{"id":"https://openalex.org/W2307503080","doi":"https://doi.org/10.1109/smartgridcomm.2015.7436413","title":"Smart home energy management systems based on non-intrusive load monitoring","display_name":"Smart home energy management systems based on non-intrusive load monitoring","publication_year":2015,"publication_date":"2015-11-01","ids":{"openalex":"https://openalex.org/W2307503080","doi":"https://doi.org/10.1109/smartgridcomm.2015.7436413","mag":"2307503080"},"language":"en","primary_location":{"id":"doi:10.1109/smartgridcomm.2015.7436413","is_oa":false,"landing_page_url":"https://doi.org/10.1109/smartgridcomm.2015.7436413","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE International Conference on Smart Grid Communications (SmartGridComm)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5060160424","display_name":"Wenjin Jason Li","orcid":null},"institutions":[{"id":"https://openalex.org/I200769079","display_name":"Hong Kong University of Science and Technology","ror":"https://ror.org/00q4vv597","country_code":"HK","type":"education","lineage":["https://openalex.org/I200769079"]}],"countries":["HK"],"is_corresponding":false,"raw_author_name":"Wenjin Jason Li","raw_affiliation_strings":["Department of Electronic and Computer Engineering, The Hong Kong University of Science and Technology, Hong Kong"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electronic and Computer Engineering, The Hong Kong University of Science and Technology, Hong Kong","institution_ids":["https://openalex.org/I200769079"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5047753222","display_name":"Xiaoqi Tan","orcid":"https://orcid.org/0000-0002-5339-3245"},"institutions":[{"id":"https://openalex.org/I200769079","display_name":"Hong Kong University of Science and Technology","ror":"https://ror.org/00q4vv597","country_code":"HK","type":"education","lineage":["https://openalex.org/I200769079"]}],"countries":["HK"],"is_corresponding":false,"raw_author_name":"Xiaoqi Tan","raw_affiliation_strings":["Department of Electronic and Computer Engineering, The Hong Kong University of Science and Technology, Hong Kong"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electronic and Computer Engineering, The Hong Kong University of Science and Technology, Hong Kong","institution_ids":["https://openalex.org/I200769079"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5040138091","display_name":"Danny H. K. Tsang","orcid":"https://orcid.org/0000-0003-0135-7098"},"institutions":[{"id":"https://openalex.org/I200769079","display_name":"Hong Kong University of Science and Technology","ror":"https://ror.org/00q4vv597","country_code":"HK","type":"education","lineage":["https://openalex.org/I200769079"]}],"countries":["HK"],"is_corresponding":false,"raw_author_name":"Danny H. K. Tsang","raw_affiliation_strings":["Department of Electronic and Computer Engineering, The Hong Kong University of Science and Technology, Hong Kong"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electronic and Computer Engineering, The Hong Kong University of Science and Technology, Hong Kong","institution_ids":["https://openalex.org/I200769079"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I200769079"],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":9,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"885","last_page":"890"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12238","display_name":"Green IT and Sustainability","score":0.9872000217437744,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9835000038146973,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7166554927825928},{"id":"https://openalex.org/keywords/rendering","display_name":"Rendering (computer graphics)","score":0.6553911566734314},{"id":"https://openalex.org/keywords/energy-management","display_name":"Energy management","score":0.6240431666374207},{"id":"https://openalex.org/keywords/home-automation","display_name":"Home automation","score":0.6224907040596008},{"id":"https://openalex.org/keywords/key","display_name":"Key (lock)","score":0.6149986386299133},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.5955947637557983},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.5545154809951782},{"id":"https://openalex.org/keywords/energy-conservation","display_name":"Energy conservation","score":0.5522331595420837},{"id":"https://openalex.org/keywords/energy-management-system","display_name":"Energy management system","score":0.5194432139396667},{"id":"https://openalex.org/keywords/data-collection","display_name":"Data collection","score":0.5180249810218811},{"id":"https://openalex.org/keywords/big-data","display_name":"Big data","score":0.4670362174510956},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.44606438279151917},{"id":"https://openalex.org/keywords/component","display_name":"Component (thermodynamics)","score":0.43447959423065186},{"id":"https://openalex.org/keywords/building-automation","display_name":"Building automation","score":0.4268476366996765},{"id":"https://openalex.org/keywords/building-management-system","display_name":"Building management system","score":0.4157716929912567},{"id":"https://openalex.org/keywords/risk-analysis","display_name":"Risk analysis (engineering)","score":0.3870810866355896},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.3817092180252075},{"id":"https://openalex.org/keywords/computer-security","display_name":"Computer security","score":0.36993616819381714},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.33031782507896423},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.17617979645729065},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.17420220375061035},{"id":"https://openalex.org/keywords/data-mining","display_name":"Data mining","score":0.13911768794059753},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.13110694289207458}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7166554927825928},{"id":"https://openalex.org/C205711294","wikidata":"https://www.wikidata.org/wiki/Q176953","display_name":"Rendering (computer graphics)","level":2,"score":0.6553911566734314},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.6240431666374207},{"id":"https://openalex.org/C507571656","wikidata":"https://www.wikidata.org/wiki/Q848436","display_name":"Home