{"id":"https://openalex.org/W3110919433","doi":"https://doi.org/10.1109/sensors47125.2020.9278762","title":"Portable Gait Lab: Instantaneous centre of mass velocity using three inertial measurement units","display_name":"Portable Gait Lab: Instantaneous centre of mass velocity using three inertial measurement units","publication_year":2020,"publication_date":"2020-10-25","ids":{"openalex":"https://openalex.org/W3110919433","doi":"https://doi.org/10.1109/sensors47125.2020.9278762","mag":"3110919433"},"language":"en","primary_location":{"id":"doi:10.1109/sensors47125.2020.9278762","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sensors47125.2020.9278762","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 IEEE SENSORS","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://research.utwente.nl/en/publications/1609a88d-e725-4e04-979f-defa191766a2","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5102748727","display_name":"Mohamed Irfan Mohamed Refai","orcid":"https://orcid.org/0000-0002-3617-5131"},"institutions":[{"id":"https://openalex.org/I94624287","display_name":"University of Twente","ror":"https://ror.org/006hf6230","country_code":"NL","type":"education","lineage":["https://openalex.org/I94624287"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Mohamed Irfan Mohamed Refai","raw_affiliation_strings":["Biomedical Signals and Systems, University of Twente, NL"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Biomedical Signals and Systems, University of Twente, NL","institution_ids":["https://openalex.org/I94624287"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5067633889","display_name":"Bert-Jan van Beijnum","orcid":"https://orcid.org/0000-0002-9673-752X"},"institutions":[{"id":"https://openalex.org/I94624287","display_name":"University of Twente","ror":"https://ror.org/006hf6230","country_code":"NL","type":"education","lineage":["https://openalex.org/I94624287"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Bert-Jan F. van Beijnum","raw_affiliation_strings":["Biomedical Signals and Systems, University of Twente, NL"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Biomedical Signals and Systems, University of Twente, NL","institution_ids":["https://openalex.org/I94624287"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5075956492","display_name":"Jaap H. Buurke","orcid":"https://orcid.org/0000-0003-4323-1047"},"institutions":[{"id":"https://openalex.org/I4210104520","display_name":"Roessingh Research and Development","ror":"https://ror.org/01dmjt679","country_code":"NL","type":"nonprofit","lineage":["https://openalex.org/I4210104520"]},{"id":"https://openalex.org/I94624287","display_name":"University of Twente","ror":"https://ror.org/006hf6230","country_code":"NL","type":"education","lineage":["https://openalex.org/I94624287"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Jaap H. Buurke","raw_affiliation_strings":["Biomedical Signals and Systems, University of Twente, NL","Roessingh Research and Development, Enschede, NL"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Biomedical Signals and Systems, University of Twente, NL","institution_ids":["https://openalex.org/I94624287"]},{"raw_affiliation_string":"Roessingh Research and Development, Enschede, NL","institution_ids":["https://openalex.org/I4210104520"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5080611863","display_name":"Petrus H. Veltink","orcid":"https://orcid.org/0000-0002-1796-9999"},"institutions":[{"id":"https://openalex.org/I94624287","display_name":"University of Twente","ror":"https://ror.org/006hf6230","country_code":"NL","type":"education","lineage":["https://openalex.org/I94624287"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Peter H. Veltink","raw_affiliation_strings":["Biomedical Signals and Systems, University of Twente, NL"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Biomedical Signals and Systems, University of Twente, NL","institution_ids":["https://openalex.org/I94624287"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.4261,"has_fulltext":true,"cited_by_count":9,"citation_normalized_percentile":{"value":0.83364969,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10114","display_name":"Balance, Gait, and Falls Prevention","score":0.9959999918937683,"subfield":{"id":"https://openalex.org/subfields/3612","display_name":"Physical Therapy, Sports Therapy and Rehabilitation"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10114","display_name":"Balance, Gait, and