{"id":"https://openalex.org/W4311412448","doi":"https://doi.org/10.1109/sensors52175.2022.9967226","title":"An RFID-Based Sensor for Vascular Flow Monitoring","display_name":"An RFID-Based Sensor for Vascular Flow Monitoring","publication_year":2022,"publication_date":"2022-10-30","ids":{"openalex":"https://openalex.org/W4311412448","doi":"https://doi.org/10.1109/sensors52175.2022.9967226"},"language":"en","primary_location":{"id":"doi:10.1109/sensors52175.2022.9967226","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sensors52175.2022.9967226","pdf_url":null,"source":{"id":"https://openalex.org/S4363604906","display_name":"2022 IEEE Sensors","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 IEEE Sensors","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5070914008","display_name":"Yaneev Hacohen","orcid":"https://orcid.org/0009-0003-9335-7542"},"institutions":[{"id":"https://openalex.org/I58956616","display_name":"Case Western Reserve University","ror":"https://ror.org/051fd9666","country_code":"US","type":"education","lineage":["https://openalex.org/I58956616"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Yaneev Hacohen","raw_affiliation_strings":["Case Western Reserve University,Dept. of Electrical, Computer and System Engineering,Cleveland,USA","Dept. of Electrical, Computer and System Engineering, Case Western Reserve University, Cleveland, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Case Western Reserve University,Dept. of Electrical, Computer and System Engineering,Cleveland,USA","institution_ids":["https://openalex.org/I58956616"]},{"raw_affiliation_string":"Dept. of Electrical, Computer and System Engineering, Case Western Reserve University, Cleveland, USA","institution_ids":["https://openalex.org/I58956616"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5023937518","display_name":"Steve J. A. Majerus","orcid":"https://orcid.org/0000-0002-5057-0189"},"institutions":[{"id":"https://openalex.org/I58956616","display_name":"Case Western Reserve University","ror":"https://ror.org/051fd9666","country_code":"US","type":"education","lineage":["https://openalex.org/I58956616"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Steve Majerus","raw_affiliation_strings":["Case Western Reserve University,Dept. of Electrical, Computer and System Engineering,Cleveland,USA","Dept. of Electrical, Computer and System Engineering, Case Western Reserve University, Cleveland, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Case Western Reserve University,Dept. of Electrical, Computer and System Engineering,Cleveland,USA","institution_ids":["https://openalex.org/I58956616"]},{"raw_affiliation_string":"Dept. of Electrical, Computer and System Engineering, Case Western Reserve University, Cleveland, USA","institution_ids":["https://openalex.org/I58956616"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I58956616"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.23035393,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"48","issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10338","display_name":"Advanced Sensor and Energy Harvesting Materials","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10338","display_name":"Advanced Sensor and Energy Harvesting Materials","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11249","display_name":"Wireless Power Transfer Systems","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11932","display_name":"Wireless Body Area Networks","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/polydimethylsiloxane","display_name":"Polydimethylsiloxane","score":0.6799260973930359},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.6561833620071411},{"id":"https://openalex.org/keywords/blood-flow","display_name":"Blood flow","score":0.5775253772735596},{"id":"https://openalex.org/keywords/imaging-phantom","display_name":"Imaging phantom","score":0.5242974162101746},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.49665218591690063},{"id":"https://openalex.org/keywords/antenna","display_name":"Antenna (radio)","score":0.4324692189693451},{"id":"https://openalex.org/keywords/optoelectronics","display_name":"Optoelectronics","score":0.3291636109352112},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.25615960359573364},{"id":"https://openalex.org/keywords/nanotechnology","display_name":"Nanotechnology","score":0.13306266069412231},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.12265962362289429},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.11585986614227295},{"id":"https://openalex.org/keywords/nuclear-medicine","display_name":"Nuclear