{"id":"https://openalex.org/W4417282674","doi":"https://doi.org/10.1109/pimrc62392.2025.11275142","title":"A Battery Degradation Model for Cost-Optimized PV-BESS Design in Telecom Base Stations","display_name":"A Battery Degradation Model for Cost-Optimized PV-BESS Design in Telecom Base Stations","publication_year":2025,"publication_date":"2025-09-01","ids":{"openalex":"https://openalex.org/W4417282674","doi":"https://doi.org/10.1109/pimrc62392.2025.11275142"},"language":null,"primary_location":{"id":"doi:10.1109/pimrc62392.2025.11275142","is_oa":false,"landing_page_url":"https://doi.org/10.1109/pimrc62392.2025.11275142","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE 36th International Symposium on Personal, Indoor and Mobile Radio Communications (PIMRC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5004090870","display_name":"Mohammad Reza Akbari Jokar","orcid":"https://orcid.org/0000-0002-0215-6805"},"institutions":[{"id":"https://openalex.org/I177477856","display_name":"Polytechnic University of Turin","ror":"https://ror.org/00bgk9508","country_code":"IT","type":"education","lineage":["https://openalex.org/I177477856"]}],"countries":["IT"],"is_corresponding":true,"raw_author_name":"Mohammad Reza Jokar","raw_affiliation_strings":["Politecnico di Torino,Italy"],"affiliations":[{"raw_affiliation_string":"Politecnico di Torino,Italy","institution_ids":["https://openalex.org/I177477856"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5065722419","display_name":"Michela Meo","orcid":"https://orcid.org/0000-0001-7403-6266"},"institutions":[{"id":"https://openalex.org/I177477856","display_name":"Polytechnic University of Turin","ror":"https://ror.org/00bgk9508","country_code":"IT","type":"education","lineage":["https://openalex.org/I177477856"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Michela Meo","raw_affiliation_strings":["Politecnico di Torino,Italy"],"affiliations":[{"raw_affiliation_string":"Politecnico di Torino,Italy","institution_ids":["https://openalex.org/I177477856"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5030052724","display_name":"Greta Vallero","orcid":"https://orcid.org/0000-0002-6420-231X"},"institutions":[{"id":"https://openalex.org/I177477856","display_name":"Polytechnic University of Turin","ror":"https://ror.org/00bgk9508","country_code":"IT","type":"education","lineage":["https://openalex.org/I177477856"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Greta Vallero","raw_affiliation_strings":["Politecnico di Torino,Italy"],"affiliations":[{"raw_affiliation_string":"Politecnico di Torino,Italy","institution_ids":["https://openalex.org/I177477856"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5004796693","display_name":"Daniela Renga","orcid":"https://orcid.org/0000-0001-6747-3919"},"institutions":[{"id":"https://openalex.org/I177477856","display_name":"Polytechnic University of Turin","ror":"https://ror.org/00bgk9508","country_code":"IT","type":"education","lineage":["https://openalex.org/I177477856"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Daniela Renga","raw_affiliation_strings":["Politecnico di Torino,Italy"],"affiliations":[{"raw_affiliation_string":"Politecnico di Torino,Italy","institution_ids":["https://openalex.org/I177477856"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5004090870"],"corresponding_institution_ids":["https://openalex.org/I177477856"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.45806015,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10663","display_name":"Advanced Battery Technologies Research","score":0.795799970626831,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10663","display_name":"Advanced Battery Technologies Research","score":0.795799970626831,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12238","display_name":"Green IT and Sustainability","score":0.09769999980926514,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10768","display_name":"Electric Vehicles and Infrastructure","score":0.03889999911189079,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/battery","display_name":"Battery (electricity)","score":0.7736999988555908},{"id":"https://openalex.org/keywords/sizing","display_name":"Sizing","score":0.6650999784469604},{"id":"https://openalex.org/keywords/base-station","display_name":"Base station","score":0.6334999799728394},{"id":"https://openalex.org/keywords/photovoltaic-system","display_name":"Photovoltaic system","score":0.5809000134468079},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.5307000279426575},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.46209999918937683},{"id":"https://openalex.org/keywords/degradation","display_name":"Degradation (telecommunications)","score":0.4440000057220459},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4133000075817108},{"id":"https://openalex.org/keywords/energy-storage","display_name":"Energy storage","score":0.3986000120639801}],"concepts":[{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.7736999988555908},{"id":"https://openalex.org/C2777767291","wikidata":"https://www.wikidata.org/wiki/Q1080291","display_name":"Sizing","level":2,"score":0.6650999784469604},{"id":"https://openalex.org/C68649174","wikidata":"https://www.wikidata.org/wiki/Q1379116","display_name":"Base