Falls Prevention","score":0.9959999918937683,"subfield":{"id":"https://openalex.org/subfields/3612","display_name":"Physical Therapy, Sports Therapy and Rehabilitation"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T12740","display_name":"Gait Recognition and Analysis","score":0.9944999814033508,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11325","display_name":"Inertial Sensor and Navigation","score":0.9929999709129333,"subfield":{"id":"https://openalex.org/subfields/2202","display_name":"Aerospace Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/inertial-frame-of-reference","display_name":"Inertial frame of reference","score":0.6631201505661011},{"id":"https://openalex.org/keywords/units-of-measurement","display_name":"Units of measurement","score":0.5023198127746582},{"id":"https://openalex.org/keywords/inertial-measurement-unit","display_name":"Inertial measurement unit","score":0.47492533922195435},{"id":"https://openalex.org/keywords/distance-measurement","display_name":"Distance measurement","score":0.46931883692741394},{"id":"https://openalex.org/keywords/inertial-reference-unit","display_name":"Inertial reference unit","score":0.46694958209991455},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.39671987295150757},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3725101351737976},{"id":"https://openalex.org/keywords/inertial-navigation-system","display_name":"Inertial navigation system","score":0.36725080013275146},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.329933762550354},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.18421423435211182},{"id":"https://openalex.org/keywords/classical-mechanics","display_name":"Classical mechanics","score":0.0709494948387146}],"concepts":[{"id":"https://openalex.org/C173386949","wikidata":"https://www.wikidata.org/wiki/Q192735","display_name":"Inertial frame of reference","level":2,"score":0.6631201505661011},{"id":"https://openalex.org/C151233233","wikidata":"https://www.wikidata.org/wiki/Q47574","display_name":"Units of measurement","level":2,"score":0.5023198127746582},{"id":"https://openalex.org/C79061980","wikidata":"https://www.wikidata.org/wiki/Q941680","display_name":"Inertial measurement unit","level":2,"score":0.47492533922195435},{"id":"https://openalex.org/C2986158284","wikidata":"https://www.wikidata.org/wiki/Q6522493","display_name":"Distance measurement","level":2,"score":0.46931883692741394},{"id":"https://openalex.org/C189096121","wikidata":"https://www.wikidata.org/wiki/Q6028512","display_name":"Inertial reference unit","level":4,"score":0.46694958209991455},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.39671987295150757},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3725101351737976},{"id":"https://openalex.org/C128651787","wikidata":"https://www.wikidata.org/wiki/Q570607","display_name":"Inertial navigation system","level":3,"score":0.36725080013275146},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.329933762550354},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.18421423435211182},{"id":"https://openalex.org/C74650414","wikidata":"https://www.wikidata.org/wiki/Q11397","display_name":"Classical mechanics","level":1,"score":0.0709494948387146},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/sensors47125.2020.9278762","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sensors47125.2020.9278762","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 IEEE SENSORS","raw_type":"proceedings-article"},{"id":"pmh:oai:ris.utwente.nl:openaire/1609a88d-e725-4e04-979f-defa191766a2","is_oa":true,"landing_page_url":"https://research.utwente.nl/en/publications/1609a88d-e725-4e04-979f-defa191766a2","pdf_url":null,"source":{"id":"https://openalex.org/S4406922991","display_name":"University of Twente Research Information","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Mohamed Refai, M I, van Beijnum, B-J, Buurke, J H & Veltink, P H 2020, Portable Gait Lab : Instantaneous centre of mass velocity using three inertial measurement units. in 2020 IEEE Sensors., 9278762, Proceedings of IEEE Sensors, vol. 2020-October, IEEE, Piscataway, NJ, IEEE Sensors 2020, Virtual, Rotterdam, Netherlands, 25/10/20. https://doi.org/10.1109/SENSORS47125.2020.9278762","raw_type":"info:eu-repo/semantics/publishedVersion"},{"id":"pmh:oai:ris.utwente.nl:publications/1609a88d-e725-4e04-979f-defa191766a2","is_oa":true,"landing_page_url":"http://www.scopus.com/inward/record.url?scp=85092463032&partnerID=8YFLogxK","pdf_url":"https://ris.utwente.nl/ws/files/247952744/Refai2020portable.pdf","source":{"id":"https://openalex.org/S4406922991","display_name":"University