{"id":"https://openalex.org/W2507865173","doi":"https://doi.org/10.1109/pscc.2016.7540874","title":"Sensitivity of voltage sags to network failure rate improvement","display_name":"Sensitivity of voltage sags to network failure rate improvement","publication_year":2016,"publication_date":"2016-06-01","ids":{"openalex":"https://openalex.org/W2507865173","doi":"https://doi.org/10.1109/pscc.2016.7540874","mag":"2507865173"},"language":"en","primary_location":{"id":"doi:10.1109/pscc.2016.7540874","is_oa":false,"landing_page_url":"https://doi.org/10.1109/pscc.2016.7540874","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 Power Systems Computation Conference (PSCC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101730416","display_name":"Andr\u00e9 dos Santos","orcid":"https://orcid.org/0000-0001-5601-7117"},"institutions":[{"id":"https://openalex.org/I4210138867","display_name":"Redes Energ\u00e9ticas Nacionais (Portugal)","ror":"https://ror.org/03qgxnq88","country_code":"PT","type":"company","lineage":["https://openalex.org/I4210138867"]},{"id":"https://openalex.org/I203847022","display_name":"Instituto Polit\u00e9cnico de Lisboa","ror":"https://ror.org/04ea70f07","country_code":"PT","type":"education","lineage":["https://openalex.org/I203847022"]},{"id":"https://openalex.org/I141596103","display_name":"University of Lisbon","ror":"https://ror.org/01c27hj86","country_code":"PT","type":"education","lineage":["https://openalex.org/I141596103"]}],"countries":["PT"],"is_corresponding":true,"raw_author_name":"Andre dos Santos","raw_affiliation_strings":["Instituto Superior T\u00e9cnico, Universidade de Lisboa, Lisboa, Portugal","Rede El\u00e9ctrica Nacional S.A., Sacav\u00e9m, Portugal"],"affiliations":[{"raw_affiliation_string":"Instituto Superior T\u00e9cnico, Universidade de Lisboa, Lisboa, Portugal","institution_ids":["https://openalex.org/I203847022","https://openalex.org/I141596103"]},{"raw_affiliation_string":"Rede El\u00e9ctrica Nacional S.A., Sacav\u00e9m, Portugal","institution_ids":["https://openalex.org/I4210138867"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5038977484","display_name":"Maria Teresa Correia de Barros","orcid":"https://orcid.org/0000-0003-2494-5511"},"institutions":[{"id":"https://openalex.org/I203847022","display_name":"Instituto Polit\u00e9cnico de Lisboa","ror":"https://ror.org/04ea70f07","country_code":"PT","type":"education","lineage":["https://openalex.org/I203847022"]},{"id":"https://openalex.org/I141596103","display_name":"University of Lisbon","ror":"https://ror.org/01c27hj86","country_code":"PT","type":"education","lineage":["https://openalex.org/I141596103"]}],"countries":["PT"],"is_corresponding":false,"raw_author_name":"M.T. Correia de Barros","raw_affiliation_strings":["Instituto Superior T\u00e9cnico, Universidade de Lisboa, Lisboa, Portugal","Instituto Superior T\u00e9cnico \u2013 Universidade de Lisboa, Portugal"],"affiliations":[{"raw_affiliation_string":"Instituto Superior T\u00e9cnico, Universidade de Lisboa, Lisboa, Portugal","institution_ids":["https://openalex.org/I203847022","https://openalex.org/I141596103"]},{"raw_affiliation_string":"Instituto Superior T\u00e9cnico \u2013 Universidade de Lisboa, Portugal","institution_ids":["https://openalex.org/I203847022","https://openalex.org/I141596103"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5101730416"],"corresponding_institution_ids":["https://openalex.org/I141596103","https://openalex.org/I203847022","https://openalex.org/I4210138867"],"apc_list":null,"apc_paid":null,"fwci":0.3675,"has_fulltext":false,"cited_by_count":6,"citation_normalized_percentile":{"value":0.65434572,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":"pas 98","issue":null,"first_page":"1","last_page":"7"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.7643157243728638},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.5581851601600647},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.5096290111541748},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4650605320930481},{"id":"https://openalex.org/keywords/failure-rate","display_name":"Failure