{"id":"https://openalex.org/W4405491868","doi":"https://doi.org/10.1109/sensors60989.2024.10784832","title":"TFT-based Piezoelectret Sensor for Arterial Pulse Measurement","display_name":"TFT-based Piezoelectret Sensor for Arterial Pulse Measurement","publication_year":2024,"publication_date":"2024-10-20","ids":{"openalex":"https://openalex.org/W4405491868","doi":"https://doi.org/10.1109/sensors60989.2024.10784832"},"language":"en","primary_location":{"id":"doi:10.1109/sensors60989.2024.10784832","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sensors60989.2024.10784832","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 IEEE SENSORS","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100594248","display_name":"Chao Ren","orcid":null},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Chao Ren","raw_affiliation_strings":["Tsinghua University,State Key Laboratory of Precision Measurement Technology and Instruments,Department of Precision Instrument,China"],"affiliations":[{"raw_affiliation_string":"Tsinghua University,State Key Laboratory of Precision Measurement Technology and Instruments,Department of Precision Instrument,China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5035143947","display_name":"Jiani Xu","orcid":"https://orcid.org/0009-0006-9644-1354"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jiani Xu","raw_affiliation_strings":["Tsinghua University,State Key Laboratory of Precision Measurement Technology and Instruments,Department of Precision Instrument,China"],"affiliations":[{"raw_affiliation_string":"Tsinghua University,State Key Laboratory of Precision Measurement Technology and Instruments,Department of Precision Instrument,China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101481618","display_name":"Zeyuan Cao","orcid":"https://orcid.org/0000-0002-5928-4840"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zeyuan Cao","raw_affiliation_strings":["Tsinghua University,State Key Laboratory of Precision Measurement Technology and Instruments,Department of Precision Instrument,China"],"affiliations":[{"raw_affiliation_string":"Tsinghua University,State Key Laboratory of Precision Measurement Technology and Instruments,Department of Precision Instrument,China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5032843597","display_name":"Junchi Teng","orcid":"https://orcid.org/0009-0008-7646-5417"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Junchi Teng","raw_affiliation_strings":["Tsinghua University,State Key Laboratory of Precision Measurement Technology and Instruments,Department of Precision Instrument,China"],"affiliations":[{"raw_affiliation_string":"Tsinghua University,State Key Laboratory of Precision Measurement Technology and Instruments,Department of Precision Instrument,China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5057069064","display_name":"Xiongying Ye","orcid":"https://orcid.org/0000-0003-1752-3003"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xiongying Ye","raw_affiliation_strings":["Tsinghua University,State Key Laboratory of Precision Measurement Technology and Instruments,Department of Precision Instrument,China"],"affiliations":[{"raw_affiliation_string":"Tsinghua University,State Key Laboratory of Precision Measurement Technology and Instruments,Department of Precision Instrument,China","institution_ids":["https://openalex.org/I99065089"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5100594248"],"corresponding_institution_ids":["https://openalex.org/I99065089"],"apc_list":null,"apc_paid":null,"fwci":0.1955,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.51334854,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9686999917030334,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9686999917030334,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10205","display_name":"Advanced Fiber Optic Sensors","score":0.9287999868392944,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/pulse","display_name":"Pulse (music)","score":0.5154734253883362},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.38065305352211},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.37404799461364746},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.35952073335647583},{"id":"https://openalex.org/keywords/optoelectronics","display_name":"Optoelectronics","score":0.3536258935928345},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.21225851774215698},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.06505146622657776}],"concepts":[{"id":"https://openalex.org/C2780167933","wikidata":"https://www.wikidata.org/wiki/Q1550652","display_name":"Pulse (music)","level":3,"score":0.5154734253883362},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.38065305352211},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.37404799461364746},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.35952073335647583},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.3536258935928345},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.21225851774215698},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.06505146622657776}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/sensors60989.2024.10784832","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sensors60989.2024.10784832","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 IEEE SENSORS","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.5899999737739563}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":20,"referenced_works":["https://openalex.org/W1685840938","https://openalex.org/W1982276321","https://openalex.org/W1997900542","https://openalex.org/W2003598051","https://openalex.org/W2052351374","https://openalex.org/W2066806498","https://openalex.org/W2339545839","https://openalex.org/W2804902502","https://openalex.org/W2887381063","https://openalex.org/W2966419775","https://openalex.org/W3006031039","https://openalex.org/W3040898750","https://openalex.org/W3110317696","https://openalex.org/W4200371900","https://openalex.org/W4220786439","https://openalex.org/W4220980370","https://openalex.org/W4327683694","https://openalex.org/W4360814289","https://openalex.org/W4388302937","https://openalex.org/W4396811330"],"related_works":["https://openalex.org/W4391375266","https://openalex.org/W2899084033","https://openalex.org/W2748952813","https://openalex.org/W4404995717","https://openalex.org/W2016187641","https://openalex.org/W4404725684","https://openalex.org/W2805339068","https://openalex.org/W4246450666","https://openalex.org/W4388998267","https://openalex.org/W2898370298"],"abstract_inverted_index":{"Mechano-sensors":[0],"with":[1,44,62],"the":[2,46,50,57,90],"capability":[3,71],"of":[4,49,65,72],"monitoring":[5,13],"real-time":[6],"physiological":[7],"signals":[8],"are":[9,37],"essential":[10],"in":[11],"health":[12],"and":[14,41,70,88],"medical":[15],"diagnosis":[16],"systems.":[17],"Herein,":[18],"a":[19],"piezoelectret":[20,51,79],"sensor":[21,35,52,58,80],"based":[22],"on":[23,97],"thin":[24],"film":[25],"transistors":[26],"(TFTs)":[27],"is":[28],"reported":[29],"for":[30,84],"arterial":[31,85],"pulse":[32,86,91],"measurement.":[33],"The":[34,76],"properties":[36],"studied":[38],"through":[39],"simulation":[40],"experiment.":[42],"Integrated":[43],"TFT,":[45],"output":[47],"impedance":[48],"was":[53],"tremendously":[54],"reduced,":[55],"making":[56],"have":[59],"better":[60],"performance":[61],"higher":[63],"sensitivity":[64],"55.3":[66],"<tex":[67],"xmlns:mml=\"http://www.w3.org/1998/Math/MathML\"":[68],"xmlns:xlink=\"http://www.w3.org/1999/xlink\">$\\text{kPa}^{-1}$</tex>,":[69],"detecting":[73],"quasi-static":[74],"forces.":[75],"developed":[77],"TFT-based":[78],"can":[81],"be":[82],"used":[83],"measurement,":[87],"capture":[89],"wave":[92],"features,":[93],"providing":[94],"clinical":[95],"information":[96],"cardiovascular":[98],"dynamics.":[99]},"counts_by_year":[{"year":2025,"cited_by_count":1}],"updated_date":"2025-12-27T23:08:20.325037","created_date":"2025-10-10T00:00:00"}