of Twente Research Information","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Mohamed Refai, M I, van Beijnum, B-J, Buurke, J H & Veltink, P H 2020, Portable Gait Lab : Instantaneous centre of mass velocity using three inertial measurement units. in 2020 IEEE Sensors., 9278762, Proceedings of IEEE Sensors, vol. 2020-October, IEEE, Piscataway, NJ, IEEE Sensors 2020, Virtual, Rotterdam, Netherlands, 25/10/20. https://doi.org/10.1109/SENSORS47125.2020.9278762","raw_type":"info:eu-repo/semantics/publishedVersion"}],"best_oa_location":{"id":"pmh:oai:ris.utwente.nl:openaire/1609a88d-e725-4e04-979f-defa191766a2","is_oa":true,"landing_page_url":"https://research.utwente.nl/en/publications/1609a88d-e725-4e04-979f-defa191766a2","pdf_url":null,"source":{"id":"https://openalex.org/S4406922991","display_name":"University of Twente Research Information","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Mohamed Refai, M I, van Beijnum, B-J, Buurke, J H & Veltink, P H 2020, Portable Gait Lab : Instantaneous centre of mass velocity using three inertial measurement units. in 2020 IEEE Sensors., 9278762, Proceedings of IEEE Sensors, vol. 2020-October, IEEE, Piscataway, NJ, IEEE Sensors 2020, Virtual, Rotterdam, Netherlands, 25/10/20. https://doi.org/10.1109/SENSORS47125.2020.9278762","raw_type":"info:eu-repo/semantics/publishedVersion"},"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G6877850787","display_name":null,"funder_award_id":"14905","funder_id":"https://openalex.org/F4320321800","funder_display_name":"Nederlandse Organisatie voor Wetenschappelijk Onderzoek"}],"funders":[{"id":"https://openalex.org/F4320321800","display_name":"Nederlandse Organisatie voor Wetenschappelijk Onderzoek","ror":"https://ror.org/04jsz6e67"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W2005700828","https://openalex.org/W2060969870","https://openalex.org/W2073021377","https://openalex.org/W2085920063","https://openalex.org/W2098193909","https://openalex.org/W2160348526","https://openalex.org/W2555952628","https://openalex.org/W2565438365","https://openalex.org/W3016380002","https://openalex.org/W3080714114"],"related_works":["https://openalex.org/W3195533899","https://openalex.org/W1967422967","https://openalex.org/W1488373600","https://openalex.org/W1973973903","https://openalex.org/W2029881158","https://openalex.org/W2773722138","https://openalex.org/W2038183074","https://openalex.org/W4313886815","https://openalex.org/W2999148748","https://openalex.org/W2372501491"],"abstract_inverted_index":{"Estimating":[0],"instantaneous":[1],"3D":[2],"Centre":[3],"of":[4,65,75,95,128],"Mass":[5],"velocity":[6,130],"(VCOM)":[7],"using":[8,62,131],"wearables":[9],"can":[10],"improve":[11],"ambulatory":[12,126],"gait":[13,87],"monitoring.":[14],"Inertial":[15],"Measurement":[16],"Units":[17],"(IMU)":[18],"are":[19],"commonly":[20],"used":[21],"to":[22,110],"estimate":[23],"VCOM,":[24],"although,":[25],"studies":[26],"have":[27],"either":[28],"measured":[29,67],"only":[30],"the":[31,46,69,96,99],"magnitude,":[32],"or":[33],"use":[34],"machine":[35],"learning":[36],"methods.":[37],"Here,":[38],"we":[39],"propose":[40],"a":[41,51,104,123],"three":[42],"IMU":[43,100],"setup,":[44],"where":[45],"VCOM":[47,76,102],"is":[48,83],"obtained":[49,77],"by":[50],"complementary":[52],"filter":[53],"method.":[54],"This":[55,81,120],"method":[56,82,121],"fuses":[57],"high":[58],"frequency":[59,73],"information":[60,74],"achieved":[61],"strapdown":[63],"integration":[64],"accelerations":[66],"at":[68],"pelvis":[70],"with":[71],"low":[72],"from":[78],"foot":[79],"velocities.":[80],"applied":[84],"in":[85],"variable":[86],"which":[88],"includes":[89],"turns.":[90],"The":[91],"root":[92],"mean":[93],"square":[94],"error":[97],"between":[98],"estimated":[101],"against":[103],"reference":[105],"VICON":[106],"measurement":[107],"was":[108],"found":[109],"be":[111],"0.1":[112],"\u00b1":[113],"0.02":[114],"m/s":[115],"across":[116],"all":[117],"walking":[118],"tasks.":[119],"provides":[122],"drift":[124],"free":[125],"estimation":[127],"CoM":[129],"minimal":[132],"IMUs.":[133]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":3},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2020-12-21T00:00:00"}
