{"id":"https://openalex.org/W1973461905","doi":"https://doi.org/10.1109/smartgridcomm.2013.6687967","title":"Large population optimal demand response for thermostatically controlled inertial loads","display_name":"Large population optimal demand response for thermostatically controlled inertial loads","publication_year":2013,"publication_date":"2013-10-01","ids":{"openalex":"https://openalex.org/W1973461905","doi":"https://doi.org/10.1109/smartgridcomm.2013.6687967","mag":"1973461905"},"language":"en","primary_location":{"id":"doi:10.1109/smartgridcomm.2013.6687967","is_oa":false,"landing_page_url":"https://doi.org/10.1109/smartgridcomm.2013.6687967","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 IEEE International Conference on Smart Grid Communications (SmartGridComm)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100705959","display_name":"Gaurav Sharma","orcid":"https://orcid.org/0000-0001-9735-9519"},"institutions":[{"id":"https://openalex.org/I91045830","display_name":"Texas A&M University","ror":"https://ror.org/01f5ytq51","country_code":"US","type":"education","lineage":["https://openalex.org/I91045830"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Gaurav Sharma","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Texas A & M University","Dept. of Electr. & Comput. Eng., Texas A & M Univ., College Station, TX, , USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Texas A & M University","institution_ids":["https://openalex.org/I91045830"]},{"raw_affiliation_string":"Dept. of Electr. & Comput. Eng., Texas A & M Univ., College Station, TX, , USA","institution_ids":["https://openalex.org/I91045830"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5048219277","display_name":"Le Xie","orcid":"https://orcid.org/0000-0002-9810-948X"},"institutions":[{"id":"https://openalex.org/I91045830","display_name":"Texas A&M University","ror":"https://ror.org/01f5ytq51","country_code":"US","type":"education","lineage":["https://openalex.org/I91045830"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Le Xie","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Texas A & M University","Dept. of Electr. & Comput. Eng., Texas A & M Univ., College Station, TX, , USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Texas A & M University","institution_ids":["https://openalex.org/I91045830"]},{"raw_affiliation_string":"Dept. of Electr. & Comput. Eng., Texas A & M Univ., College Station, TX, , USA","institution_ids":["https://openalex.org/I91045830"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5107699893","display_name":"P. R. Kumar","orcid":"https://orcid.org/0000-0003-0389-5367"},"institutions":[{"id":"https://openalex.org/I91045830","display_name":"Texas A&M University","ror":"https://ror.org/01f5ytq51","country_code":"US","type":"education","lineage":["https://openalex.org/I91045830"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"P. R. Kumar","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Texas A & M University","Dept. of Electr. & Comput. Eng., Texas A & M Univ., College Station, TX, , USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Texas A & M University","institution_ids":["https://openalex.org/I91045830"]},{"raw_affiliation_string":"Dept. of Electr. & Comput. Eng., Texas A & M Univ., College Station, TX, , USA","institution_ids":["https://openalex.org/I91045830"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5100705959"],"corresponding_institution_ids":["https://openalex.org/I91045830"],"apc_list":null,"apc_paid":null,"fwci":1.4187,"has_fulltext":false,"cited_by_count":14,"citation_normalized_percentile":{"value":0.82799976,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"259","last_page":"264"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10768","display_name":"Electric Vehicles and Infrastructure","score":0.9850000143051147,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9739000201225281,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/demand-response","display_name":"Demand response","score":0.7913367748260498},{"id":"https://openalex.org/keywords/news-aggregator","display_name":"News aggregator","score":0.6921638250350952},{"id":"https://openalex.org/keywords/flexibility","display_name":"Flexibility (engineering)","score":0.647089421749115},{"id":"https://openalex.org/keywords/smoothing","display_name":"Smoothing","score":0.5951086282730103},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5620360970497131},{"id":"https://openalex.org/keywords/mathematical-optimization","display_name":"Mathematical optimization","score":0.46414247155189514},{"id":"https://openalex.org/keywords/inertia","display_name":"Inertia","score":0.4571594297885895},{"id":"https://openalex.org/keywords/population","display_name":"Population","score":0.4536019563674927},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.42300617694854736},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.4128255546092987},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.233190655708313},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.1912192404270172},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.15290376543998718},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.14241814613342285}],"concepts":[{"id":"https://openalex.org/C2779438525","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Demand