{"id":"https://openalex.org/W4389077587","doi":"https://doi.org/10.1109/sensors56945.2023.10324917","title":"Performance of a Multiparametric Water Quality Sensor in a Small-Scale Water Distribution Network","display_name":"Performance of a Multiparametric Water Quality Sensor in a Small-Scale Water Distribution Network","publication_year":2023,"publication_date":"2023-10-29","ids":{"openalex":"https://openalex.org/W4389077587","doi":"https://doi.org/10.1109/sensors56945.2023.10324917"},"language":"en","primary_location":{"id":"doi:10.1109/sensors56945.2023.10324917","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sensors56945.2023.10324917","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE SENSORS","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://univ-eiffel.hal.science/hal-04433257/document","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5061934618","display_name":"Balakumara Vignesh Muppidathi","orcid":"https://orcid.org/0000-0002-9421-969X"},"institutions":[{"id":"https://openalex.org/I1317621060","display_name":"Indian Institute of Technology Guwahati","ror":"https://ror.org/0022nd079","country_code":"IN","type":"education","lineage":["https://openalex.org/I1317621060"]},{"id":"https://openalex.org/I4210154111","display_name":"Universit\u00e9 Gustave Eiffel","ror":"https://ror.org/03x42jk29","country_code":"FR","type":"education","lineage":["https://openalex.org/I4210154111"]}],"countries":["FR","IN"],"is_corresponding":true,"raw_author_name":"Balakumara Vignesh Muppidathi","raw_affiliation_strings":["Universite Gustave Eiffel,COSYS, IMSE,France","IIT Guwahati - Indian Institute of Technology Guwahati (Guwahati 781039 Assam, India - India)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universite Gustave Eiffel,COSYS, IMSE,France","institution_ids":["https://openalex.org/I4210154111"]},{"raw_affiliation_string":"IIT Guwahati - Indian Institute of Technology Guwahati (Guwahati 781039 Assam, India - India)","institution_ids":["https://openalex.org/I1317621060"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5111955566","display_name":"St\u00e9phane Laporte","orcid":null},"institutions":[{"id":"https://openalex.org/I4210154111","display_name":"Universit\u00e9 Gustave Eiffel","ror":"https://ror.org/03x42jk29","country_code":"FR","type":"education","lineage":["https://openalex.org/I4210154111"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Stephane Laporte","raw_affiliation_strings":["Universite Gustave Eiffel,COSYS, IMSE,France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universite Gustave Eiffel,COSYS, IMSE,France","institution_ids":["https://openalex.org/I4210154111"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5025098352","display_name":"Yan Ulanowski","orcid":null},"institutions":[{"id":"https://openalex.org/I4210154111","display_name":"Universit\u00e9 Gustave Eiffel","ror":"https://ror.org/03x42jk29","country_code":"FR","type":"education","lineage":["https://openalex.org/I4210154111"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Yan Ulanowski","raw_affiliation_strings":["Universite Gustave Eiffel,COSYS, IMSE,France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universite Gustave Eiffel,COSYS, IMSE,France","institution_ids":["https://openalex.org/I4210154111"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5027892188","display_name":"Senthilmurugan Subbiah","orcid":"https://orcid.org/0000-0001-8439-3515"},"institutions":[{"id":"https://openalex.org/I1317621060","display_name":"Indian Institute of Technology Guwahati","ror":"https://ror.org/0022nd079","country_code":"IN","type":"education","lineage":["https://openalex.org/I1317621060"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Senthilmurugan Subbiah","raw_affiliation_strings":["Indian Institute of Technology,Department of Chemical Engineering,Guwahati,India","IIT Guwahati - Indian Institute of Technology Guwahati (Guwahati 781039 Assam, India - India)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Indian Institute of Technology,Department of Chemical Engineering,Guwahati,India","institution_ids":["https://openalex.org/I1317621060"]},{"raw_affiliation_string":"IIT Guwahati - Indian Institute of Technology Guwahati (Guwahati 781039 Assam, India - India)","institution_ids":["https://openalex.org/I1317621060"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5051233113","display_name":"B\u00e9reng\u008f\u00e8re Lebental","orcid":"https://orcid.org/0000-0001-8985-8203"},"institutions":[{"id":"https://openalex.org/I4210154111","display_name":"Universit\u00e9 Gustave Eiffel","ror":"https://ror.org/03x42jk29","country_code":"FR","type":"education","lineage":["https://openalex.org/I4210154111"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Berengere