{"id":"https://openalex.org/W2146209516","doi":"https://doi.org/10.1109/robot.2008.4543383","title":"A novel method for in-situ calibration of a 2-dof force platform for tremor detection in small-sized animal models","display_name":"A novel method for in-situ calibration of a 2-dof force platform for tremor detection in small-sized animal models","publication_year":2008,"publication_date":"2008-05-01","ids":{"openalex":"https://openalex.org/W2146209516","doi":"https://doi.org/10.1109/robot.2008.4543383","mag":"2146209516"},"language":"en","primary_location":{"id":"doi:10.1109/robot.2008.4543383","is_oa":false,"landing_page_url":"https://doi.org/10.1109/robot.2008.4543383","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2008 IEEE International Conference on Robotics and Automation","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5022514554","display_name":"G. Cavallo","orcid":null},"institutions":[{"id":"https://openalex.org/I155125353","display_name":"Universit\u00e0 Campus Bio-Medico","ror":"https://ror.org/04gqx4x78","country_code":"IT","type":"education","lineage":["https://openalex.org/I155125353"]}],"countries":["IT"],"is_corresponding":true,"raw_author_name":"Giuseppe Cavallo","raw_affiliation_strings":["Biomedical Robotics & Biomicrosystem lab, Universita Campus Bio Medico Di Roma, Italy","Biomed. Robot. & Biomicrosystem Lab., Univ. Campus Bio-Medico of Rome, Rome"],"affiliations":[{"raw_affiliation_string":"Biomedical Robotics & Biomicrosystem lab, Universita Campus Bio Medico Di Roma, Italy","institution_ids":["https://openalex.org/I155125353"]},{"raw_affiliation_string":"Biomed. Robot. & Biomicrosystem Lab., Univ. Campus Bio-Medico of Rome, Rome","institution_ids":["https://openalex.org/I155125353"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5079258091","display_name":"Domenico Campolo","orcid":"https://orcid.org/0000-0001-6930-0413"},"institutions":[{"id":"https://openalex.org/I155125353","display_name":"Universit\u00e0 Campus Bio-Medico","ror":"https://ror.org/04gqx4x78","country_code":"IT","type":"education","lineage":["https://openalex.org/I155125353"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Domenico Campolo","raw_affiliation_strings":["Biomedical Robotics & Biomicrosystem lab, Universita Campus Bio Medico Di Roma, Italy","Biomed. Robot. & Biomicrosystem Lab., Univ. Campus Bio-Medico of Rome, Rome"],"affiliations":[{"raw_affiliation_string":"Biomedical Robotics & Biomicrosystem lab, Universita Campus Bio Medico Di Roma, Italy","institution_ids":["https://openalex.org/I155125353"]},{"raw_affiliation_string":"Biomed. Robot. & Biomicrosystem Lab., Univ. Campus Bio-Medico of Rome, Rome","institution_ids":["https://openalex.org/I155125353"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5097993334","display_name":"Giuseppe Fogliani","orcid":null},"institutions":[{"id":"https://openalex.org/I155125353","display_name":"Universit\u00e0 Campus Bio-Medico","ror":"https://ror.org/04gqx4x78","country_code":"IT","type":"education","lineage":["https://openalex.org/I155125353"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Giuseppe Fogliani","raw_affiliation_strings":["Biomedical Robotics & Biomicrosystem lab, Universita Campus Bio Medico Di Roma, Italy","Biomed. Robot. & Biomicrosystem Lab., Univ. Campus Bio-Medico of Rome, Rome"],"affiliations":[{"raw_affiliation_string":"Biomedical Robotics & Biomicrosystem lab, Universita Campus Bio Medico Di Roma, Italy","institution_ids":["https://openalex.org/I155125353"]},{"raw_affiliation_string":"Biomed. Robot. & Biomicrosystem Lab., Univ. Campus Bio-Medico of Rome, Rome","institution_ids":["https://openalex.org/I155125353"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5062776728","display_name":"Eugenio Guglielmelli","orcid":"https://orcid.org/0000-0001-8258-6073"},"institutions":[{"id":"https://openalex.org/I155125353","display_name":"Universit\u00e0 Campus Bio-Medico","ror":"https://ror.org/04gqx4x78","country_code":"IT","type":"education","lineage":["https://openalex.org/I155125353"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Eugenio Guglielmelli","raw_affiliation_strings":["Biomedical Robotics & Biomicrosystem lab, Universita Campus Bio Medico Di Roma, Italy","Biomed. Robot. & Biomicrosystem Lab., Univ. Campus Bio-Medico of Rome, Rome"],"affiliations":[{"raw_affiliation_string":"Biomedical Robotics & Biomicrosystem lab, Universita Campus Bio Medico Di Roma, Italy","institution_ids":["https://openalex.org/I155125353"]},{"raw_affiliation_string":"Biomed. Robot. & Biomicrosystem Lab., Univ. Campus Bio-Medico of Rome, Rome","institution_ids":["https://openalex.org/I155125353"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5022514554"],"corresponding_institution_ids":["https://openalex.org/I155125353"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.20190576,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"20","issue":null,"first_page":"1301","last_page":"1305"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10919","display_name":"Neurological disorders and treatments","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2728","display_name":"Neurology"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10919","display_name":"Neurological disorders and treatments","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2728","display_name":"Neurology"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11601","display_name":"Neuroscience