response","level":3,"score":0.7913367748260498},{"id":"https://openalex.org/C180505990","wikidata":"https://www.wikidata.org/wiki/Q498267","display_name":"News aggregator","level":2,"score":0.6921638250350952},{"id":"https://openalex.org/C2780598303","wikidata":"https://www.wikidata.org/wiki/Q65921492","display_name":"Flexibility (engineering)","level":2,"score":0.647089421749115},{"id":"https://openalex.org/C3770464","wikidata":"https://www.wikidata.org/wiki/Q775963","display_name":"Smoothing","level":2,"score":0.5951086282730103},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5620360970497131},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.46414247155189514},{"id":"https://openalex.org/C110407247","wikidata":"https://www.wikidata.org/wiki/Q122508","display_name":"Inertia","level":2,"score":0.4571594297885895},{"id":"https://openalex.org/C2908647359","wikidata":"https://www.wikidata.org/wiki/Q2625603","display_name":"Population","level":2,"score":0.4536019563674927},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.42300617694854736},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.4128255546092987},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.233190655708313},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.1912192404270172},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.15290376543998718},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.14241814613342285},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C74650414","wikidata":"https://www.wikidata.org/wiki/Q11397","display_name":"Classical mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C149923435","wikidata":"https://www.wikidata.org/wiki/Q37732","display_name":"Demography","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C144024400","wikidata":"https://www.wikidata.org/wiki/Q21201","display_name":"Sociology","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/smartgridcomm.2013.6687967","is_oa":false,"landing_page_url":"https://doi.org/10.1109/smartgridcomm.2013.6687967","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 IEEE International Conference on Smart Grid Communications (SmartGridComm)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8899999856948853,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320306076","display_name":"National Science Foundation","ror":"https://ror.org/021nxhr62"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":18,"referenced_works":["https://openalex.org/W1582706191","https://openalex.org/W1836404886","https://openalex.org/W1983209131","https://openalex.org/W1984255025","https://openalex.org/W2002506366","https://openalex.org/W2009022268","https://openalex.org/W2060697189","https://openalex.org/W2071637194","https://openalex.org/W2076335823","https://openalex.org/W2081673784","https://openalex.org/W2088077079","https://openalex.org/W2089285747","https://openalex.org/W2111118312","https://openalex.org/W2144011235","https://openalex.org/W2167245050","https://openalex.org/W2167374930","https://openalex.org/W3145585884","https://openalex.org/W6635025675"],"related_works":["https://openalex.org/W2032085210","https://openalex.org/W3046697705","https://openalex.org/W4226431440","https://openalex.org/W3131627313","https://openalex.org/W3093688972","https://openalex.org/W3012323502","https://openalex.org/W2939108172","https://openalex.org/W2784220452","https://openalex.org/W4214604859","https://openalex.org/W2906194504"],"abstract_inverted_index":{"In":[0],"this":[1],"paper,":[2],"we":[3,25,58],"formulate":[4],"and":[5,40,52,106,124,132],"analyze":[6],"the":[7,33,84,102],"optimal":[8,88],"set":[9],"point":[10],"problem":[11],"of":[12,46,90,93,130],"thermostatically":[13],"controlled":[14],"loads":[15,81,95],"in":[16,37],"a":[17,63,127],"smart":[18],"microgrid":[19],"environment.":[20],"From":[21],"an":[22],"aggregator's":[23],"perspective,":[24],"show":[26,59],"that":[27,60],"flexibility":[28,76],"can":[29,96],"be":[30,41,97],"extracted":[31,78],"from":[32,79],"thermal":[34],"inertia":[35],"embedded":[36],"residential":[38],"customers":[39],"leveraged":[42],"for":[43,67,99],"maximum":[44,75],"utilization":[45],"variable":[47],"generation":[48],"such":[49],"as":[50],"wind":[51,131],"solar.":[53],"Through":[54],"rigorous":[55],"theoretical":[56],"results":[57],"there":[61],"is":[62,77,112,121],"fully":[64],"decentralized":[65],"mechanism":[66],"setting":[68,120],"individual":[69,108],"household":[70],"temperature":[71],"bounds":[72],"while":[73],"(a)":[74],"inertial":[80,94],"to":[82],"balance":[83],"stochastic":[85],"generation;":[86],"(b)":[87],"staggering":[89],"demand":[91],"responses":[92],"achieved":[98],"smoothing":[100],"out":[101],"overall":[103],"power":[104],"consumption;":[105],"(c)":[107],"customers'":[109],"comfort":[110],"zone":[111],"taken":[113],"into":[114],"account.":[115],"An":[116],"easy-to-implement":[117],"practical":[118],"control":[119],"also":[122],"introduced":[123],"tested":[125],"using":[126],"simple":[128],"model":[129],"load":[133],"distribution.":[134]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":2},{"year":2017,"cited_by_count":2},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":3}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
