{"id":"https://openalex.org/W4382204017","doi":"https://doi.org/10.1109/saci58269.2023.10158616","title":"Testing of 6-500 kV Cables in Polymer Pipes","display_name":"Testing of 6-500 kV Cables in Polymer Pipes","publication_year":2023,"publication_date":"2023-05-23","ids":{"openalex":"https://openalex.org/W4382204017","doi":"https://doi.org/10.1109/saci58269.2023.10158616"},"language":"en","primary_location":{"id":"doi:10.1109/saci58269.2023.10158616","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/saci58269.2023.10158616","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE 17th International Symposium on Applied Computational Intelligence and Informatics (SACI)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5082813429","display_name":"\u041c. \u041e. Dmitriev","orcid":"https://orcid.org/0000-0002-6211-4164"},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"M. Dmitriev","raw_affiliation_strings":["LLP &#x201C;PolymerEnergy&#x201D;,Technical department,Astana,Qazaqstan"],"affiliations":[{"raw_affiliation_string":"LLP &#x201C;PolymerEnergy&#x201D;,Technical department,Astana,Qazaqstan","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5036673393","display_name":"Gy\u00f6rgy Morva","orcid":null},"institutions":[{"id":"https://openalex.org/I2801419141","display_name":"Buda Health Center","ror":"https://ror.org/00yx04352","country_code":"HU","type":"healthcare","lineage":["https://openalex.org/I2801419141"]}],"countries":["HU"],"is_corresponding":false,"raw_author_name":"Gy\u00f6rgy Morva","raw_affiliation_strings":["&#x00D3;buda University,KVK Dept. of Power Systems,Budapest,Hungary"],"affiliations":[{"raw_affiliation_string":"&#x00D3;buda University,KVK Dept. of Power Systems,Budapest,Hungary","institution_ids":["https://openalex.org/I2801419141"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5027183998","display_name":"P Kadar","orcid":"https://orcid.org/0000-0001-5828-6417"},"institutions":[{"id":"https://openalex.org/I2801419141","display_name":"Buda Health Center","ror":"https://ror.org/00yx04352","country_code":"HU","type":"healthcare","lineage":["https://openalex.org/I2801419141"]}],"countries":["HU"],"is_corresponding":false,"raw_author_name":"P\u00e9ter K\u00e1d\u00e1r","raw_affiliation_strings":["&#x00D3;buda University,KVK Dept. of Power Systems,Budapest,Hungary"],"affiliations":[{"raw_affiliation_string":"&#x00D3;buda University,KVK Dept. of Power Systems,Budapest,Hungary","institution_ids":["https://openalex.org/I2801419141"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5082813429"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.2076,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.47111691,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"11","issue":null,"first_page":"000227","last_page":"000230"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.97079998254776,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.97079998254776,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.965399980545044,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12169","display_name":"Non-Destructive Testing Techniques","score":0.9243000149726868,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/polymer","display_name":"Polymer","score":0.5378763675689697},{"id":"https://openalex.org/keywords/line","display_name":"Line (geometry)","score":0.508167028427124},{"id":"https://openalex.org/keywords/laying","display_name":"Laying","score":0.4748803973197937},{"id":"https://openalex.org/keywords/excavation","display_name":"Excavation","score":0.4665842652320862},{"id":"https://openalex.org/keywords/direct-buried-cable","display_name":"Direct-buried cable","score":0.4589709937572479},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.4461720883846283},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3450419306755066},{"id":"https://openalex.org/keywords/structural-engineering","display_name":"Structural engineering","score":0.33591949939727783},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3252469301223755},{"id":"https://openalex.org/keywords/cable-harness","display_name":"Cable harness","score":0.30965352058410645},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.3048165440559387},{"id":"https://openalex.org/keywords/composite-material","display_name":"Composite material","score":0.28953802585601807},{"id":"https://openalex.org/keywords/geotechnical-engineering","display_name":"Geotechnical engineering","score":0.19267326593399048},{"id":"https://openalex.org/keywords/cable-gland","display_name":"Cable gland","score":0.17858219146728516}],"concepts":[{"id":"https://openalex.org/C521977710","wikidata":"https://www.wikidata.org/wiki/Q81163","display_name":"Polymer","level":2,"score":0.5378763675689697},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.508167028427124},{"id":"https://openalex.org/C2780812243","wikidata":"https://www.wikidata.org/wiki/Q6505583","display_name":"Laying","level":2,"score":0.4748803973197937},{"id":"https://openalex.org/C31858485","wikidata":"https://www.wikidata.org/wiki/Q959782","display_name":"Excavation","level":2,"score":0.4665842652320862},{"id":"https://openalex.org/C137802790","wikidata":"https://www.wikidata.org/wiki/Q5280219","display_name":"Direct-buried cable","level":5,"score":0.4589709937572479},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.4461720883846283},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3450419306755066},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.33591949939727783},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3252469301223755},{"id":"https://openalex.org/C180761244","wikidata":"https://www.wikidata.org/wiki/Q354262","display_name":"Cable harness","level":3,"score":0.30965352058410645},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3048165440559387},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.28953802585601807},{"id":"https://openalex.org/C187320778","wikidata":"https://www.wikidata.org/wiki/Q1349130","display_name":"Geotechnical engineering","level":1,"score":0.19267326593399048},{"id":"https://openalex.org/C110925319","wikidata":"https://www.wikidata.org/wiki/Q12855","display_name":"Cable gland","level":2,"score":0.17858219146728516},{"id":"https://openalex.org/C59399137","wikidata":"https://www.wikidata.org/wiki/Q1327423","display_name":"Cable theory","level":4,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/saci58269.2023.10158616","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/saci58269.2023.10158616","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2023 IEEE 17th International Symposium on Applied Computational Intelligence and Informatics (SACI)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W2556824413","https://openalex.org/W4366540014","https://openalex.org/W4382204017","https://openalex.org/W6729734814","https://openalex.org/W6853871356"],"related_works":["https://openalex.org/W2391263439","https://openalex.org/W2369600172","https://openalex.org/W2120456283","https://openalex.org/W4313429035","https://openalex.org/W2351832105","https://openalex.org/W2478952141","https://openalex.org/W2352929283","https://openalex.org/W2105336176","https://openalex.org/W2355781476","https://openalex.org/W2006801259"],"abstract_inverted_index":{"In":[0],"recent":[1],"years,":[2],"the":[3,21,53,58,64,71],"laying":[4],"of":[5,23,35,55,67],"6-500":[6],"kV":[7],"cable":[8,59],"lines":[9],"in":[10,57],"polymer":[11,42],"pipes":[12,43],"has":[13,40],"become":[14],"widespread.":[15],"This":[16],"solution":[17],"allows":[18],"to":[19,25,31,51],"minimize":[20],"amount":[22],"excavation,":[24],"cross":[26],"various":[27],"communications":[28],"and":[29,62],"barriers,":[30],"provide":[32],"mechanical":[33],"protection":[34],"cables.":[36],"However,":[37],"as":[38],"experience":[39],"shown,":[41],"have":[44],"a":[45],"significant":[46],"drawback":[47],"\u2013":[48],"they":[49],"prevent":[50],"identify":[52],"presence":[54],"defects":[56,69],"outer":[60],"sheath":[61],"determine":[63],"exact":[65],"location":[66],"these":[68],"along":[70],"line":[72],"route.":[73]},"counts_by_year":[{"year":2023,"cited_by_count":1}],"updated_date":"2025-12-24T23:09:58.560324","created_date":"2025-10-10T00:00:00"}