rate","score":0.42353928089141846},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.20775353908538818},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.18082726001739502},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.14689293503761292}],"concepts":[{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.7643157243728638},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.5581851601600647},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5096290111541748},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4650605320930481},{"id":"https://openalex.org/C163164238","wikidata":"https://www.wikidata.org/wiki/Q2737027","display_name":"Failure rate","level":2,"score":0.42353928089141846},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.20775353908538818},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.18082726001739502},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.14689293503761292}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/pscc.2016.7540874","is_oa":false,"landing_page_url":"https://doi.org/10.1109/pscc.2016.7540874","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 Power Systems Computation Conference (PSCC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":22,"referenced_works":["https://openalex.org/W313200271","https://openalex.org/W1004116146","https://openalex.org/W1603261253","https://openalex.org/W1990797570","https://openalex.org/W2056636551","https://openalex.org/W2065891997","https://openalex.org/W2072749823","https://openalex.org/W2101006151","https://openalex.org/W2101879350","https://openalex.org/W2117756216","https://openalex.org/W2143068257","https://openalex.org/W2149021281","https://openalex.org/W2156407331","https://openalex.org/W2280939974","https://openalex.org/W2497042780","https://openalex.org/W2547155816","https://openalex.org/W3022831370","https://openalex.org/W4207054975","https://openalex.org/W4238625500","https://openalex.org/W6635974437","https://openalex.org/W6675271148","https://openalex.org/W6681367592"],"related_works":["https://openalex.org/W2372318178","https://openalex.org/W3209466718","https://openalex.org/W2337334590","https://openalex.org/W3216201951","https://openalex.org/W1530507059","https://openalex.org/W2524718329","https://openalex.org/W2355543518","https://openalex.org/W2267274201","https://openalex.org/W2889865234","https://openalex.org/W3168522962"],"abstract_inverted_index":{"In":[0],"this":[1],"paper,":[2],"a":[3,115],"stochastic":[4,60],"approach":[5],"for":[6,121,132],"predicting":[7],"voltage":[8,27,45,98],"sags":[9],"is":[10,39,51,86,109,119,128],"applied.":[11],"The":[12,48,94],"methodology,":[13],"developed":[14,49],"by":[15,23,30],"the":[16,59,69,89,97,104,126,143,152],"authors,":[17],"allows":[18,140],"to":[19,41,103,113,141],"characterize":[20],"network":[21,133,148],"sites":[22],"time":[24],"series":[25],"of":[26,62,72,75,96],"sags,":[28],"described":[29],"amplitude,":[31],"duration":[32],"and":[33,57,78,137],"type.":[34],"A":[35],"responsibility":[36],"sharing":[37],"curve":[38],"used":[40,120],"establish":[42,114],"an":[43,129],"adequate":[44],"sag":[46,99],"index.":[47],"methodology":[50,127],"based":[52],"on":[53],"Monte":[54],"Carlo":[55],"simulation":[56],"considers":[58],"nature":[61,71],"power":[63],"system":[64],"faults,":[65],"as":[66,68],"well":[67],"probabilistic":[70],"successful":[73],"operation":[74,136],"transmission":[76,105,153],"line":[77],"busbar":[79],"primary":[80],"protection":[81],"systems.":[82],"An":[83],"application":[84],"example":[85],"presented,":[87],"considering":[88],"IEEE":[90],"Reliability":[91],"Test":[92],"System.":[93],"sensitivity":[95],"index":[100],"with":[101],"regard":[102],"lines":[106,154],"failure":[107,155],"rate":[108],"assessed.":[110],"Results":[111],"allow":[112],"linear":[116],"dependence,":[117],"which":[118],"site":[122],"characterization,":[123],"showing":[124],"that":[125],"important":[130],"tool":[131],"planning,":[134],"design,":[135],"maintenance.":[138],"It":[139],"quantify":[142],"benefits":[144],"obtained,":[145],"at":[146],"each":[147],"site,":[149],"from":[150],"reducing":[151],"rate.":[156]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":1},{"year":2016,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
