{"id":"https://openalex.org/W2125126335","doi":"https://doi.org/10.1109/samos.2011.6045476","title":"Analyzing the performance and energy impact of 3D memory integration on embedded DSPs","display_name":"Analyzing the performance and energy impact of 3D memory integration on embedded DSPs","publication_year":2011,"publication_date":"2011-07-01","ids":{"openalex":"https://openalex.org/W2125126335","doi":"https://doi.org/10.1109/samos.2011.6045476","mag":"2125126335"},"language":"en","primary_location":{"id":"doi:10.1109/samos.2011.6045476","is_oa":false,"landing_page_url":"https://doi.org/10.1109/samos.2011.6045476","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 International Conference on Embedded Computer Systems: Architectures, Modeling and Simulation","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5088178230","display_name":"Daniel W. Chang","orcid":null},"institutions":[{"id":"https://openalex.org/I135310074","display_name":"University of Wisconsin\u2013Madison","ror":"https://ror.org/01y2jtd41","country_code":"US","type":"education","lineage":["https://openalex.org/I135310074"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Daniel W. Chang","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Wisconsin, Madison, Madison, WI, USA","Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, WI, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Wisconsin, Madison, Madison, WI, USA","institution_ids":["https://openalex.org/I135310074"]},{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, WI, USA","institution_ids":["https://openalex.org/I135310074"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5015340530","display_name":"Nam S. Kim","orcid":null},"institutions":[{"id":"https://openalex.org/I135310074","display_name":"University of Wisconsin\u2013Madison","ror":"https://ror.org/01y2jtd41","country_code":"US","type":"education","lineage":["https://openalex.org/I135310074"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Nam S. Kim","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Wisconsin, Madison, Madison, WI, USA","Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, WI, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Wisconsin, Madison, Madison, WI, USA","institution_ids":["https://openalex.org/I135310074"]},{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, WI, USA","institution_ids":["https://openalex.org/I135310074"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5103196891","display_name":"Michael Schulte","orcid":"https://orcid.org/0000-0003-1305-406X"},"institutions":[{"id":"https://openalex.org/I1311921367","display_name":"Advanced Micro Devices (Canada)","ror":"https://ror.org/02yh0k313","country_code":"CA","type":"company","lineage":["https://openalex.org/I1311921367","https://openalex.org/I4210137977"]},{"id":"https://openalex.org/I4210137977","display_name":"Advanced Micro Devices (United States)","ror":"https://ror.org/04kd6c783","country_code":"US","type":"company","lineage":["https://openalex.org/I4210137977"]}],"countries":["CA","US"],"is_corresponding":false,"raw_author_name":"Michael J. Schulte","raw_affiliation_strings":["Research and Advanced Development Laboratories, Advanced Micro Devices (AMD), Austin, TX, USA","Research and Advanced Development Labs, Advanced Micro Devices (AMD), Austin, TX, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Research and Advanced Development Laboratories, Advanced Micro Devices (AMD), Austin, TX, USA","institution_ids":["https://openalex.org/I4210137977"]},{"raw_affiliation_string":"Research and Advanced Development Labs, Advanced Micro Devices (AMD), Austin, TX, USA","institution_ids":["https://openalex.org/I1311921367"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.38,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.54522293,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"20","issue":null,"first_page":"303","last_page":"310"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10054","display_name":"Parallel Computing and Optimization Techniques","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1708","display_name":"Hardware and Architecture"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10054","display_name":"Parallel Computing and Optimization Techniques","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1708","display_name":"Hardware and Architecture"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10829","display_name":"Interconnection Networks and Systems","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11181","display_name":"Advanced Data Storage Technologies","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7084466218948364},{"id":"https://openalex.org/keywords/memory-hierarchy","display_name":"Memory hierarchy","score":0.6807072162628174},{"id":"https://openalex.org/keywords/digital-signal-processing","display_name":"Digital signal processing","score":0.6256873607635498},{"id":"https://openalex.org/keywords/computer-architecture","display_name":"Computer architecture","score":0.5663162469863892},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.542365550994873},{"id":"https://openalex.org/keywords/memory-management","display_name":"Memory management","score":0.4823684096336365},{"id":"https://openalex.org/keywords/memory-architecture","display_name":"Memory architecture","score":0.47430920600891113},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.4701445400714874},{"id":"https://openalex.org/keywords/flat-memory-model","display_name":"Flat memory model","score":0.4677937626838684},{"id":"https://openalex.org/keywords/semiconductor-memory","display_name":"Semiconductor memory","score":0.4408310055732727},{"id":"https://openalex.org/keywords/computer-hardware","display_name":"Computer