station","level":2,"score":0.6334999799728394},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.5809000134468079},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.5307000279426575},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.5069000124931335},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.46209999918937683},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.459199994802475},{"id":"https://openalex.org/C2779679103","wikidata":"https://www.wikidata.org/wiki/Q5251805","display_name":"Degradation (telecommunications)","level":2,"score":0.4440000057220459},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.41920000314712524},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4133000075817108},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.3986000120639801},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3776000142097473},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.3718000054359436},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.3215000033378601},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.31139999628067017},{"id":"https://openalex.org/C2780106510","wikidata":"https://www.wikidata.org/wiki/Q4822597","display_name":"Depth of discharge","level":4,"score":0.29989999532699585},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2978000044822693},{"id":"https://openalex.org/C42058472","wikidata":"https://www.wikidata.org/wiki/Q810214","display_name":"Base (topology)","level":2,"score":0.28870001435279846},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.28630000352859497},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.2786000072956085},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.2784999907016754},{"id":"https://openalex.org/C2984118289","wikidata":"https://www.wikidata.org/wiki/Q29954","display_name":"Power consumption","level":3,"score":0.2727999985218048},{"id":"https://openalex.org/C206034944","wikidata":"https://www.wikidata.org/wiki/Q1780509","display_name":"Telecommunications equipment","level":2,"score":0.2655999958515167},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.2653000056743622},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.2624000012874603},{"id":"https://openalex.org/C423512","wikidata":"https://www.wikidata.org/wiki/Q383973","display_name":"Electricity generation","level":3,"score":0.25870001316070557},{"id":"https://openalex.org/C104708988","wikidata":"https://www.wikidata.org/wiki/Q1664450","display_name":"Stand-alone power system","level":4,"score":0.25130000710487366}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/pimrc62392.2025.11275142","is_oa":false,"landing_page_url":"https://doi.org/10.1109/pimrc62392.2025.11275142","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE 36th International Symposium on Personal, Indoor and Mobile Radio Communications (PIMRC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W2070407158","https://openalex.org/W3002107335","https://openalex.org/W3033098655","https://openalex.org/W3110163562","https://openalex.org/W4307479757","https://openalex.org/W4312084299","https://openalex.org/W4312301485","https://openalex.org/W4323664191","https://openalex.org/W4391584169","https://openalex.org/W4404447830","https://openalex.org/W4408358178"],"related_works":[],"abstract_inverted_index":{"Telecom":[0],"base":[1,80],"stations":[2],"increasingly":[3],"rely":[4],"on":[5],"solar":[6],"power":[7,82],"and":[8,27,45,67,73,104],"battery":[9,18,40,68,93,115],"storage":[10],"to":[11,24,70,98,101],"achieve":[12],"sustainable,":[13],"cost-effective":[14,58],"energy":[15,59,121],"solutions,":[16],"but":[17],"degradation":[19,47],"poses":[20],"a":[21,49,124],"significant":[22],"challenge":[23],"system":[25,75],"reliability":[26],"longevity.":[28],"This":[29],"paper":[30],"introduces":[31],"an":[32,106],"innovative":[33],"optimization":[34],"framework":[35,62],"that":[36],"accounts":[37],"for":[38,54,127],"lithium-ion":[39],"aging,":[41],"modeling":[42],"both":[43],"calendar":[44],"cycle":[46,94],"with":[48],"novel":[50],"segment-based":[51],"approach.":[52],"Designed":[53],"seamless":[55],"integration":[56],"into":[57],"planning,":[60],"the":[61],"optimizes":[63],"photovoltaic":[64],"(PV)":[65],"panel":[66],"sizing":[69],"minimize":[71],"costs":[72],"extend":[74],"lifespan.":[76],"Validated":[77],"using":[78],"real-world":[79],"station":[81],"consumption":[83],"data,":[84],"our":[85],"approach":[86],"outperforms":[87],"traditional":[88],"rainflow-based":[89,110],"aging":[90],"models,":[91],"reducing":[92],"wear":[95],"by":[96,105],"up":[97],"65.5%":[99],"compared":[100],"aging-unaware":[102],"methods":[103],"additional":[107],"10%":[108],"over":[109],"methods.":[111],"By":[112],"enabling":[113],"real-time":[114],"health":[116],"tracking,":[117],"it":[118],"supports":[119],"dynamic":[120],"management,":[122],"offering":[123],"practical":[125],"solution":[126],"sustainable":[128],"telecom":[129],"networks.":[130]},"counts_by_year":[],"updated_date":"2026-03-07T16:01:11.037858","created_date":"2025-12-12T00:00:00"}
