{"id":"https://openalex.org/W2415104123","doi":"https://doi.org/10.1109/sas.2016.7479831","title":"Ultrasonic transducer positioning system for clamp-on flowmeter applications","display_name":"Ultrasonic transducer positioning system for clamp-on flowmeter applications","publication_year":2016,"publication_date":"2016-04-01","ids":{"openalex":"https://openalex.org/W2415104123","doi":"https://doi.org/10.1109/sas.2016.7479831","mag":"2415104123"},"language":"en","primary_location":{"id":"doi:10.1109/sas.2016.7479831","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sas.2016.7479831","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 IEEE Sensors Applications Symposium (SAS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5059085873","display_name":"Anett Bailleu","orcid":null},"institutions":[{"id":"https://openalex.org/I122228004","display_name":"HTW Berlin - University of Applied Sciences","ror":"https://ror.org/01xzwj424","country_code":"DE","type":"education","lineage":["https://openalex.org/I122228004"]}],"countries":["DE"],"is_corresponding":true,"raw_author_name":"Anett Bailleu","raw_affiliation_strings":["Department 1 - Energy and Information- Electrical Engineering, HTW Berlin University of Applied Sciences, Berlin, Germany"],"affiliations":[{"raw_affiliation_string":"Department 1 - Energy and Information- Electrical Engineering, HTW Berlin University of Applied Sciences, Berlin, Germany","institution_ids":["https://openalex.org/I122228004"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5059085873"],"corresponding_institution_ids":["https://openalex.org/I122228004"],"apc_list":null,"apc_paid":null,"fwci":0.5725,"has_fulltext":false,"cited_by_count":6,"citation_normalized_percentile":{"value":0.66781931,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12537","display_name":"Flow Measurement and Analysis","score":0.9886000156402588,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12537","display_name":"Flow Measurement and Analysis","score":0.9886000156402588,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12564","display_name":"Sensor Technology and Measurement Systems","score":0.9570000171661377,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14353","display_name":"Wireless Sensor Networks for Data Analysis","score":0.9362000226974487,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/transducer","display_name":"Transducer","score":0.8684014081954956},{"id":"https://openalex.org/keywords/ultrasonic-sensor","display_name":"Ultrasonic sensor","score":0.8245846033096313},{"id":"https://openalex.org/keywords/clamp","display_name":"Clamp","score":0.7771871089935303},{"id":"https://openalex.org/keywords/ultrasonic-flow-meter","display_name":"Ultrasonic flow meter","score":0.7026697397232056},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.6723088026046753},{"id":"https://openalex.org/keywords/flow-measurement","display_name":"Flow measurement","score":0.5514711141586304},{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.5362619161605835},{"id":"https://openalex.org/keywords/capacitive-micromachined-ultrasonic-transducers","display_name":"Capacitive micromachined ultrasonic transducers","score":0.5127940773963928},{"id":"https://openalex.org/keywords/process","display_name":"Process (computing)","score":0.444099485874176},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4433099925518036},{"id":"https://openalex.org/keywords/positioning-system","display_name":"Positioning system","score":0.42234712839126587},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3341776728630066},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.27312204241752625},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.12246546149253845},{"id":"https://openalex.org/keywords/computer-vision","display_name":"Computer vision","score":0.10083511471748352}],"concepts":[{"id":"https://openalex.org/C56318395","wikidata":"https://www.wikidata.org/wiki/Q215928","display_name":"Transducer","level":2,"score":0.8684014081954956},{"id":"https://openalex.org/C81288441","wikidata":"https://www.wikidata.org/wiki/Q20736125","display_name":"Ultrasonic sensor","level":2,"score":0.8245846033096313},{"id":"https://openalex.org/C2776161997","wikidata":"https://www.wikidata.org/wiki/Q846600","display_name":"Clamp","level":3,"score":0.7771871089935303},{"id":"https://openalex.org/C63066824","wikidata":"https://www.wikidata.org/wiki/Q2165466","display_name":"Ultrasonic flow meter","level":3,"score":0.7026697397232056},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.6723088026046753},{"id":"https://openalex.org/C16302685","wikidata":"https://www.wikidata.org/wiki/Q15091623","display_name":"Flow measurement","level":2,"score":0.5514711141586304},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.5362619161605835},{"id":"https://openalex.org/C58772458","wikidata":"https://www.wikidata.org/wiki/Q5034480","display_name":"Capacitive micromachined ultrasonic transducers","level":3,"score":0.5127940773963928},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.444099485874176},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4433099925518036},{"id":"https://openalex.org/C2778603505","wikidata":"https://www.wikidata.org/wiki/Q17141406","display_name":"Positioning system","level":3,"score":0.42234712839126587},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3341776728630066},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.27312204241752625},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.12246546149253845},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.10083511471748352},{"id":"https://openalex.org/C84111939","wikidata":"https://www.wikidata.org/wiki/Q5125465","display_name":"Clamping","level":2,"score":0.0},{"id":"https://openalex.org/C62611344","wikidata":"https://www.wikidata.org/wiki/Q1062658","display_name":"Node (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/sas.2016.7479831","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sas.2016.7479831","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 IEEE Sensors Applications Symposium (SAS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.6399999856948853,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2357308978","https://openalex.org/W2371824631","https://openalex.org/W2350425252","https://openalex.org/W2351040364","https://openalex.org/W2354654388","https://openalex.org/W2005252818","https://openalex.org/W2906209913","https://openalex.org/W2380694726","https://openalex.org/W1991603422","https://openalex.org/W2027530913"],"abstract_inverted_index":{"The":[0,50],"positions":[1],"of":[2,6,19,42,44,79],"the":[3,14,17,20,45,65,69,80,88],"ultrasonic":[4,31],"transducers":[5],"clamp-on":[7,32,70],"flowmeters":[8],"have":[9],"a":[10,26,59],"determining":[11],"influence":[12],"on":[13],"precision":[15],"and":[16,47],"accuracy":[18],"measurement":[21],"results.":[22],"In":[23],"this":[24],"paper":[25],"transducer":[27,56],"positioning":[28,51],"system":[29,52,89],"for":[30,58],"sensor":[33],"applications":[34],"is":[35],"presented.":[36],"It":[37],"was":[38],"designed":[39],"in":[40,87],"result":[41],"studies":[43],"sensitivity":[46],"works":[48],"automatically.":[49],"found":[53],"an":[54],"optimal":[55],"position":[57],"special":[60,77],"application":[61,81],"by":[62],"itself.":[63],"So,":[64],"user":[66],"can":[67],"operate":[68],"flowmeter":[71],"with":[72],"neither":[73],"finding":[74],"out":[75],"some":[76],"information":[78],"process":[82],"nor":[83],"setting":[84],"any":[85],"parameters":[86],"before.":[90]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2017,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
