{"id":"https://openalex.org/W2177282259","doi":"https://doi.org/10.1109/sahcn.2015.7338325","title":"QU-RPL: Queue utilization based RPL for load balancing in large scale industrial applications","display_name":"QU-RPL: Queue utilization based RPL for load balancing in large scale industrial applications","publication_year":2015,"publication_date":"2015-06-01","ids":{"openalex":"https://openalex.org/W2177282259","doi":"https://doi.org/10.1109/sahcn.2015.7338325","mag":"2177282259"},"language":"en","primary_location":{"id":"doi:10.1109/sahcn.2015.7338325","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sahcn.2015.7338325","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 12th Annual IEEE International Conference on Sensing, Communication, and Networking (SECON)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5065781070","display_name":"Hyung\u2010Sin Kim","orcid":"https://orcid.org/0000-0001-8605-5077"},"institutions":[{"id":"https://openalex.org/I139264467","display_name":"Seoul National University","ror":"https://ror.org/04h9pn542","country_code":"KR","type":"education","lineage":["https://openalex.org/I139264467"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Hyung-Sin Kim","raw_affiliation_strings":["Department of Electrical Engineering, Seoul National University and INMC, Seoul, Republic of Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Seoul National University and INMC, Seoul, Republic of Korea","institution_ids":["https://openalex.org/I139264467"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5051076677","display_name":"Jeongyeup Paek","orcid":"https://orcid.org/0000-0001-5177-4936"},"institutions":[{"id":"https://openalex.org/I94588446","display_name":"Hongik University","ror":"https://ror.org/00egdv862","country_code":"KR","type":"education","lineage":["https://openalex.org/I94588446"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Jeongyeup Paek","raw_affiliation_strings":["Dept. of Computer Information Communication Engineering, Hongik University, Sejong, Republic of Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dept. of Computer Information Communication Engineering, Hongik University, Sejong, Republic of Korea","institution_ids":["https://openalex.org/I94588446"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5006997436","display_name":"Saewoong Bahk","orcid":null},"institutions":[{"id":"https://openalex.org/I139264467","display_name":"Seoul National University","ror":"https://ror.org/04h9pn542","country_code":"KR","type":"education","lineage":["https://openalex.org/I139264467"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Saewoong Bahk","raw_affiliation_strings":["Department of Electrical Engineering, Seoul National University and INMC, Seoul, Republic of Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Seoul National University and INMC, Seoul, Republic of Korea","institution_ids":["https://openalex.org/I139264467"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":9.2658,"has_fulltext":false,"cited_by_count":101,"citation_normalized_percentile":{"value":0.98868863,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":96,"max":100},"biblio":{"volume":null,"issue":null,"first_page":"265","last_page":"273"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10080","display_name":"Energy Efficient Wireless Sensor Networks","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10080","display_name":"Energy Efficient Wireless Sensor Networks","score":1.0,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10714","display_name":"Software-Defined Networks and 5G","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11392","display_name":"Energy Harvesting in Wireless Networks","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.7632739543914795},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7084614038467407},{"id":"https://openalex.org/keywords/testbed","display_name":"Testbed","score":0.612991988658905},{"id":"https://openalex.org/keywords/ipv6","display_name":"IPv6","score":0.5623049139976501},{"id":"https://openalex.org/keywords/load-balancing","display_name":"Load balancing (electrical power)","score":0.5199869275093079},{"id":"https://openalex.org/keywords/routing-protocol","display_name":"Routing protocol","score":0.5062138438224792},{"id":"https://openalex.org/keywords/queue","display_name":"Queue","score":0.5003290176391602},{"id":"https://openalex.org/keywords/network-packet","display_name":"Network packet","score":0.49927735328674316},{"id":"https://openalex.org/keywords/router","display_name":"Router","score":0.4284895658493042},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.3371928930282593},{"id":"https://openalex.org/keywords/the-internet","display_name":"The Internet","score":0.2764657735824585},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.24201437830924988}],"concepts":[{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.7632739543914795},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7084614038467407},{"id":"https://openalex.org/C31395832","wikidata":"https://www.wikidata.org/wiki/Q1318674","display_name":"Testbed","level":2,"score":0.612991988658905},{"id":"https://openalex.org/C84555802","wikidata":"https://www.wikidata.org/wiki/Q2551624","display_name":"IPv6","level":3,"score":0.5623049139976501},{"id":"https://openalex.org/C138959212","wikidata":"https://www.wikidata.org/wiki/Q1806783","display_name":"Load balancing (electrical power)","level":3,"score":0.5199869275093079},{"id":"https://openalex.org/C104954878","wikidata":"https://www.wikidata.org/wiki/Q1648707","display_name":"Routing protocol","level":3,"score":0.5062138438224792},{"id":"https://openalex.org/C160403385","wikidata":"https://www.wikidata.org/wiki/Q220543","display_name":"Queue","level":2,"score":0.5003290176391602},{"id":"https://openalex.org/C158379750","wikidata":"https://www.wikidata.org/wiki/Q214111","display_name":"Network