{"id":"https://openalex.org/W4387123603","doi":"https://doi.org/10.1109/sbcci60457.2023.10261666","title":"Addressing Single-Event-Multiple-Transient Faults in Asynchronous RH-Click Controllers","display_name":"Addressing Single-Event-Multiple-Transient Faults in Asynchronous RH-Click Controllers","publication_year":2023,"publication_date":"2023-08-28","ids":{"openalex":"https://openalex.org/W4387123603","doi":"https://doi.org/10.1109/sbcci60457.2023.10261666"},"language":"en","primary_location":{"id":"doi:10.1109/sbcci60457.2023.10261666","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/sbcci60457.2023.10261666","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 36th SBC/SBMicro/IEEE/ACM Symposium on Integrated Circuits and Systems Design (SBCCI)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5007948704","display_name":"Felipe A. Kuentzer","orcid":"https://orcid.org/0000-0003-3177-372X"},"institutions":[{"id":"https://openalex.org/I96578850","display_name":"Leibniz Institute for Neurobiology","ror":"https://ror.org/01zwmgk08","country_code":"DE","type":"facility","lineage":["https://openalex.org/I315704651","https://openalex.org/I96578850"]}],"countries":["DE"],"is_corresponding":true,"raw_author_name":"Felipe A. Kuentzer","raw_affiliation_strings":["Leibniz-Institut f&#x00FC;r Innovative Mikroelektronik (IHP),Frankfurt,Germany,15236"],"affiliations":[{"raw_affiliation_string":"Leibniz-Institut f&#x00FC;r Innovative Mikroelektronik (IHP),Frankfurt,Germany,15236","institution_ids":["https://openalex.org/I96578850"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5015586753","display_name":"Christos Georgakidis","orcid":"https://orcid.org/0000-0002-7491-2606"},"institutions":[{"id":"https://openalex.org/I145722265","display_name":"University of Thessaly","ror":"https://ror.org/04v4g9h31","country_code":"GR","type":"education","lineage":["https://openalex.org/I145722265"]}],"countries":["GR"],"is_corresponding":false,"raw_author_name":"Christos Georgakidis","raw_affiliation_strings":["University of Thessaly,Department of Electrical and Computer Engineering,Volos,Greece,38221"],"affiliations":[{"raw_affiliation_string":"University of Thessaly,Department of Electrical and Computer Engineering,Volos,Greece,38221","institution_ids":["https://openalex.org/I145722265"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5103066371","display_name":"Christos Sotiriou","orcid":"https://orcid.org/0000-0001-9318-474X"},"institutions":[{"id":"https://openalex.org/I145722265","display_name":"University of Thessaly","ror":"https://ror.org/04v4g9h31","country_code":"GR","type":"education","lineage":["https://openalex.org/I145722265"]}],"countries":["GR"],"is_corresponding":false,"raw_author_name":"Christos Sotiriou","raw_affiliation_strings":["University of Thessaly,Department of Electrical and Computer Engineering,Volos,Greece,38221"],"affiliations":[{"raw_affiliation_string":"University of Thessaly,Department of Electrical and Computer Engineering,Volos,Greece,38221","institution_ids":["https://openalex.org/I145722265"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5004959402","display_name":"Milo\u0161 Krsti\u0107","orcid":"https://orcid.org/0000-0003-0267-0203"},"institutions":[{"id":"https://openalex.org/I176453806","display_name":"University of Potsdam","ror":"https://ror.org/03bnmw459","country_code":"DE","type":"education","lineage":["https://openalex.org/I176453806"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Milos Krstic","raw_affiliation_strings":["University of Potsdam,Potsdam,Germany,14469"],"affiliations":[{"raw_affiliation_string":"University of Potsdam,Potsdam,Germany,14469","institution_ids":["https://openalex.org/I176453806"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5007948704"],"corresponding_institution_ids":["https://openalex.org/I96578850"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.11323702,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11005","display_name":"Radiation Effects in Electronics","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11005","display_name":"Radiation Effects in Electronics","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10363","display_name":"Low-power high-performance VLSI design","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11032","display_name":"VLSI and Analog Circuit Testing","score":0.9965999722480774,"subfield":{"id":"https://openalex.org/subfields/1708","display_name":"Hardware and Architecture"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/asynchronous-communication","display_name":"Asynchronous communication","score":0.8805174827575684},{"id":"https://openalex.org/keywords/robustness","display_name":"Robustness (evolution)","score":0.809457540512085},{"id":"https://openalex.org/keywords/very-large-scale-integration","display_name":"Very-large-scale integration","score":0.6547524333000183},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6538721323013306},{"id":"https://openalex.org/keywords/combinational-logic","display_name":"Combinational logic","score":0.6311965584754944},{"id":"https://openalex.org/keywords/single-event-upset","display_name":"Single event upset","score":0.5885034799575806},{"id":"https://openalex.org/keywords/asynchronous-circuit","display_name":"Asynchronous circuit","score":0.49932861328125},{"id":"https://openalex.org/keywords/soft-error","display_name":"Soft error","score":0.4759887456893921},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.455710232257843},{"id":"https://openalex.org/keywords/radiation-hardening","display_name":"Radiation hardening","score":0.4471853971481323},{"id":"https://openalex.org/keywords/critical-path-method","display_name":"Critical path method","score":0.42780566215515137},{"id":"https://openalex.org/keywords/logic-gate","display_name":"Logic gate","score":0.41289445757865906},{"id":"https://openalex.org/keywords/computer-engineering","display_name":"Computer engineering","score":0.4093974232673645},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.38196223974227905},{"id":"https://openalex.org/keywords/electronic-circuit","display_name":"Electronic circuit","score":0.33866602182388306},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.24572202563285828},{"id":"https://openalex.org/keywords/computer-hardware","display_name":"Computer hardware","score":0.24190974235534668},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.19846725463867188},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.13907212018966675},{"id":"https://openalex.org/keywords/detector","display_name":"Detector","score":0.12315374612808228},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.11120525002479553}],"concepts":[{"id":"https://openalex.org/C151319957","wikidata":"https://www.wikidata.org/wiki/Q752739","display_name":"Asynchronous communication","level":2,"score":0.8805174827575684},{"id":"https://openalex.org/C63479239","wikidata":"https://www.wikidata.org/wiki/Q7353546","display_name":"Robustness (evolution)","level":3,"score":0.809457540512085},{"id":"https://openalex.org/C14580979","wikidata":"https://www.wikidata.org/wiki/Q876049","display_name":"Very-large-scale integration","level":2,"score":0.6547524333000183},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6538721323013306},{"id":"https://openalex.org/C81409106","wikidata":"https://www.wikidata.org/wiki/Q76505","display_name":"Combinational logic","level":3,"score":0.6311965584754944},{"id":"https://openalex.org/C2780073065","wikidata":"https://www.wikidata.org/wiki/Q1476733","display_name":"Single event upset","level":3,"score":0.5885034799575806},{"id":"https://openalex.org/C87695204","wikidata":"https://www.wikidata.org/wiki/Q629971","display_name":"Asynchronous circuit","level":5,"score":0.49932861328125},{"id":"https://openalex.org/C154474529","wikidata":"https://www.wikidata.org/wiki/Q1658917","display_name":"Soft error","level":2,"score":0.4759887456893921},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.455710232257843},{"id":"https://openalex.org/C119349744","wikidata":"https://www.wikidata.org/wiki/Q3026015","display_name":"Radiation hardening","level":3,"score":0.4471853971481323},{"id":"https://openalex.org/C115874739","wikidata":"https://www.wikidata.org/wiki/Q825377","display_name":"Critical path method","level":2,"score":0.42780566215515137},{"id":"https://openalex.org/C131017901","wikidata":"https://www.wikidata.org/wiki/Q170451","display_name":"Logic gate","level":2,"score":0.41289445757865906},{"id":"https://openalex.org/C113775141","wikidata":"https://www.wikidata.org/wiki/Q428691","display_name":"Computer engineering","level":1,"score":0.4093974232673645},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.38196223974227905},{"id":"https://openalex.org/C134146338","wikidata":"https://www.wikidata.org/wiki/Q1815901","display_name":"Electronic circuit","level":2,"score":0.33866602182388306},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.24572202563285828},{"id":"https://openalex.org/C9390403","wikidata":"https://www.wikidata.org/wiki/Q3966","display_name":"Computer