{"id":"https://openalex.org/W2158063742","doi":"https://doi.org/10.1109/saci.2011.5873062","title":"Optimal control for a variable-speed wind turbine","display_name":"Optimal control for a variable-speed wind turbine","publication_year":2011,"publication_date":"2011-05-01","ids":{"openalex":"https://openalex.org/W2158063742","doi":"https://doi.org/10.1109/saci.2011.5873062","mag":"2158063742"},"language":"en","primary_location":{"id":"doi:10.1109/saci.2011.5873062","is_oa":false,"landing_page_url":"https://doi.org/10.1109/saci.2011.5873062","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 6th IEEE International Symposium on Applied Computational Intelligence and Informatics (SACI)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5006994320","display_name":"Cosmin Koch\u2010Ciobotaru","orcid":"https://orcid.org/0000-0002-8164-3635"},"institutions":[{"id":"https://openalex.org/I3122695212","display_name":"Polytechnic University of Timi\u015foara","ror":"https://ror.org/02v91gy68","country_code":"RO","type":"education","lineage":["https://openalex.org/I3122695212"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"Cosmin Koch-Ciobotaru","raw_affiliation_strings":["Department of Automation and Applied Informatics, Polytechnic University of Timisoara, Timisoara, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Automation and Applied Informatics, Polytechnic University of Timisoara, Timisoara, Romania","institution_ids":["https://openalex.org/I3122695212"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5007190253","display_name":"R. Boraci","orcid":null},"institutions":[{"id":"https://openalex.org/I3122695212","display_name":"Polytechnic University of Timi\u015foara","ror":"https://ror.org/02v91gy68","country_code":"RO","type":"education","lineage":["https://openalex.org/I3122695212"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"Radu Boraci","raw_affiliation_strings":["Department of Automation and Applied Informatics, Polytechnic University of Timisoara, Timisoara, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Automation and Applied Informatics, Polytechnic University of Timisoara, Timisoara, Romania","institution_ids":["https://openalex.org/I3122695212"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5016967605","display_name":"Octavian Pro\u0219tean","orcid":"https://orcid.org/0000-0002-0459-5916"},"institutions":[{"id":"https://openalex.org/I3122695212","display_name":"Polytechnic University of Timi\u015foara","ror":"https://ror.org/02v91gy68","country_code":"RO","type":"education","lineage":["https://openalex.org/I3122695212"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"Octavian Prostean","raw_affiliation_strings":["Department of Automation and Applied Informatics, Polytechnic University of Timisoara, Timisoara, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Automation and Applied Informatics, Polytechnic University of Timisoara, Timisoara, Romania","institution_ids":["https://openalex.org/I3122695212"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5011100331","display_name":"N. Budi\u015fan","orcid":null},"institutions":[{"id":"https://openalex.org/I3122695212","display_name":"Polytechnic University of Timi\u015foara","ror":"https://ror.org/02v91gy68","country_code":"RO","type":"education","lineage":["https://openalex.org/I3122695212"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"Nicolae Budisan","raw_affiliation_strings":["Department of Automation and Applied Informatics, Polytechnic University of Timisoara, Timisoara, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Automation and Applied Informatics, Polytechnic University of Timisoara, Timisoara, Romania","institution_ids":["https://openalex.org/I3122695212"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I3122695212"],"apc_list":null,"apc_paid":null,"fwci":0.895,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.74118936,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"541","last_page":"544"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9908999800682068,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9854999780654907,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/turbine","display_name":"Turbine","score":0.7349364757537842},{"id":"https://openalex.org/keywords/permanent-magnet-synchronous-generator","display_name":"Permanent magnet synchronous generator","score":0.6923925876617432},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.643723726272583},{"id":"https://openalex.org/keywords/rectifier","display_name":"Rectifier (neural networks)","score":0.6309545040130615},{"id":"https://openalex.org/keywords/wind-power","display_name":"Wind power","score":0.6178975105285645},{"id":"https://openalex.org/keywords/wind-speed","display_name":"Wind speed","score":0.5814746022224426},{"id":"https://openalex.org/keywords/maximum-power-principle","display_name":"Maximum power principle","score":0.5669434070587158},{"id":"https://openalex.org/keywords/power-optimizer","display_name":"Power optimizer","score":0.5605211853981018},{"id":"https://openalex.org/keywords/maximum-power-point-tracking","display_name":"Maximum power point tracking","score":0.5063377618789673},{"id":"https://openalex.org/keywords/matlab","display_name":"MATLAB","score":0.47810858488082886},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4506514072418213},{"id":"https://openalex.org/keywords/variable-speed-wind-turbine","display_name":"Variable speed wind