hardware","score":0.35753270983695984},{"id":"https://openalex.org/keywords/parallel-computing","display_name":"Parallel computing","score":0.23623546957969666},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.13619887828826904},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.09553003311157227}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7084466218948364},{"id":"https://openalex.org/C2778100165","wikidata":"https://www.wikidata.org/wiki/Q1589327","display_name":"Memory hierarchy","level":3,"score":0.6807072162628174},{"id":"https://openalex.org/C84462506","wikidata":"https://www.wikidata.org/wiki/Q173142","display_name":"Digital signal processing","level":2,"score":0.6256873607635498},{"id":"https://openalex.org/C118524514","wikidata":"https://www.wikidata.org/wiki/Q173212","display_name":"Computer architecture","level":1,"score":0.5663162469863892},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.542365550994873},{"id":"https://openalex.org/C176649486","wikidata":"https://www.wikidata.org/wiki/Q2308807","display_name":"Memory management","level":3,"score":0.4823684096336365},{"id":"https://openalex.org/C2779602883","wikidata":"https://www.wikidata.org/wiki/Q15544750","display_name":"Memory architecture","level":2,"score":0.47430920600891113},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.4701445400714874},{"id":"https://openalex.org/C57863822","wikidata":"https://www.wikidata.org/wiki/Q905488","display_name":"Flat memory model","level":4,"score":0.4677937626838684},{"id":"https://openalex.org/C98986596","wikidata":"https://www.wikidata.org/wiki/Q1143031","display_name":"Semiconductor memory","level":2,"score":0.4408310055732727},{"id":"https://openalex.org/C9390403","wikidata":"https://www.wikidata.org/wiki/Q3966","display_name":"Computer hardware","level":1,"score":0.35753270983695984},{"id":"https://openalex.org/C173608175","wikidata":"https://www.wikidata.org/wiki/Q232661","display_name":"Parallel computing","level":1,"score":0.23623546957969666},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.13619887828826904},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.09553003311157227},{"id":"https://openalex.org/C115537543","wikidata":"https://www.wikidata.org/wiki/Q165596","display_name":"Cache","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/samos.2011.6045476","is_oa":false,"landing_page_url":"https://doi.org/10.1109/samos.2011.6045476","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 International Conference on Embedded Computer Systems: Architectures, Modeling and Simulation","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.8999999761581421}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":26,"referenced_works":["https://openalex.org/W205270008","https://openalex.org/W245914994","https://openalex.org/W1983096721","https://openalex.org/W2023264348","https://openalex.org/W2036853599","https://openalex.org/W2044206819","https://openalex.org/W2046574526","https://openalex.org/W2082499523","https://openalex.org/W2110895508","https://openalex.org/W2117285153","https://openalex.org/W2117816012","https://openalex.org/W2122636510","https://openalex.org/W2131029245","https://openalex.org/W2131413854","https://openalex.org/W2141736089","https://openalex.org/W2141973190","https://openalex.org/W2142671730","https://openalex.org/W2143807959","https://openalex.org/W2152958194","https://openalex.org/W2725179571","https://openalex.org/W3139689176","https://openalex.org/W4249006057","https://openalex.org/W4292169167","https://openalex.org/W6608275246","https://openalex.org/W6677504465","https://openalex.org/W6681089294"],"related_works":["https://openalex.org/W4312264564","https://openalex.org/W4248614727","https://openalex.org/W2043352873","https://openalex.org/W2296275612","https://openalex.org/W1500809736","https://openalex.org/W2074563599","https://openalex.org/W1575240748","https://openalex.org/W2140386982","https://openalex.org/W3048967625","https://openalex.org/W2561005478"],"abstract_inverted_index":{"Recently,":[0],"three-dimensional":[1],"integration":[2,32,56],"technology":[3,33,69],"has":[4],"allowed":[5],"researchers":[6],"and":[7,50,121],"designers":[8],"to":[9,17,94,104,117,123],"explore":[10],"novel":[11],"architectures":[12],"for":[13],"computing":[14],"systems.":[15],"Due":[16],"the":[18,48,68,119],"memory-intensive":[19],"nature":[20],"of":[21,53,65,85,130],"signal":[22],"processing":[23,41],"systems,":[24],"DSPs":[25],"can":[26,79],"greatly":[27],"benefit":[28],"from":[29],"3D":[30,54,76],"memory":[31,39,55,66,77,98,112],"realized":[34],"by":[35,60,82,90,127],"vertically":[36],"stacking":[37],"high-density":[38],"below":[40],"cores.":[42],"In":[43],"this":[44],"paper,":[45],"we":[46],"analyze":[47],"energy":[49,89,125],"performance":[51,81],"impacts":[52],"in":[57],"DSP":[58],"systems":[59],"exploring":[61],"a":[62,75,101,105],"wide":[63],"variety":[64],"configurations":[67],"enables.":[70],"Our":[71],"analysis":[72],"demonstrates":[73],"that":[74],"hierarchy":[78],"increase":[80],"an":[83,128],"average":[84,129],"20.6%":[86],"while":[87],"decreasing":[88,133],"6.7%":[91],"when":[92],"compared":[93],"our":[95],"baseline":[96],"2D":[97],"hierarchy,":[99],"with":[100],"processor":[102],"similar":[103],"Texas":[106],"Instrument":[107],"C67\u00d7":[108],"DSP.":[109],"This":[110],"proposed":[111],"architecture":[113],"also":[114],"allows":[115],"us":[116],"scale":[118],"voltage":[120],"frequency":[122],"decrease":[124],"consumption":[126],"23%":[131],"without":[132],"performance.":[134]},"counts_by_year":[{"year":2014,"cited_by_count":1},{"year":2013,"cited_by_count":1}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