packet","level":2,"score":0.49927735328674316},{"id":"https://openalex.org/C2775896111","wikidata":"https://www.wikidata.org/wiki/Q642560","display_name":"Router","level":2,"score":0.4284895658493042},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.3371928930282593},{"id":"https://openalex.org/C110875604","wikidata":"https://www.wikidata.org/wiki/Q75","display_name":"The Internet","level":2,"score":0.2764657735824585},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.24201437830924988},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C136764020","wikidata":"https://www.wikidata.org/wiki/Q466","display_name":"World Wide Web","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/sahcn.2015.7338325","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sahcn.2015.7338325","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 12th Annual IEEE International Conference on Sensing, Communication, and Networking (SECON)","raw_type":"proceedings-article"},{"id":"pmh:oai:s-space.snu.ac.kr:10371/203200","is_oa":false,"landing_page_url":"https://hdl.handle.net/10371/203200","pdf_url":null,"source":{"id":"https://openalex.org/S4306401345","display_name":"Seoul National University Open Repository (Seoul National University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I139264467","host_organization_name":"Seoul National University","host_organization_lineage":["https://openalex.org/I139264467"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Proceedings Paper"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.4699999988079071}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":41,"referenced_works":["https://openalex.org/W90345525","https://openalex.org/W205560478","https://openalex.org/W1965636790","https://openalex.org/W1974907922","https://openalex.org/W1991252512","https://openalex.org/W1997239185","https://openalex.org/W2013197574","https://openalex.org/W2020854838","https://openalex.org/W2027726514","https://openalex.org/W2033347526","https://openalex.org/W2050349806","https://openalex.org/W2058632086","https://openalex.org/W2067036994","https://openalex.org/W2068130807","https://openalex.org/W2081415566","https://openalex.org/W2102905508","https://openalex.org/W2111075016","https://openalex.org/W2116331532","https://openalex.org/W2117520883","https://openalex.org/W2122682296","https://openalex.org/W2125505252","https://openalex.org/W2130090523","https://openalex.org/W2154478511","https://openalex.org/W2169339036","https://openalex.org/W2232887944","https://openalex.org/W2269222209","https://openalex.org/W2281666703","https://openalex.org/W2291624348","https://openalex.org/W2303186826","https://openalex.org/W2325877089","https://openalex.org/W2520954874","https://openalex.org/W3024666046","https://openalex.org/W4230622395","https://openalex.org/W4245685877","https://openalex.org/W4248450945","https://openalex.org/W6608300349","https://openalex.org/W6653348385","https://openalex.org/W6665166143","https://openalex.org/W6693631785","https://openalex.org/W6726798673","https://openalex.org/W6811998686"],"related_works":["https://openalex.org/W2883256816","https://openalex.org/W2171408034","https://openalex.org/W3003320923","https://openalex.org/W2106140982","https://openalex.org/W2152313554","https://openalex.org/W2064303750","https://openalex.org/W4285042611","https://openalex.org/W1509300825","https://openalex.org/W2057135347","https://openalex.org/W2393445026"],"abstract_inverted_index":{"RPL":[0,36,104,125],"is":[1,140,177],"an":[2,165],"IPv6":[3,40],"routing":[4,108],"protocol":[5],"for":[6,142],"low-power":[7],"and":[8,29,32,59,76,96,185],"lossy":[9],"networks":[10],"(LLNs)":[11],"designed":[12,141],"to":[13,48,94,135,145,164,171],"meet":[14],"the":[15,49,52,73,136,151,182,187],"requirements":[16],"of":[17,21,51,54,61,79,86,107,154,203],"a":[18,97,118,200,204],"wide":[19],"range":[20],"LLN":[22,45,166,206],"applications":[23],"including":[24],"smart":[25],"grid":[26],"AMIs,":[27],"industrial":[28],"environmental":[30],"monitoring,":[31],"wireless":[33],"sensor":[34],"networks.":[35,67],"allows":[37],"bi-directional":[38],"end-to-end":[39,130],"communication":[41],"on":[42,199],"resource":[43],"constrained":[44],"devices,":[46],"leading":[47],"concept":[50],"Internet":[53],"Things":[55],"(IoT)":[56],"with":[57],"thousands":[58],"millions":[60],"devices":[62],"interconnected":[63],"through":[64,196],"multihop":[65,205],"mesh":[66],"In":[68],"this":[69,113,115],"paper,":[70],"we":[71,82],"investigate":[72],"load":[74,99,173],"balancing":[75,100,174],"congestion":[77],"problem":[78,101],"RPL.":[80,138],"Specifically,":[81],"show":[83],"that":[84,127],"most":[85],"packet":[87,131,188],"losses":[88,184],"under":[89],"heavy":[90],"traffic":[91],"are":[92],"due":[93],"congestion,":[95],"serious":[98],"exists":[102],"in":[103,105,180],"terms":[106],"parent":[109,148],"selection.":[110],"To":[111],"overcome":[112],"problem,":[114],"paper":[116],"proposes":[117],"simple":[119],"yet":[120],"effective":[121,179],"queue":[122,152,183],"utilization":[123,153],"based":[124],"(QU-RPL)":[126],"significantly":[128],"improves":[129],"delivery":[132,189],"performance":[133],"compared":[134],"standard":[137],"QU-RPL":[139,176],"each":[143],"node":[144,149],"select":[146],"its":[147,155,172],"considering":[150],"neighbor":[156],"nodes":[157],"as":[158,160],"well":[159],"their":[161],"hop":[162],"distances":[163],"border":[167],"router":[168],"(LBR).":[169],"Owing":[170],"capability,":[175],"very":[178],"lowering":[181],"increasing":[186],"ratio.":[190],"We":[191],"verify":[192],"all":[193],"our":[194],"findings":[195],"experimental":[197],"measurements":[198],"real":[201],"testbed":[202],"over":[207],"IEEE":[208],"802.15.4.":[209]},"counts_by_year":[{"year":2026,"cited_by_count":3},{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":7},{"year":2023,"cited_by_count":7},{"year":2022,"cited_by_count":7},{"year":2021,"cited_by_count":18},{"year":2020,"cited_by_count":10},{"year":2019,"cited_by_count":11},{"year":2018,"cited_by_count":12},{"year":2017,"cited_by_count":11},{"year":2016,"cited_by_count":8},{"year":2015,"cited_by_count":4}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