and Neural Engineering","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2804","display_name":"Cellular and Molecular Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},{"id":"https://openalex.org/T10077","display_name":"Neuroscience and Neuropharmacology Research","score":0.9889000058174133,"subfield":{"id":"https://openalex.org/subfields/2804","display_name":"Cellular and Molecular Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.7788568735122681},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7337129712104797},{"id":"https://openalex.org/keywords/session","display_name":"Session (web analytics)","score":0.7042425870895386},{"id":"https://openalex.org/keywords/mechatronics","display_name":"Mechatronics","score":0.6765543818473816},{"id":"https://openalex.org/keywords/accelerometer","display_name":"Accelerometer","score":0.5503005981445312},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.4444442093372345},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.4082813858985901},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.3052467703819275},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.19081264734268188}],"concepts":[{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.7788568735122681},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7337129712104797},{"id":"https://openalex.org/C2779182362","wikidata":"https://www.wikidata.org/wiki/Q17126187","display_name":"Session (web analytics)","level":2,"score":0.7042425870895386},{"id":"https://openalex.org/C28704281","wikidata":"https://www.wikidata.org/wiki/Q180165","display_name":"Mechatronics","level":2,"score":0.6765543818473816},{"id":"https://openalex.org/C89805583","wikidata":"https://www.wikidata.org/wiki/Q192940","display_name":"Accelerometer","level":2,"score":0.5503005981445312},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.4444442093372345},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.4082813858985901},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.3052467703819275},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.19081264734268188},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C136764020","wikidata":"https://www.wikidata.org/wiki/Q466","display_name":"World Wide Web","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/robot.2008.4543383","is_oa":false,"landing_page_url":"https://doi.org/10.1109/robot.2008.4543383","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2008 IEEE International Conference on Robotics and Automation","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":19,"referenced_works":["https://openalex.org/W581348670","https://openalex.org/W1480965550","https://openalex.org/W1970325912","https://openalex.org/W1991618648","https://openalex.org/W1991959042","https://openalex.org/W1994092914","https://openalex.org/W2021758047","https://openalex.org/W2025506086","https://openalex.org/W2030052367","https://openalex.org/W2044117249","https://openalex.org/W2062567576","https://openalex.org/W2067302859","https://openalex.org/W2088963056","https://openalex.org/W2097918378","https://openalex.org/W2099856807","https://openalex.org/W2125437920","https://openalex.org/W2181653421","https://openalex.org/W2336349155","https://openalex.org/W6703547887"],"related_works":["https://openalex.org/W2554858923","https://openalex.org/W2356216756","https://openalex.org/W2964738388","https://openalex.org/W583659016","https://openalex.org/W2160983418","https://openalex.org/W1990044206","https://openalex.org/W21274994","https://openalex.org/W2153683994","https://openalex.org/W3005073981","https://openalex.org/W4231864133"],"abstract_inverted_index":{"Tremor":[0],"analysis":[1,31],"in":[2],"human":[3,16],"or":[4],"animal":[5],"model":[6],"plays":[7],"a":[8,85,95],"fundamental":[9],"role":[10],"for":[11,26,37],"understanding":[12],"the":[13,41,74,114,133,138],"physiopathology":[14],"of":[15,34,43,47,58,73,117,137],"disorders":[17],"and":[18,28,52,67,103,120,129],"to":[19,39,54,88,131],"test":[20],"new":[21,96],"pharmacological":[22],"treatments.":[23],"Mechatronic":[24],"systems":[25],"automatic":[27],"quantitative":[29],"behavioural":[30],"are":[32,50,127],"now":[33],"current":[35],"use":[36,116],"neuroscientists":[38],"improve":[40],"results":[42],"their":[44],"research.":[45],"Most":[46],"these":[48],"devices":[49],"portable":[51],"need":[53,105],"be":[55,78,89],"used":[56],"out":[57],"engineering":[59],"labs":[60],"by":[61],"personnel":[62],"with":[63,94],"no":[64],"technical":[65],"expertise":[66],"without":[68],"specific":[69],"equipment.":[70],"The":[71,124],"calibration":[72,97,135],"devices,":[75],"that":[76,99],"should":[77],"performed":[79],"before":[80],"each":[81],"experimental":[82],"session,":[83],"is":[84,100,111],"typical":[86],"issue":[87],"faced.":[90],"This":[91],"paper":[92],"deals":[93],"method":[98],"fast,":[101],"simple":[102],"doesn't":[104],"other":[106],"external":[107],"measurement":[108],"systems.":[109],"It":[110],"based":[112],"on":[113],"parallel":[115],"an":[118,121],"accelerometer":[119],"optical":[122],"sensor.":[123],"two":[125],"signals":[126],"processed":[128],"compared":[130],"obtain":[132],"final":[134],"curve":[136],"device.":[139]},"counts_by_year":[{"year":2013,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
