{"id":"https://openalex.org/W1987735645","doi":"https://doi.org/10.1109/pimrcw.2013.6707826","title":"QoS-aware user association based on cell zooming for energy efficiency in cellular networks","display_name":"QoS-aware user association based on cell zooming for energy efficiency in cellular networks","publication_year":2013,"publication_date":"2013-09-01","ids":{"openalex":"https://openalex.org/W1987735645","doi":"https://doi.org/10.1109/pimrcw.2013.6707826","mag":"1987735645"},"language":"en","primary_location":{"id":"doi:10.1109/pimrcw.2013.6707826","is_oa":false,"landing_page_url":"https://doi.org/10.1109/pimrcw.2013.6707826","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 IEEE 24th International Symposium on Personal, Indoor and Mobile Radio Communications (PIMRC Workshops)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5014860375","display_name":"Yutao Zhu","orcid":"https://orcid.org/0000-0003-1098-9150"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Yutao Zhu","raw_affiliation_strings":["Beijing Key Laboratory of Network System Architecture and Convergence, Beijing, China","Beijing Key Lab. of Network Syst. Archit. & Convergence, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Beijing Key Laboratory of Network System Architecture and Convergence, Beijing, China","institution_ids":[]},{"raw_affiliation_string":"Beijing Key Lab. of Network Syst. Archit. & Convergence, Beijing, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5063100275","display_name":"Tian Kang","orcid":"https://orcid.org/0000-0001-8550-4037"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Tian Kang","raw_affiliation_strings":["Beijing Key Laboratory of Network System Architecture and Convergence, Beijing, China","Beijing Key Lab. of Network Syst. Archit. & Convergence, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Beijing Key Laboratory of Network System Architecture and Convergence, Beijing, China","institution_ids":[]},{"raw_affiliation_string":"Beijing Key Lab. of Network Syst. Archit. & Convergence, Beijing, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5032943024","display_name":"Tiankui Zhang","orcid":"https://orcid.org/0000-0002-6953-847X"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Tiankui Zhang","raw_affiliation_strings":["Beijing Key Laboratory of Network System Architecture and Convergence, Beijing, China","Beijing Key Lab. of Network Syst. Archit. & Convergence, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Beijing Key Laboratory of Network System Architecture and Convergence, Beijing, China","institution_ids":[]},{"raw_affiliation_string":"Beijing Key Lab. of Network Syst. Archit. & Convergence, Beijing, China","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5074266087","display_name":"Zhimin Zeng","orcid":"https://orcid.org/0000-0003-0959-3044"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Zhimin Zeng","raw_affiliation_strings":["Beijing Key Laboratory of Network System Architecture and Convergence, Beijing, China","Beijing Key Lab. of Network Syst. Archit. & Convergence, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Beijing Key Laboratory of Network System Architecture and Convergence, Beijing, China","institution_ids":[]},{"raw_affiliation_string":"Beijing Key Lab. of Network Syst. Archit. & Convergence, Beijing, China","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":4.4583,"has_fulltext":false,"cited_by_count":24,"citation_normalized_percentile":{"value":0.95452191,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"6","last_page":"10"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10148","display_name":"Advanced MIMO Systems Optimization","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10148","display_name":"Advanced MIMO Systems Optimization","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10796","display_name":"Cooperative Communication and Network Coding","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11409","display_name":"Advanced Wireless Network Optimization","score":0.9987000226974487,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.8040745258331299},{"id":"https://openalex.org/keywords/quality-of-service","display_name":"Quality of service","score":0.8028900623321533},{"id":"https://openalex.org/keywords/sleep-mode","display_name":"Sleep mode","score":0.7529028654098511},{"id":"https://openalex.org/keywords/zoom","display_name":"Zoom","score":0.7095215320587158},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.6433067321777344},{"id":"https://openalex.org/keywords/heuristic","display_name":"Heuristic","score":0.5278603434562683},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.522796094417572},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.4958063066005707},{"id":"https://openalex.org/keywords/association","display_name":"Association (psychology)","score":0.44790196418762207},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.4404431879520416},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.37353143095970154},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.32634294033050537},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.08415722846984863},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.08287712931632996},{"id":"https://openalex.org/keywords/power-consumption","display_name":"Power consumption","score":0.07655587792396545},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.06441232562065125},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.06345018744468689}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.8040745258331299},{"id":"https://openalex.org/C5119721","wikidata":"https://www.wikidata.org/wiki/Q220501","display_name":"Quality