{"id":"https://openalex.org/W4200406097","doi":"https://doi.org/10.1109/sensors47087.2021.9639641","title":"Low-Cost NB-IoT Microgrid Power Quality Monitoring System","display_name":"Low-Cost NB-IoT Microgrid Power Quality Monitoring System","publication_year":2021,"publication_date":"2021-10-31","ids":{"openalex":"https://openalex.org/W4200406097","doi":"https://doi.org/10.1109/sensors47087.2021.9639641"},"language":"en","primary_location":{"id":"doi:10.1109/sensors47087.2021.9639641","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sensors47087.2021.9639641","pdf_url":null,"source":{"id":"https://openalex.org/S4363605007","display_name":"2021 IEEE Sensors","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 IEEE Sensors","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5013381681","display_name":"Dmitry A. Petrov","orcid":"https://orcid.org/0000-0001-7228-2471"},"institutions":[{"id":"https://openalex.org/I206945453","display_name":"Paderborn University","ror":"https://ror.org/058kzsd48","country_code":"DE","type":"education","lineage":["https://openalex.org/I206945453"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Dmitry Petrov","raw_affiliation_strings":["Sensor Technology Group, Paderborn University, Paderborn, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Sensor Technology Group, Paderborn University, Paderborn, Germany","institution_ids":["https://openalex.org/I206945453"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5068297579","display_name":"Konstantin Kroschewski","orcid":null},"institutions":[{"id":"https://openalex.org/I206945453","display_name":"Paderborn University","ror":"https://ror.org/058kzsd48","country_code":"DE","type":"education","lineage":["https://openalex.org/I206945453"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Konstantin Kroschewski","raw_affiliation_strings":["Sensor Technology Group, Paderborn University, Paderborn, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Sensor Technology Group, Paderborn University, Paderborn, Germany","institution_ids":["https://openalex.org/I206945453"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5086610520","display_name":"Ibrahim Mwammenywa","orcid":"https://orcid.org/0000-0003-2735-643X"},"institutions":[{"id":"https://openalex.org/I182078086","display_name":"University of Dar es Salaam","ror":"https://ror.org/0479aed98","country_code":"TZ","type":"education","lineage":["https://openalex.org/I182078086"]},{"id":"https://openalex.org/I206945453","display_name":"Paderborn University","ror":"https://ror.org/058kzsd48","country_code":"DE","type":"education","lineage":["https://openalex.org/I206945453"]}],"countries":["DE","TZ"],"is_corresponding":false,"raw_author_name":"Ibrahim Mwammenywa","raw_affiliation_strings":["Department of Electrical Engineering, University of Dar es Salaam, Dar es Salaam, Tanzania","Sensor Technology Group, Paderborn University, Paderborn, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, University of Dar es Salaam, Dar es Salaam, Tanzania","institution_ids":["https://openalex.org/I182078086"]},{"raw_affiliation_string":"Sensor Technology Group, Paderborn University, Paderborn, Germany","institution_ids":["https://openalex.org/I206945453"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5035843289","display_name":"Geoffrey Mark Kagarura","orcid":null},"institutions":[{"id":"https://openalex.org/I206945453","display_name":"Paderborn University","ror":"https://ror.org/058kzsd48","country_code":"DE","type":"education","lineage":["https://openalex.org/I206945453"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"G. Mark Kagarura","raw_affiliation_strings":["Sensor Technology Group, Paderborn University, Paderborn, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Sensor Technology Group, Paderborn University, Paderborn, Germany","institution_ids":["https://openalex.org/I206945453"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5091462785","display_name":"Ulrich Hilleringmann","orcid":"https://orcid.org/0000-0002-1621-0067"},"institutions":[{"id":"https://openalex.org/I206945453","display_name":"Paderborn University","ror":"https://ror.org/058kzsd48","country_code":"DE","type":"education","lineage":["https://openalex.org/I206945453"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Ulrich Hilleringmann","raw_affiliation_strings":["Sensor Technology Group, Paderborn University, Paderborn, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Sensor Technology Group, Paderborn University, Paderborn, Germany","institution_ids":["https://openalex.org/I206945453"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.849,"has_fulltext":false,"cited_by_count":9,"citation_normalized_percentile":{"value":0.92158016,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11392","display_name":"Energy Harvesting in Wireless Networks","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.9319807887077332},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6639564633369446},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.5256415605545044},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.5196753144264221},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.482428640127182},{"id":"https://openalex.org/keywords/narrowband","display_name":"Narrowband","score":0.48142120242118835},{"id":"https://openalex.org/keywords/internet-of-things","display_name":"Internet of