turbine","score":0.44030192494392395},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4385012984275818},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.3877258896827698},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.3802376389503479},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.33631616830825806},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.3089436888694763},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.14750194549560547},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.13392218947410583},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.07581731677055359}],"concepts":[{"id":"https://openalex.org/C2778449969","wikidata":"https://www.wikidata.org/wiki/Q130760","display_name":"Turbine","level":2,"score":0.7349364757537842},{"id":"https://openalex.org/C201320609","wikidata":"https://www.wikidata.org/wiki/Q3274420","display_name":"Permanent magnet synchronous generator","level":3,"score":0.6923925876617432},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.643723726272583},{"id":"https://openalex.org/C50100734","wikidata":"https://www.wikidata.org/wiki/Q7303176","display_name":"Rectifier (neural networks)","level":5,"score":0.6309545040130615},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.6178975105285645},{"id":"https://openalex.org/C161067210","wikidata":"https://www.wikidata.org/wiki/Q1464943","display_name":"Wind speed","level":2,"score":0.5814746022224426},{"id":"https://openalex.org/C116615679","wikidata":"https://www.wikidata.org/wiki/Q6795908","display_name":"Maximum power principle","level":3,"score":0.5669434070587158},{"id":"https://openalex.org/C145180747","wikidata":"https://www.wikidata.org/wiki/Q7236587","display_name":"Power optimizer","level":5,"score":0.5605211853981018},{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.5063377618789673},{"id":"https://openalex.org/C2780365114","wikidata":"https://www.wikidata.org/wiki/Q169478","display_name":"MATLAB","level":2,"score":0.47810858488082886},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4506514072418213},{"id":"https://openalex.org/C2776336204","wikidata":"https://www.wikidata.org/wiki/Q17104528","display_name":"Variable speed wind turbine","level":4,"score":0.44030192494392395},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4385012984275818},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3877258896827698},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.3802376389503479},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.33631616830825806},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3089436888694763},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.14750194549560547},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.13392218947410583},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.07581731677055359},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C119857082","wikidata":"https://www.wikidata.org/wiki/Q2539","display_name":"Machine learning","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C147168706","wikidata":"https://www.wikidata.org/wiki/Q1457734","display_name":"Recurrent neural network","level":3,"score":0.0},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.0},{"id":"https://openalex.org/C50644808","wikidata":"https://www.wikidata.org/wiki/Q192776","display_name":"Artificial neural network","level":2,"score":0.0},{"id":"https://openalex.org/C86582703","wikidata":"https://www.wikidata.org/wiki/Q7617824","display_name":"Stochastic neural network","level":4,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/saci.2011.5873062","is_oa":false,"landing_page_url":"https://doi.org/10.1109/saci.2011.5873062","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 6th IEEE International Symposium on Applied Computational Intelligence and Informatics (SACI)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.9100000262260437,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320338080","display_name":"European Social Fund","ror":"https://ror.org/00k4n6c32"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":6,"referenced_works":["https://openalex.org/W1974032452","https://openalex.org/W2083615551","https://openalex.org/W2103991106","https://openalex.org/W2121262976","https://openalex.org/W2162448500","https://openalex.org/W2172211216"],"related_works":["https://openalex.org/W2790237748","https://openalex.org/W2547980553","https://openalex.org/W2061972042","https://openalex.org/W3119066623","https://openalex.org/W2358703277","https://openalex.org/W2744378053","https://openalex.org/W2913523512","https://openalex.org/W4212890068","https://openalex.org/W2740085213","https://openalex.org/W2156301706"],"abstract_inverted_index":{"The":[0,23,72],"paper":[1],"presents":[2],"a":[3,7,30,36,40,49,52],"control":[4,73],"strategy":[5,56],"for":[6],"wind":[8,21,60,70],"energy":[9],"conversion":[10],"system":[11,27],"(WECS)":[12],"which":[13,44],"tracks":[14],"the":[15,20,26,46,58,64,69,81],"maximum":[16],"power":[17],"point":[18],"of":[19,25,29,68],"turbine.":[22,71],"topology":[24],"consists":[28],"permanent":[31],"magnet":[32],"synchronous":[33],"generator":[34],"(PMSG),":[35],"diode":[37],"bridge":[38],"rectifier,":[39],"hybrid":[41],"dc-dc":[42],"converter":[43],"lowers":[45],"dc":[47],"voltage,":[48],"supercapacitor":[50],"and":[51,62,80,85],"battery":[53],"charger.":[54],"This":[55],"uses":[57],"measured":[59],"speed":[61,67],"imposes":[63],"optimal":[65],"rotation":[66],"method":[74],"is":[75],"simulated":[76],"in":[77],"Matlab/":[78],"Simulink":[79],"results":[82],"are":[83],"presented":[84],"discussed.":[86]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2012,"cited_by_count":2}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