hardware","level":1,"score":0.24190974235534668},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.19846725463867188},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.13907212018966675},{"id":"https://openalex.org/C94915269","wikidata":"https://www.wikidata.org/wiki/Q1834857","display_name":"Detector","level":2,"score":0.12315374612808228},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.11120525002479553},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.0},{"id":"https://openalex.org/C68043766","wikidata":"https://www.wikidata.org/wiki/Q267416","display_name":"Static random-access memory","level":2,"score":0.0},{"id":"https://openalex.org/C137059387","wikidata":"https://www.wikidata.org/wiki/Q426882","display_name":"Clock signal","level":3,"score":0.0},{"id":"https://openalex.org/C104317684","wikidata":"https://www.wikidata.org/wiki/Q7187","display_name":"Gene","level":2,"score":0.0},{"id":"https://openalex.org/C42196554","wikidata":"https://www.wikidata.org/wiki/Q1186179","display_name":"Synchronous circuit","level":4,"score":0.0},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/sbcci60457.2023.10261666","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/sbcci60457.2023.10261666","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 36th SBC/SBMicro/IEEE/ACM Symposium on Integrated Circuits and Systems Design (SBCCI)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.4699999988079071,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":33,"referenced_works":["https://openalex.org/W1592886836","https://openalex.org/W2000632602","https://openalex.org/W2060903533","https://openalex.org/W2071068906","https://openalex.org/W2071429830","https://openalex.org/W2079492534","https://openalex.org/W2086376532","https://openalex.org/W2097708006","https://openalex.org/W2098426274","https://openalex.org/W2102327177","https://openalex.org/W2122995125","https://openalex.org/W2130975540","https://openalex.org/W2147504603","https://openalex.org/W2151830106","https://openalex.org/W2193563574","https://openalex.org/W2290529364","https://openalex.org/W2294420364","https://openalex.org/W2560410485","https://openalex.org/W2579875234","https://openalex.org/W2769996234","https://openalex.org/W2803051631","https://openalex.org/W2928843358","https://openalex.org/W2998784970","https://openalex.org/W3034301158","https://openalex.org/W3040935927","https://openalex.org/W3046969749","https://openalex.org/W3082782712","https://openalex.org/W3104812533","https://openalex.org/W3108693540","https://openalex.org/W3208095669","https://openalex.org/W4240812976","https://openalex.org/W6681929348","https://openalex.org/W6787158073"],"related_works":["https://openalex.org/W2622269177","https://openalex.org/W1523508240","https://openalex.org/W2102538861","https://openalex.org/W2122334461","https://openalex.org/W2165400042","https://openalex.org/W4211237868","https://openalex.org/W2086616086","https://openalex.org/W4221121827","https://openalex.org/W4394891841","https://openalex.org/W2077268733"],"abstract_inverted_index":{"Technology":[0],"shrinking":[1],"has":[2,65],"allowed":[3],"major":[4],"improvements":[5],"through":[6],"the":[7,11,47,90,102,132],"last":[8],"decades,":[9],"from":[10,76],"increased":[12],"performance":[13],"and":[14,24,85,114,122],"design":[15,58],"complexity":[16],"while":[17],"maintaining":[18],"circuit":[19],"area":[20],"to":[21,43,51,69,72,110,120],"more":[22,41],"reliable":[23],"power-efficient":[25],"Integrated":[26],"Circuits":[27],"(ICs).":[28],"However,":[29],"with":[30,59],"smaller":[31],"transistors,":[32],"especially":[33],"in":[34,46,138],"harsh":[35],"environments,":[36],"modern":[37,96],"chips":[38],"are":[39,83],"becoming":[40],"susceptible":[42],"Single-Event-Multiple-Transients":[44],"(SEMTs)":[45],"combinational":[48],"logic":[49],"due":[50],"radiation":[52],"effects.":[53],"The":[54],"combination":[55],"of":[56,86,95],"asynchronous":[57,103],"Radiation":[60,104],"Hardened":[61,105],"by":[62],"Design":[63],"(RHBD)":[64],"shown":[66],"great":[67,87],"potential":[68],"increase":[70],"robustness":[71,109],"soft":[73],"errors":[74],"arising":[75],"Single-Event-Transients":[77],"(SETs),":[78],"but":[79],"detailed":[80],"SEMT":[81,111],"analyses":[82],"missing":[84],"concern":[88],"for":[89],"future":[91],"that":[92,131],"lies":[93],"ahead":[94],"VLSI":[97],"systems.":[98],"In":[99],"this":[100],"paper,":[101],"(RH)":[106],"Click":[107],"controller's":[108],"is":[112,118,136],"accessed,":[113],"a":[115],"post-placement":[116],"approach":[117],"proposed":[119,133],"group":[121],"space":[123],"critical":[124],"cells":[125],"apart.":[126],"Fault":[127],"simulation":[128],"experiments":[129],"demonstrate":[130],"spacing":[134],"strategy":[135],"effective":[137],"mitigating":[139],"SEMTs.":[140]},"counts_by_year":[],"updated_date":"2025-12-25T23:11:45.687758","created_date":"2025-10-10T00:00:00"}