Things","score":0.47169163823127747},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4654339849948883},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.45260894298553467},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.42479202151298523},{"id":"https://openalex.org/keywords/energy-management-system","display_name":"Energy management system","score":0.4182766079902649},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.3774532675743103},{"id":"https://openalex.org/keywords/energy-management","display_name":"Energy management","score":0.3773013651371002},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.33579760789871216},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.31742626428604126},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.3095844089984894},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.2777588963508606},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.24590501189231873},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.1697539985179901}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.9319807887077332},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6639564633369446},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.5256415605545044},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.5196753144264221},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.482428640127182},{"id":"https://openalex.org/C2776096036","wikidata":"https://www.wikidata.org/wiki/Q1140483","display_name":"Narrowband","level":2,"score":0.48142120242118835},{"id":"https://openalex.org/C81860439","wikidata":"https://www.wikidata.org/wiki/Q251212","display_name":"Internet of Things","level":2,"score":0.47169163823127747},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4654339849948883},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.45260894298553467},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.42479202151298523},{"id":"https://openalex.org/C2781260460","wikidata":"https://www.wikidata.org/wiki/Q6139999","display_name":"Energy management system","level":4,"score":0.4182766079902649},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.3774532675743103},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.3773013651371002},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.33579760789871216},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.31742626428604126},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.3095844089984894},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.2777588963508606},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.24590501189231873},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.1697539985179901},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/sensors47087.2021.9639641","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sensors47087.2021.9639641","pdf_url":null,"source":{"id":"https://openalex.org/S4363605007","display_name":"2021 IEEE Sensors","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 IEEE Sensors","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8799999952316284,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W2061202337","https://openalex.org/W2062193070","https://openalex.org/W2116908952","https://openalex.org/W2150773759","https://openalex.org/W2185118931","https://openalex.org/W2788020135","https://openalex.org/W2918970469","https://openalex.org/W2922469213","https://openalex.org/W2990841348","https://openalex.org/W3005465314","https://openalex.org/W4231061261","https://openalex.org/W4250261774"],"related_works":["https://openalex.org/W2333017163","https://openalex.org/W2964937504","https://openalex.org/W2169268775","https://openalex.org/W2749199243","https://openalex.org/W2142933425","https://openalex.org/W4366813529","https://openalex.org/W4220876800","https://openalex.org/W2333530803","https://openalex.org/W2347673489","https://openalex.org/W2371966636"],"abstract_inverted_index":{"For":[0],"small":[1],"to":[2,56,59],"medium-sized":[3],"renewable":[4],"energy":[5],"dependent":[6],"microgrids,":[7],"large":[8],"imbalances":[9],"between":[10],"generated":[11],"and":[12,93],"consumed":[13],"electricity":[14],"exist.":[15],"These":[16],"fluctuations":[17],"coupled":[18],"with":[19],"other":[20],"operational":[21],"constraints":[22],"result":[23],"in":[24,31,54],"distortion":[25],"of":[26,75],"the":[27,39,84],"power":[28,33,67],"quality,":[29],"resulting":[30],"frequent":[32],"outages.":[34],"To":[35],"address":[36],"this":[37,62],"problem,":[38],"microgrids":[40],"must":[41],"be":[42],"real-time":[43],"monitored":[44],"at":[45,88],"distributed":[46],"locations":[47],"by":[48],"cost-effective,":[49],"high":[50],"accuracy,":[51],"responsive":[52],"systems":[53],"order":[55],"respond":[57],"quickly":[58],"imbalances.":[60],"In":[61],"paper":[63],"a":[64,99],"low-cost":[65],"wireless":[66],"quality":[68],"monitoring":[69,85],"system":[70,82],"based":[71],"on":[72],"Narrowband":[73],"Internet":[74],"Things":[76],"(NB-IoT)":[77],"technology":[78],"is":[79],"implemented.":[80],"The":[81],"includes":[83],"PCB":[86],"assembled":[87],"Paderborn":[89],"University,":[90],"management":[91],"portal":[92],"enables":[94],"various":[95],"micro-grid":[96],"functions":[97],"via":[98],"remote":[100],"server.":[101]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":3},{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":1}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