medicine","score":0.07485288381576538}],"concepts":[{"id":"https://openalex.org/C2779849746","wikidata":"https://www.wikidata.org/wiki/Q411955","display_name":"Polydimethylsiloxane","level":2,"score":0.6799260973930359},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.6561833620071411},{"id":"https://openalex.org/C158846371","wikidata":"https://www.wikidata.org/wiki/Q1642137","display_name":"Blood flow","level":2,"score":0.5775253772735596},{"id":"https://openalex.org/C104293457","wikidata":"https://www.wikidata.org/wiki/Q28324852","display_name":"Imaging phantom","level":2,"score":0.5242974162101746},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.49665218591690063},{"id":"https://openalex.org/C21822782","wikidata":"https://www.wikidata.org/wiki/Q131214","display_name":"Antenna (radio)","level":2,"score":0.4324692189693451},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.3291636109352112},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.25615960359573364},{"id":"https://openalex.org/C171250308","wikidata":"https://www.wikidata.org/wiki/Q11468","display_name":"Nanotechnology","level":1,"score":0.13306266069412231},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.12265962362289429},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.11585986614227295},{"id":"https://openalex.org/C2989005","wikidata":"https://www.wikidata.org/wiki/Q214963","display_name":"Nuclear medicine","level":1,"score":0.07485288381576538},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/sensors52175.2022.9967226","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sensors52175.2022.9967226","pdf_url":null,"source":{"id":"https://openalex.org/S4363604906","display_name":"2022 IEEE Sensors","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 IEEE Sensors","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W1988362829","https://openalex.org/W2001822903","https://openalex.org/W2059138360","https://openalex.org/W2143546470","https://openalex.org/W2167469160","https://openalex.org/W2513363793","https://openalex.org/W2907538915","https://openalex.org/W2978783097","https://openalex.org/W2979854938","https://openalex.org/W3000709619","https://openalex.org/W3009980416"],"related_works":["https://openalex.org/W1985565313","https://openalex.org/W2259450050","https://openalex.org/W2751709156","https://openalex.org/W2750029803","https://openalex.org/W2170016567","https://openalex.org/W2969481005","https://openalex.org/W2111365092","https://openalex.org/W205179978","https://openalex.org/W1968770722","https://openalex.org/W2061676111"],"abstract_inverted_index":{"This":[0,11],"work":[1],"demonstrates":[2],"a":[3,38,48,55,69,100,147],"batteryless,":[4],"implantable":[5,130],"blood-flow":[6],"sensor":[7,13,29,64,90],"with":[8,99,113,150,163],"RFID":[9,32,87],"readout.":[10],"flexible":[12,62],"system":[14],"was":[15,35,66],"developed":[16,67,134],"specifically":[17],"for":[18],"surgical":[19,45],"implantation":[20],"around":[21,47,137],"blood":[22,26,59,83,154],"vessels,":[23],"without":[24],"contacting":[25],"to":[27,43,92,135,141,166],"improve":[28],"stability.":[30],"An":[31],"data/power":[33],"antenna":[34,41],"implemented":[36],"using":[37],"split-double":[39],"helix":[40],"(DHA)":[42],"enable":[44],"placement":[46],"tubular":[49],"structure":[50],"in":[51,96],"the":[52,164],"body,":[53],"e.g.":[54],"natural":[56],"or":[57],"synthetic":[58],"vessel.":[60],"A":[61,85],"pulsation":[63],"(FPS)":[65],"from":[68,158],"piezoresistive":[70],"carbon":[71],"black-polydimethylsiloxane":[72],"(PDMS)":[73],"nanocomposite,":[74],"which":[75],"enabled":[76,89],"measurement":[77],"of":[78,103,109,115,125,139],"vascular":[79,148],"distension":[80],"caused":[81],"by":[82],"flow.":[84],"commercial":[86],"chip":[88],"readout":[91],"an":[93],"external":[94],"transceiver":[95],"real":[97],"time":[98],"sample":[101],"rate":[102,156],"12":[104],"Hz":[105],"and":[106,120],"reading":[107],"distance":[108],"3.5":[110],"cm.":[111],"DHAs":[112],"diameter":[114],"3\u20138":[116],"mm":[117],"were":[118,133],"fabricated":[119],"had":[121],"modest":[122],"quality":[123],"factors":[124],"9":[126],"-":[127,160],"23.":[128],"Prototype":[129],"DHA":[131],"antennas":[132],"wrap":[136],"vessels":[138],"3":[140],"8":[142],"mm.":[143],"Validation":[144],"experiments":[145],"on":[146],"phantom":[149],"simulated":[151],"stenosis":[152],"demonstrated":[153],"flow":[155,168],"monitoring":[157],"200":[159],"400":[161],"mL/min":[162],"capacity":[165],"distinguish":[167],"changes":[169],"as":[170,172],"low":[171],"10":[173],"mL/min.":[174]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