Lebental","raw_affiliation_strings":["Universite Gustave Eiffel,COSYS, IMSE,France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universite Gustave Eiffel,COSYS, IMSE,France","institution_ids":["https://openalex.org/I4210154111"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5061934618"],"corresponding_institution_ids":["https://openalex.org/I1317621060","https://openalex.org/I4210154111"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":{"value":0.15036803,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12697","display_name":"Water Quality Monitoring Technologies","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2312","display_name":"Water Science and Technology"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12697","display_name":"Water Quality Monitoring Technologies","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2312","display_name":"Water Science and Technology"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11472","display_name":"Analytical Chemistry and Sensors","score":0.9977999925613403,"subfield":{"id":"https://openalex.org/subfields/1502","display_name":"Bioengineering"},"field":{"id":"https://openalex.org/fields/15","display_name":"Chemical Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14249","display_name":"Water Quality Monitoring and Analysis","score":0.9860000014305115,"subfield":{"id":"https://openalex.org/subfields/2311","display_name":"Industrial and Manufacturing Engineering"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/conductivity","display_name":"Conductivity","score":0.5398733615875244},{"id":"https://openalex.org/keywords/wireless-sensor-network","display_name":"Wireless sensor network","score":0.4467697739601135},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.4438306391239166},{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.4271334707736969},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4251402020454407},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.3845839202404022},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.37827068567276},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.3346552848815918},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.32424938678741455},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.3111063241958618},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.16906774044036865},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.13111039996147156},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.09208598732948303}],"concepts":[{"id":"https://openalex.org/C131540310","wikidata":"https://www.wikidata.org/wiki/Q907564","display_name":"Conductivity","level":2,"score":0.5398733615875244},{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.4467697739601135},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.4438306391239166},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.4271334707736969},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4251402020454407},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.3845839202404022},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.37827068567276},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.3346552848815918},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.32424938678741455},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3111063241958618},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.16906774044036865},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.13111039996147156},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.09208598732948303},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/sensors56945.2023.10324917","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sensors56945.2023.10324917","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE SENSORS","raw_type":"proceedings-article"},{"id":"pmh:oai:HAL:hal-04433257v1","is_oa":true,"landing_page_url":"https://univ-eiffel.hal.science/hal-04433257","pdf_url":"https://univ-eiffel.hal.science/hal-04433257/document","source":{"id":"https://openalex.org/S4306402512","display_name":"HAL (Le Centre pour la Communication Scientifique Directe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1294671590","host_organization_name":"Centre National de la Recherche Scientifique","host_organization_lineage":["https://openalex.org/I1294671590"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"2023 IEEE SENSORS, Oct 2023, Vienne, Austria. pp.1-4, &#x27E8;10.1109/SENSORS56945.2023.10324917&#x27E9;","raw_type":"Conference papers"}],"best_oa_location":{"id":"pmh:oai:HAL:hal-04433257v1","is_oa":true,"landing_page_url":"https://univ-eiffel.hal.science/hal-04433257","pdf_url":"https://univ-eiffel.hal.science/hal-04433257/document","source":{"id":"https://openalex.org/S4306402512","display_name":"HAL (Le Centre pour la Communication Scientifique Directe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1294671590","host_organization_name":"Centre National de la Recherche Scientifique","host_organization_lineage":["https://openalex.org/I1294671590"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"2023 IEEE SENSORS, Oct 2023, Vienne, Austria. pp.1-4, &#x27E8;10.1109/SENSORS56945.2023.10324917&#x27E9;","raw_type":"Conference papers"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/6","score":0.6499999761581421,"display_name":"Clean water and sanitation"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320320300","display_name":"European Commission","ror":"https://ror.org/00k4n6c32"}],"has_content":{"pdf":true,"grobid_xml":false},"content_urls":{"pdf":"https://content.openalex.org/works/W4389077587.pdf"},"referenced_works_count":6,"referenced_works":["https://openalex.org/W1509165159","https://openalex.org/W2801638617","https://openalex.org/W3036024467","https://openalex.org/W4212781379","https://openalex.org/W4312710736","https://openalex.org/W4319998047"],"related_works":["https://openalex.org/W1975451135","https://openalex.org/W2989915292","https://openalex.org/W2378757965","https://openalex.org/W4224903346","https://openalex.org/W1544970605","https://openalex.org/W2890570089","https://openalex.org/W2073793005","https://openalex.org/W1593262897","https://openalex.org/W2372869593","https://openalex.org/W3148968234"],"abstract_inverted_index":{"Ensuring":[0],"access":[1],"to":[2,112,137,211,234],"good":[3],"quality":[4,26],"water":[5,25,124,159,205],"is":[6,37],"crucial":[7],"for":[8,23,45],"sustainable":[9],"development,":[10],"particularly":[11,156],"in":[12,54,71,96,121,153,203,224],"developing":[13],"nations.":[14],"However,":[15],"the":[16,32,139,144,154,215,219,228,232],"lack":[17],"of":[18,48,87,130,134,221],"affordable":[19],"and":[20,40,52,68,79,132,173,180,199],"reliable":[21],"solutions":[22],"monitoring":[24,47],"remains":[27],"a":[28,38,61,80,109,122,127,161],"significant":[29],"challenge":[30],"that":[31],"LOTUS":[33,117],"sensor":[34,43,85],"meets:":[35],"it":[36],"compact":[39],"versatile":[41],"multiparametric":[42],"designed":[44],"real-time":[46],"chlorine,":[49,179],"pH,":[50],"temperature,":[51,177],"conductivity":[53,77],"potable":[55],"water.":[56],"The":[57,93],"proposed":[58],"solution":[59],"features":[60],"cylinder-like":[62],"structure,":[63],"measuring":[64],"21":[65],"cm":[66,70],"long":[67],"3.5":[69],"diameter.":[72],"It":[73],"integrates":[74],"temperature":[75],"sensors,":[76,78],"<tex":[81,193,235],"xmlns:mml=\"http://www.w3.org/1998/Math/MathML\"":[82,194,236],"xmlns:xlink=\"http://www.w3.org/1999/xlink\">$2":[83],"\\mathrm{x}10$</tex>":[84],"array":[86],"multi-walled":[88],"carbon":[89],"nanotube":[90],"(CNT)":[91],"chemistors.":[92],"CNTs,":[94],"arranged":[95],"random":[97],"networks":[98],"between":[99],"interdigitated":[100],"electrodes,":[101],"can":[102],"remain":[103],"non-functionalized":[104],"or":[105],"be":[106],"functionalized":[107],"with":[108,185,227],"dedicated":[110],"polymer":[111,230],"modulate":[113],"their":[114],"sensitivity.":[115],"Six":[116],"sensors":[118,209],"were":[119,183],"tested":[120],"44m-long":[123],"loop":[125],"under":[126,157],"flow":[128],"rate":[129],"0.3m/s":[131],"pressure":[133],"1":[135],"bar":[136],"evaluate":[138],"system":[140],"performance.":[141],"To":[142],"manage":[143],"high":[145],"noise":[146],"levels":[147],"caused":[148],"by":[149,238],"strong":[150,162],"electromagnetic":[151],"interferences":[152],"facility,":[155],"flowing":[158,204],"conditions,":[160],"effort":[163],"was":[164],"put":[165],"into":[166],"data":[167],"denoising":[168,172],"techniques.":[169],"After":[170],"extensive":[171],"calibration":[174],"model":[175],"optimization,":[176],"conductivity,":[178],"pH":[181,201],"estimation":[182],"achieved":[184],"mean":[186],"absolute":[187],"error":[188],"(MAE)":[189],"as":[190,192],"low":[191],"xmlns:xlink=\"http://www.w3.org/1999/xlink\">$0.34^{\\mathrm{o}}\\mathrm{C},":[195],"73.2\\mu":[196],"\\mathrm{S}/\\text{cm},":[197],"0.13\\text{mg}/\\mathrm{L}$</tex>":[198],"0.12":[200],"unit":[202],"(achieved":[206],"on":[207],"different":[208],"due":[210],"dataset":[212,216],"limitations).":[213],"Notably,":[214],"also":[217],"demonstrates":[218],"role":[220],"CNT":[222],"functionalization":[223],"chemical":[225],"sensing,":[226],"selected":[229],"modulating":[231],"sensitivity":[233],"xmlns:xlink=\"http://www.w3.org/1999/xlink\">$\\text{pH}$</tex>":[237],"50%.":[239]},"counts_by_year":[],"updated_date":"2026-05-07T13:39:58.223016","created_date":"2025-10-10T00:00:00"}
