{"id":"https://openalex.org/W2289508897","doi":"https://doi.org/10.1109/pccc.2015.7410292","title":"Power-free Structural Health Monitoring via compressive sensing","display_name":"Power-free Structural Health Monitoring via compressive sensing","publication_year":2015,"publication_date":"2015-12-01","ids":{"openalex":"https://openalex.org/W2289508897","doi":"https://doi.org/10.1109/pccc.2015.7410292","mag":"2289508897"},"language":"en","primary_location":{"id":"doi:10.1109/pccc.2015.7410292","is_oa":false,"landing_page_url":"https://doi.org/10.1109/pccc.2015.7410292","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE 34th International Performance Computing and Communications Conference (IPCCC)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5050228714","display_name":"Jumin Zhao","orcid":"https://orcid.org/0000-0002-9049-4053"},"institutions":[{"id":"https://openalex.org/I9086337","display_name":"Taiyuan University of Technology","ror":"https://ror.org/03kv08d37","country_code":"CN","type":"education","lineage":["https://openalex.org/I9086337"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Ju-min Zhao","raw_affiliation_strings":["Information Engineering College of Taiyuan University of Technology, Taiyuan, Shanxi, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Information Engineering College of Taiyuan University of Technology, Taiyuan, Shanxi, China","institution_ids":["https://openalex.org/I9086337"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5059568370","display_name":"Feng Ding","orcid":"https://orcid.org/0000-0001-7642-4182"},"institutions":[{"id":"https://openalex.org/I174104030","display_name":"Taiyuan Normal University","ror":"https://ror.org/051k00p03","country_code":"CN","type":"education","lineage":["https://openalex.org/I174104030"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Ding Feng","raw_affiliation_strings":["Computer Science and Technology Department, Taiyuan Normal University, Taiyuan, Shanxi, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Computer Science and Technology Department, Taiyuan Normal University, Taiyuan, Shanxi, China","institution_ids":["https://openalex.org/I174104030"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101474050","display_name":"Dengao Li","orcid":null},"institutions":[{"id":"https://openalex.org/I9086337","display_name":"Taiyuan University of Technology","ror":"https://ror.org/03kv08d37","country_code":"CN","type":"education","lineage":["https://openalex.org/I9086337"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Deng-ao Li","raw_affiliation_strings":["Information Engineering College of Taiyuan University of Technology, Taiyuan, Shanxi, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Information Engineering College of Taiyuan University of Technology, Taiyuan, Shanxi, China","institution_ids":["https://openalex.org/I9086337"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5002069259","display_name":"Baofeng Zhao","orcid":"https://orcid.org/0000-0002-4920-2661"},"institutions":[{"id":"https://openalex.org/I9086337","display_name":"Taiyuan University of Technology","ror":"https://ror.org/03kv08d37","country_code":"CN","type":"education","lineage":["https://openalex.org/I9086337"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Bao-feng Zhao","raw_affiliation_strings":["Information Engineering College of Taiyuan University of Technology, Taiyuan, Shanxi, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Information Engineering College of Taiyuan University of Technology, Taiyuan, Shanxi, China","institution_ids":["https://openalex.org/I9086337"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":"16","issue":null,"first_page":"1","last_page":"8"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10326","display_name":"Indoor and Outdoor Localization Technologies","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10326","display_name":"Indoor and Outdoor Localization Technologies","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10080","display_name":"Energy Efficient Wireless Sensor Networks","score":0.9973000288009644,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11192","display_name":"Underwater Vehicles and Communication Systems","score":0.996999979019165,"subfield":{"id":"https://openalex.org/subfields/2212","display_name":"Ocean Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/structural-health-monitoring","display_name":"Structural health monitoring","score":0.817475438117981},{"id":"https://openalex.org/keywords/compressed-sensing","display_name":"Compressed sensing","score":0.769392728805542},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6537888050079346},{"id":"https://openalex.org/keywords/wireless-sensor-network","display_name":"Wireless sensor network","score":0.5359286665916443},{"id":"https://openalex.org/keywords/trace","display_name":"TRACE (psycholinguistics)","score":0.49257761240005493},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4872266352176666},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.46787282824516296},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.4236685335636139},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.42035746574401855},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.3266119658946991},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.2588004171848297},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.2341936230659485},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.1670348048210144},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.16013145446777344},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.1121145486831665}],"concepts":[{"id":"https://openalex.org/C2776247918","wikidata":"https://www.wikidata.org/wiki/Q1423713","display_name":"Structural