automation","level":2,"score":0.6224907040596008},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.6149986386299133},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.5955947637557983},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.5545154809951782},{"id":"https://openalex.org/C520301825","wikidata":"https://www.wikidata.org/wiki/Q380170","display_name":"Energy conservation","level":2,"score":0.5522331595420837},{"id":"https://openalex.org/C2781260460","wikidata":"https://www.wikidata.org/wiki/Q6139999","display_name":"Energy management system","level":4,"score":0.5194432139396667},{"id":"https://openalex.org/C133462117","wikidata":"https://www.wikidata.org/wiki/Q4929239","display_name":"Data collection","level":2,"score":0.5180249810218811},{"id":"https://openalex.org/C75684735","wikidata":"https://www.wikidata.org/wiki/Q858810","display_name":"Big data","level":2,"score":0.4670362174510956},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.44606438279151917},{"id":"https://openalex.org/C168167062","wikidata":"https://www.wikidata.org/wiki/Q1117970","display_name":"Component (thermodynamics)","level":2,"score":0.43447959423065186},{"id":"https://openalex.org/C83931994","wikidata":"https://www.wikidata.org/wiki/Q1149653","display_name":"Building automation","level":2,"score":0.4268476366996765},{"id":"https://openalex.org/C106527866","wikidata":"https://www.wikidata.org/wiki/Q1489497","display_name":"Building management system","level":3,"score":0.4157716929912567},{"id":"https://openalex.org/C112930515","wikidata":"https://www.wikidata.org/wiki/Q4389547","display_name":"Risk analysis (engineering)","level":1,"score":0.3870810866355896},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.3817092180252075},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.36993616819381714},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.33031782507896423},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.17617979645729065},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.17420220375061035},{"id":"https://openalex.org/C124101348","wikidata":"https://www.wikidata.org/wiki/Q172491","display_name":"Data mining","level":1,"score":0.13911768794059753},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.13110694289207458},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/smartgridcomm.2015.7436413","is_oa":false,"landing_page_url":"https://doi.org/10.1109/smartgridcomm.2015.7436413","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE International Conference on Smart Grid Communications (SmartGridComm)","raw_type":"proceedings-article"},{"id":"pmh:oai:repository.hkust.edu.hk:1783.1-77453","is_oa":false,"landing_page_url":"http://repository.hkust.edu.hk/ir/Record/1783.1-77453","pdf_url":null,"source":{"id":"https://openalex.org/S4306401796","display_name":"Rare & Special e-Zone (The Hong Kong University of Science and Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I200769079","host_organization_name":"Hong Kong University of Science and Technology","host_organization_lineage":["https://openalex.org/I200769079"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Conference paper"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W1575597416","https://openalex.org/W1994042232","https://openalex.org/W2013000896","https://openalex.org/W2056912578","https://openalex.org/W2062707341","https://openalex.org/W2092991234","https://openalex.org/W2097481773","https://openalex.org/W2104153904","https://openalex.org/W2107659291","https://openalex.org/W2123910460","https://openalex.org/W2222512263","https://openalex.org/W6634499289"],"related_works":["https://openalex.org/W2749199243","https://openalex.org/W4240359851","https://openalex.org/W2810662003","https://openalex.org/W2164722262","https://openalex.org/W2120479322","https://openalex.org/W1860767939","https://openalex.org/W2342211903","https://openalex.org/W2535548666","https://openalex.org/W2763368380","https://openalex.org/W3015437294"],"abstract_inverted_index":{"The":[0,110,127],"concept":[1],"of":[2,17,85,133,156],"smart":[3,65,86,111],"home":[4,87,105],"has":[5],"attracted":[6],"considerable":[7],"attention":[8],"in":[9,27,77],"recent":[10],"years,":[11],"and":[12,30,45,100,125,154,177],"energy":[13,31,88,175],"management":[14,89],"is":[15,130],"one":[16],"its":[18],"key":[19,128],"component.":[20],"This":[21],"attributes":[22],"to":[23,73,138],"the":[24,36,56,63,104,115,118,122,131,136,143,152,157,184],"growing":[25],"concern":[26],"environmental":[28],"protection":[29],"conservation,":[32],"as":[33,35],"well":[34],"demands":[37],"for":[38,145],"big":[39,185],"data":[40,123,186],"collection":[41,124],"from":[42],"utility":[43],"companies":[44],"policy":[46],"makers.":[47],"Current":[48],"solutions":[49],"often":[50],"approach":[51],"this":[52,78],"problem":[53],"by":[54,173,183],"either":[55],"centralized":[57],"non-intrusive":[58],"load":[59],"monitoring":[60,99],"(NILM)":[61],"or":[62],"decentralized":[64],"controls":[66],"but":[67,180],"seldom":[68],"both,":[69],"rendering":[70],"them":[71],"impractical":[72],"some":[74],"extent.":[75],"Therefore,":[76],"paper,":[79],"we":[80],"propose":[81],"a":[82],"novel":[83],"framework":[84],"systems":[90],"incorporating":[91],"both":[92],"approaches,":[93],"so":[94],"that":[95,161],"accurate":[96],"power":[97],"consumption":[98],"intuitive":[101],"interaction":[102],"with":[103],"appliances":[106,137],"are":[107],"simultaneously":[108],"achieved.":[109],"components":[112],"directly":[113],"control":[114],"appliances,":[116],"while":[117],"central":[119],"controller":[120],"coordinates":[121],"communication.":[126],"feature":[129],"capability":[132],"automatically":[134],"mapping":[135],"their":[139],"corresponding":[140],"sockets,":[141],"reducing":[142],"necessity":[144],"manual":[146],"initial":[147],"setup.":[148],"Numerical":[149],"simulations":[150],"prove":[151],"accuracy":[153],"efficiency":[155],"framework.":[158],"We":[159],"believe":[160],"our":[162],"systems,":[163],"if":[164],"widely":[165],"deployed,":[166],"can":[167],"benefit":[168],"not":[169],"only":[170],"individual":[171],"households":[172],"saving":[174],"bills":[176],"simplifying":[178],"life":[179],"also":[181],"society":[182],"generated.":[187]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":1},{"year":2018,"cited_by_count":3},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":1}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
