930971","https://openalex.org/W1518803063","https://openalex.org/W3205631650","https://openalex.org/W2775355700","https://openalex.org/W2077996342","https://openalex.org/W3018909029","https://openalex.org/W1990698919"],"abstract_inverted_index":{"The":[0],"paper":[1],"presents":[2],"an":[3],"indoor":[4],"testbed":[5],"evaluation":[6,28],"of":[7,26,34,41],"a":[8,37,49],"multi-hop":[9],"IEEE":[10,42],"802.15.4e":[11],"Time":[12],"Slotted":[13],"Channel":[14],"Hopping":[15],"(TSCH)":[16],"sensor":[17],"network,":[18],"operating":[19],"in":[20,48],"2.4":[21],"GHz":[22],"band.":[23],"First":[24],"goal":[25],"the":[27,32,55,98,115,128],"is":[29,124],"to":[30,134],"assess":[31],"perspectives":[33],"TSCH,":[35],"as":[36],"more":[38],"reliable":[39],"version":[40],"802.15.4,":[43],"for":[44,58,90,126],"meter":[45,70],"reading":[46,71],"applications":[47],"Smart":[50],"Grid.":[51],"Secondly,":[52],"we":[53,83],"compare":[54],"network":[56],"performance":[57],"two":[59,68],"medium":[60],"access":[61],"schemes:":[62],"contention-based":[63],"and":[64,77,93,102,105,131],"contention-free.":[65],"We":[66],"model":[67],"automatic":[69],"applications,":[72],"representing":[73],"regular":[74],"metering":[75],"readings":[76],"alarm":[78],"reporting.":[79],"With":[80],"this":[81],"model,":[82],"have":[84],"collected":[85],"eight":[86],"measurement":[87],"data":[88,99],"sets":[89],"different":[91],"interference":[92],"load":[94],"conditions.":[95],"Based":[96],"on":[97],"sets,":[100],"link-":[101],"end-to-end":[103,106],"reliability,":[104],"delay":[107,116],"are":[108,140],"analyzed.":[109],"Our":[110],"results":[111],"point":[112],"out":[113],"that":[114],"constraints":[117],"can":[118],"be":[119],"satisfied.":[120],"However,":[121],"channel":[122],"hopping":[123],"insufficient":[125],"meeting":[127],"reliability":[129],"requirements,":[130],"additional":[132],"mechanisms":[133],"couple":[135],"with":[136],"high":[137],"link-layer":[138],"losses":[139],"required.":[141]},"counts_by_year":[{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":2},{"year":2017,"cited_by_count":4}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
