{"id":"https://openalex.org/W4405491620","doi":"https://doi.org/10.1109/sensors60989.2024.10784800","title":"Channel Assessment for a Sensor System for Status Detection of Miniature Circuit Breakers","display_name":"Channel Assessment for a Sensor System for Status Detection of Miniature Circuit Breakers","publication_year":2024,"publication_date":"2024-10-20","ids":{"openalex":"https://openalex.org/W4405491620","doi":"https://doi.org/10.1109/sensors60989.2024.10784800"},"language":"en","primary_location":{"id":"doi:10.1109/sensors60989.2024.10784800","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sensors60989.2024.10784800","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 IEEE SENSORS","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5090431978","display_name":"Andreas Port","orcid":"https://orcid.org/0000-0002-8178-1456"},"institutions":[{"id":"https://openalex.org/I885143765","display_name":"ABB (Switzerland)","ror":"https://ror.org/00ks5vt51","country_code":"CH","type":"company","lineage":["https://openalex.org/I885143765"]}],"countries":["CH"],"is_corresponding":false,"raw_author_name":"Andreas Port","raw_affiliation_strings":["ABB Corporate Research, ABB Switzerland Ltd,Baden-D&#x00E4;ttwil,Switzerland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ABB Corporate Research, ABB Switzerland Ltd,Baden-D&#x00E4;ttwil,Switzerland","institution_ids":["https://openalex.org/I885143765"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5078771078","display_name":"David Salido-Monz\u00fa","orcid":"https://orcid.org/0000-0003-4274-6874"},"institutions":[{"id":"https://openalex.org/I885143765","display_name":"ABB (Switzerland)","ror":"https://ror.org/00ks5vt51","country_code":"CH","type":"company","lineage":["https://openalex.org/I885143765"]}],"countries":["CH"],"is_corresponding":false,"raw_author_name":"David Salido-Monz\u00fa","raw_affiliation_strings":["ABB Corporate Research, ABB Switzerland Ltd,Baden-D&#x00E4;ttwil,Switzerland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ABB Corporate Research, ABB Switzerland Ltd,Baden-D&#x00E4;ttwil,Switzerland","institution_ids":["https://openalex.org/I885143765"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I885143765"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.26768963,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9944999814033508,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9944999814033508,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12451","display_name":"Smart Grid and Power Systems","score":0.978600025177002,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.9717000126838684,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/circuit-breaker","display_name":"Circuit breaker","score":0.7518128156661987},{"id":"https://openalex.org/keywords/channel","display_name":"Channel (broadcasting)","score":0.5521138310432434},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.47665077447891235},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3934467136859894},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3606533110141754},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3092917799949646}],"concepts":[{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.7518128156661987},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.5521138310432434},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.47665077447891235},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3934467136859894},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3606533110141754},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3092917799949646}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/sensors60989.2024.10784800","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sensors60989.2024.10784800","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 IEEE SENSORS","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.550000011920929,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W1977706878","https://openalex.org/W2060177410","https://openalex.org/W2091141209","https://openalex.org/W2119014417","https://openalex.org/W2122200240","https://openalex.org/W2124346308","https://openalex.org/W2125854647","https://openalex.org/W2131249468","https://openalex.org/W2141093149","https://openalex.org/W2151255203","https://openalex.org/W2161961196","https://openalex.org/W2166246763","https://openalex.org/W2166369278","https://openalex.org/W4388567283"],"related_works":["https://openalex.org/W2748952813","https://openalex.org/W2186957643","https://openalex.org/W4313289174","https://openalex.org/W2169296235","https://openalex.org/W2383147444","https://openalex.org/W2772771794","https://openalex.org/W2370462073","https://openalex.org/W2351129194","https://openalex.org/W2369017828","https://openalex.org/W2361809848"],"abstract_inverted_index":{"Status":[0],"detection":[1,21,65],"of":[2,51,73,82,126],"miniature":[3],"circuit":[4],"breakers":[5],"(MCBs)":[6],"commonly":[7],"requires":[8],"side-coupled":[9],"accessories":[10],"using":[11,22],"up":[12],"valuable":[13],"cabinet":[14],"space.":[15],"In":[16,46],"space-restricted":[17],"environments,":[18],"breaker":[19],"status":[20,64],"an":[23,62],"AC":[24],"test":[25],"signal":[26,44,94,129],"could":[27],"be":[28,41,104,132],"a":[29,58,70],"promising":[30],"alternative,":[31],"but":[32],"the":[33,49,54,80,123],"highly":[34],"varying":[35],"electrical":[36,55,119],"network":[37,56],"would":[38],"need":[39],"to":[40,106],"used":[42],"for":[43,61,99,118],"transmission.":[45],"this":[47],"study,":[48],"feasibility":[50],"relying":[52],"on":[53],"as":[57],"transmission":[59],"channel":[60],"MCB":[63],"system":[66],"is":[67],"assessed":[68],"across":[69],"frequency":[71],"range":[72],"0.1-100":[74],"MHz.":[75],"Using":[76],"simulations":[77],"and":[78,88,110],"measurements,":[79],"effects":[81],"different":[83],"cable":[84,86,101,108,115],"lengths,":[85],"topologies":[87],"loads":[89],"are":[90,96],"investigated.":[91],"Broad-and":[92],"narrowband":[93],"attenuations":[95,130],"observed,":[97],"which":[98],"simple":[100],"setups":[102],"can":[103],"attributed":[105],"individual":[107],"lengths":[109],"loads.":[111],"For":[112],"more":[113],"complex":[114],"topologies,":[116],"typical":[117],"installations":[120],"in":[121],"practice,":[122],"spectral":[124],"location":[125],"these":[127],"problematic":[128],"cannot":[131],"predicted.":[133]},"counts_by_year":[],"updated_date":"2026-06-26T08:34:08.712188","created_date":"2025-10-10T00:00:00"}