of service","level":2,"score":0.8028900623321533},{"id":"https://openalex.org/C57149124","wikidata":"https://www.wikidata.org/wiki/Q587346","display_name":"Sleep mode","level":4,"score":0.7529028654098511},{"id":"https://openalex.org/C124913957","wikidata":"https://www.wikidata.org/wiki/Q1232548","display_name":"Zoom","level":3,"score":0.7095215320587158},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.6433067321777344},{"id":"https://openalex.org/C173801870","wikidata":"https://www.wikidata.org/wiki/Q201413","display_name":"Heuristic","level":2,"score":0.5278603434562683},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.522796094417572},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.4958063066005707},{"id":"https://openalex.org/C142853389","wikidata":"https://www.wikidata.org/wiki/Q744778","display_name":"Association (psychology)","level":2,"score":0.44790196418762207},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.4404431879520416},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.37353143095970154},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.32634294033050537},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.08415722846984863},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.08287712931632996},{"id":"https://openalex.org/C2984118289","wikidata":"https://www.wikidata.org/wiki/Q29954","display_name":"Power consumption","level":3,"score":0.07655587792396545},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.06441232562065125},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.06345018744468689},{"id":"https://openalex.org/C138885662","wikidata":"https://www.wikidata.org/wiki/Q5891","display_name":"Philosophy","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C78762247","wikidata":"https://www.wikidata.org/wiki/Q1273174","display_name":"Petroleum engineering","level":1,"score":0.0},{"id":"https://openalex.org/C111472728","wikidata":"https://www.wikidata.org/wiki/Q9471","display_name":"Epistemology","level":1,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C15336307","wikidata":"https://www.wikidata.org/wiki/Q1766051","display_name":"Lens (geology)","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/pimrcw.2013.6707826","is_oa":false,"landing_page_url":"https://doi.org/10.1109/pimrcw.2013.6707826","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 IEEE 24th International Symposium on Personal, Indoor and Mobile Radio Communications (PIMRC Workshops)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.9100000262260437,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W186536777","https://openalex.org/W1509579524","https://openalex.org/W1549593089","https://openalex.org/W2080747748","https://openalex.org/W2090180173","https://openalex.org/W2099295294","https://openalex.org/W2104998725","https://openalex.org/W2129733867","https://openalex.org/W2131414071","https://openalex.org/W2144239375","https://openalex.org/W2148349974","https://openalex.org/W2151062451","https://openalex.org/W2168165599","https://openalex.org/W2788355865","https://openalex.org/W6630596368","https://openalex.org/W6632792663"],"related_works":["https://openalex.org/W2056658160","https://openalex.org/W2903229902","https://openalex.org/W1549593089","https://openalex.org/W2906501616","https://openalex.org/W4316660971","https://openalex.org/W3035209734","https://openalex.org/W1917249301","https://openalex.org/W2113162709","https://openalex.org/W2564142622","https://openalex.org/W3037488035"],"abstract_inverted_index":{"In":[0,43,71],"cellular":[1],"networks,":[2],"cell":[3,49,66],"zooming":[4],"with":[5,23],"the":[6,9,34,41,48,65,72,76,85,95,116,132,142,150],"variation":[7],"of":[8,16,55,84,90],"traffic":[10,25,152],"load":[11,26],"is":[12,92,107],"considered":[13],"as":[14],"one":[15],"promising":[17],"technologies":[18],"for":[19,68,125],"energy":[20,69,82,126,138,143],"saving.":[21,70,127],"Cells":[22],"less":[24],"can":[27,121,135],"be":[28,122],"turned":[29,123],"into":[30],"sleep":[31],"mode":[32],"and":[33,81,99,114,140],"other":[35],"cells":[36,117],"zoom":[37],"in":[38],"to":[39,63,109],"ensure":[40],"coverage.":[42],"this":[44,111],"paper,":[45],"based":[46],"on":[47],"zooming,":[50],"we":[51,74],"propose":[52],"a":[53],"quality":[54],"service":[56],"(QoS)":[57],"aware":[58],"user":[59,100],"association":[60,67,101],"scheme":[61],"(UAS)":[62],"reconfigure":[64],"UAS,":[73],"consider":[75],"tradeoff":[77],"between":[78],"QoS":[79],"guarantee":[80],"saving":[83],"networks.":[86],"The":[87],"optimization":[88,112],"problem":[89],"UAS":[91,134],"derived":[93],"from":[94],"network":[96],"weight":[97],"matrix":[98],"matrix.":[102],"A":[103],"heuristic":[104],"iteration":[105],"algorithm":[106],"provided":[108],"solve":[110],"problem,":[113],"then":[115],"without":[118,145],"associated":[119],"users":[120],"off":[124],"Simulation":[128],"results":[129],"show":[130],"that":[131],"proposed":[133],"significantly":[136],"reduce":[137],"consumption":[139],"improve":[141],"efficiency":[144],"degrading":[146],"QoS,":[147],"especially":[148],"under":[149],"low":[151],"load.":[153]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":3},{"year":2018,"cited_by_count":6},{"year":2016,"cited_by_count":4},{"year":2015,"cited_by_count":4},{"year":2014,"cited_by_count":3}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
