{"id":"https://openalex.org/W4200194330","doi":"https://doi.org/10.1109/sensors47087.2021.9639846","title":"A Wearable Cuffless Blood Pressure Sensor with Radio-Frequency Technology","display_name":"A Wearable Cuffless Blood Pressure Sensor with Radio-Frequency Technology","publication_year":2021,"publication_date":"2021-10-31","ids":{"openalex":"https://openalex.org/W4200194330","doi":"https://doi.org/10.1109/sensors47087.2021.9639846"},"language":"en","primary_location":{"id":"doi:10.1109/sensors47087.2021.9639846","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sensors47087.2021.9639846","pdf_url":null,"source":{"id":"https://openalex.org/S4363605007","display_name":"2021 IEEE Sensors","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 IEEE Sensors","raw_type":"proceedings-article"},"type":"conference-abstract","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5046035191","display_name":"Chao\u2010Hsiung Tseng","orcid":"https://orcid.org/0000-0003-2348-8646"},"institutions":[{"id":"https://openalex.org/I154864474","display_name":"National Taiwan University of Science and Technology","ror":"https://ror.org/00q09pe49","country_code":"TW","type":"education","lineage":["https://openalex.org/I154864474"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Chao-Hsiung Tseng","raw_affiliation_strings":["Department of Electronic and Computer Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electronic and Computer Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan","institution_ids":["https://openalex.org/I154864474"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5066527784","display_name":"Tzu-Jung Tseng","orcid":"https://orcid.org/0000-0001-9110-2798"},"institutions":[{"id":"https://openalex.org/I16733864","display_name":"National Taiwan University","ror":"https://ror.org/05bqach95","country_code":"TW","type":"education","lineage":["https://openalex.org/I16733864"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Tzu-Jung Tseng","raw_affiliation_strings":["Graduate Institute of Communication Engineering, National Taiwan University, Taipei, Taiwan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Graduate Institute of Communication Engineering, National Taiwan University, Taipei, Taiwan","institution_ids":["https://openalex.org/I16733864"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"1"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9883999824523926,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9883999824523926,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10205","display_name":"Advanced Fiber Optic Sensors","score":0.933899998664856,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/sphygmomanometer","display_name":"Sphygmomanometer","score":0.6248141527175903},{"id":"https://openalex.org/keywords/demodulation","display_name":"Demodulation","score":0.6146029829978943},{"id":"https://openalex.org/keywords/blood-pressure","display_name":"Blood pressure","score":0.5963100790977478},{"id":"https://openalex.org/keywords/wearable-computer","display_name":"Wearable computer","score":0.5863246321678162},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.5076113939285278},{"id":"https://openalex.org/keywords/photoplethysmogram","display_name":"Photoplethysmogram","score":0.49897289276123047},{"id":"https://openalex.org/keywords/pressure-sensor","display_name":"Pressure sensor","score":0.49566352367401123},{"id":"https://openalex.org/keywords/waveform","display_name":"Waveform","score":0.49127453565597534},{"id":"https://openalex.org/keywords/pulse","display_name":"Pulse (music)","score":0.4900768995285034},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.3859971761703491},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.35940104722976685},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.3547772765159607},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.2820691168308258},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.2602190673351288},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.25592148303985596},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.24627888202667236},{"id":"https://openalex.org/keywords/detector","display_name":"Detector","score":0.1782187819480896},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.1734258234500885},{"id":"https://openalex.org/keywords/internal-medicine","display_name":"Internal medicine","score":0.08920818567276001}],"concepts":[{"id":"https://openalex.org/C2910533495","wikidata":"https://www.wikidata.org/wiki/Q503968","display_name":"Sphygmomanometer","level":3,"score":0.6248141527175903},{"id":"https://openalex.org/C195251586","wikidata":"https://www.wikidata.org/wiki/Q1185939","display_name":"Demodulation","level":3,"score":0.6146029829978943},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.5963100790977478},{"id":"https://openalex.org/C150594956","wikidata":"https://www.wikidata.org/wiki/Q1334829","display_name":"Wearable computer","level":2,"score":0.5863246321678162},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.5076113939285278},{"id":"https://openalex.org/C116390426","wikidata":"https://www.wikidata.org/wiki/Q7187885","display_name":"Photoplethysmogram","level":3,"score":0.49897289276123047},{"id":"https://openalex.org/C41325743","wikidata":"https://www.wikidata.org/wiki/Q1261040","display_name":"Pressure sensor","level":2,"score":0.49566352367401123},{"id":"https://openalex.org/C197424946","wikidata":"https://www.wikidata.org/wiki/Q1165717","display_name":"Waveform","level":3,"score":0.49127453565597534},{"id":"https://openalex.org/C2780167933","wikidata":"https://www.wikidata.org/wiki/Q1550652","display_name":"Pulse (music)","level":3,"score":0.4900768995285034},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3859971761703491},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.35940104722976685},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.3547772765159607},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.2820691168308258},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.2602190673351288},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.25592148303985596},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.24627888202667236},{"id":"https://openalex.org/C94915269","wikidata":"https://www.wikidata.org/wiki/Q1834857","display_name":"Detector","level":2,"score":0.1782187819480896},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.1734258234500885},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.08920818567276001},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.0},{"id":"https://openalex.org/C554190296","wikidata":"https://www.wikidata.org/wiki/Q47528","display_name":"Radar","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/sensors47087.2021.9639846","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sensors47087.2021.9639846","pdf_url":null,"source":{"id":"https://openalex.org/S4363605007","display_name":"2021 IEEE Sensors","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 IEEE Sensors","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","display_name":"Good health and well-being","score":0.7699999809265137}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2732360296","https://openalex.org/W1994871954","https://openalex.org/W110588529","https://openalex.org/W3089926590","https://openalex.org/W4205793574","https://openalex.org/W4225612652","https://openalex.org/W2898902003","https://openalex.org/W3165418382","https://openalex.org/W2768794232","https://openalex.org/W2920532663"],"abstract_inverted_index":{"A":[0,18],"wearable":[1],"cuffless":[2],"blood":[3,57,60,72],"pressure":[4,73],"sensor":[5,23,74,89],"is":[6,24,47],"developed":[7,88],"and":[8,33],"verified":[9],"in":[10],"this":[11],"talk":[12],"based":[13],"on":[14],"the":[15,19,38,51,56,70,87,94],"radio-frequency":[16],"technology.":[17],"near-field":[20],"self-injection-locked":[21],"(NFSIL)":[22],"implemented":[25],"by":[26,93],"integrating":[27],"a":[28,76],"self-oscillating":[29],"complementary":[30],"split-ring":[31],"resonator":[32],"an":[34],"amplitude-based":[35],"demodulator":[36],"for":[37,79],"wrist":[39],"pulse":[40,44,52],"detection.":[41],"The":[42,59,83],"reflective":[43],"transit":[45],"time":[46,78],"then":[48],"extracted":[49],"from":[50],"waveform":[53],"to":[54],"estimate":[55],"pressures.":[58],"pressures":[61],"of":[62],"three":[63],"young":[64],"healthy":[65],"subjects":[66],"are":[67],"measured":[68,84],"using":[69,86],"NFSIL":[71],"at":[75],"designated":[77],"continuous":[80],"eight":[81],"days.":[82],"results":[85],"agree":[90],"those":[91],"acquired":[92],"commercial":[95],"sphygmomanometer":[96],"well.":[97]},"counts_by_year":[],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