health monitoring","level":2,"score":0.817475438117981},{"id":"https://openalex.org/C124851039","wikidata":"https://www.wikidata.org/wiki/Q2665459","display_name":"Compressed sensing","level":2,"score":0.769392728805542},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6537888050079346},{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.5359286665916443},{"id":"https://openalex.org/C75291252","wikidata":"https://www.wikidata.org/wiki/Q1315756","display_name":"TRACE (psycholinguistics)","level":2,"score":0.49257761240005493},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4872266352176666},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.46787282824516296},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4236685335636139},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.42035746574401855},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.3266119658946991},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.2588004171848297},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2341936230659485},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.1670348048210144},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.16013145446777344},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.1121145486831665},{"id":"https://openalex.org/C138885662","wikidata":"https://www.wikidata.org/wiki/Q5891","display_name":"Philosophy","level":0,"score":0.0},{"id":"https://openalex.org/C41895202","wikidata":"https://www.wikidata.org/wiki/Q8162","display_name":"Linguistics","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/pccc.2015.7410292","is_oa":false,"landing_page_url":"https://doi.org/10.1109/pccc.2015.7410292","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE 34th International Performance Computing and Communications Conference (IPCCC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.5699999928474426,"id":"https://metadata.un.org/sdg/12","display_name":"Responsible consumption and production"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320325529","display_name":"University of Venda","ror":"https://ror.org/0338xea48"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":27,"referenced_works":["https://openalex.org/W1495958990","https://openalex.org/W1985716339","https://openalex.org/W2009008240","https://openalex.org/W2019368871","https://openalex.org/W2023647137","https://openalex.org/W2024316309","https://openalex.org/W2027272808","https://openalex.org/W2028486351","https://openalex.org/W2074308254","https://openalex.org/W2089372109","https://openalex.org/W2100617218","https://openalex.org/W2101201152","https://openalex.org/W2105749254","https://openalex.org/W2109449402","https://openalex.org/W2132401136","https://openalex.org/W2143946380","https://openalex.org/W2147008944","https://openalex.org/W2147458995","https://openalex.org/W2161455381","https://openalex.org/W2164452299","https://openalex.org/W2170028174","https://openalex.org/W2296616510","https://openalex.org/W3004350858","https://openalex.org/W4231502663","https://openalex.org/W4250955649","https://openalex.org/W6657835177","https://openalex.org/W6681631672"],"related_works":["https://openalex.org/W2158224665","https://openalex.org/W2379589510","https://openalex.org/W2810730439","https://openalex.org/W4300044672","https://openalex.org/W1881631164","https://openalex.org/W2358292267","https://openalex.org/W2378166785","https://openalex.org/W1964277756","https://openalex.org/W2465351041","https://openalex.org/W1497025342"],"abstract_inverted_index":{"Structural":[0],"Health":[1],"Monitoring":[2],"(SHM)":[3],"plays":[4],"an":[5],"important":[6],"rule":[7],"to":[8,46,69,81],"improve":[9],"life":[10],"safety":[11],"and":[12,112],"achieve":[13],"economic":[14],"benefits.":[15],"The":[16,107],"use":[17],"of":[18,55,78,92,114],"conventional":[19],"wireless":[20],"sensor":[21],"networks":[22],"for":[23,30],"SHM":[24,49,72],"incurs":[25],"a":[26,61,102],"huge":[27],"maintenance":[28],"cost":[29],"frequent":[31],"battery":[32],"changes.":[33],"In":[34],"this":[35],"paper,":[36],"we":[37,59],"adopt":[38],"passive":[39],"RFID":[40],"tags,":[41],"which":[42],"are":[43],"power-free":[44,62],"devices,":[45],"build":[47],"fine-grained":[48],"systems.":[50],"To":[51],"get":[52],"timely":[53],"report":[54],"the":[56,76,90,95,110],"monitoring":[57,63],"data,":[58],"propose":[60],"scheme":[64],"with":[65,85],"compressive":[66,79],"sensing":[67,80],"(PFM-CS)":[68],"collect":[70],"aggregated":[71],"events.":[73],"It":[74],"takes":[75],"advantage":[77],"reconstruct":[82],"original":[83],"events":[84],"high":[86],"accuracy.":[87],"We":[88],"evaluate":[89],"performance":[91],"PFM-CS":[93],"using":[94],"real":[96],"world":[97],"data":[98],"trace":[99],"collected":[100],"from":[101],"nineteen-storey":[103],"building":[104],"in":[105],"Singapore.":[106],"results":[108],"validate":[109],"effectiveness":[111],"efficiency":[113],"PFM-CS.":[115]},"counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2017,"cited_by_count":1}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
