{"id":"https://openalex.org/W2102519464","doi":"https://doi.org/10.1109/pccc.2009.5403821","title":"Thermal aware workload scheduling with backfilling for green data centers","display_name":"Thermal aware workload scheduling with backfilling for green data centers","publication_year":2009,"publication_date":"2009-12-01","ids":{"openalex":"https://openalex.org/W2102519464","doi":"https://doi.org/10.1109/pccc.2009.5403821","mag":"2102519464"},"language":"en","primary_location":{"id":"doi:10.1109/pccc.2009.5403821","is_oa":false,"landing_page_url":"https://doi.org/10.1109/pccc.2009.5403821","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2009 IEEE 28th International Performance Computing and Communications Conference","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5009116003","display_name":"Lizhe Wang","orcid":"https://orcid.org/0000-0003-2766-0845"},"institutions":[{"id":"https://openalex.org/I155173764","display_name":"Rochester Institute of Technology","ror":"https://ror.org/00v4yb702","country_code":"US","type":"education","lineage":["https://openalex.org/I155173764"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Lizhe Wang","raw_affiliation_strings":["Service Oriented Cyberinfrastructure Laboratory, Rochester Institute of Technology, Rochester, NY, USA","Service Oriented Cyberinfrastructure Lab, Rochester Institute of Technology, NY 14623, USA"],"affiliations":[{"raw_affiliation_string":"Service Oriented Cyberinfrastructure Laboratory, Rochester Institute of Technology, Rochester, NY, USA","institution_ids":["https://openalex.org/I155173764"]},{"raw_affiliation_string":"Service Oriented Cyberinfrastructure Lab, Rochester Institute of Technology, NY 14623, USA","institution_ids":["https://openalex.org/I155173764"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5006991539","display_name":"Gregor von Laszewski","orcid":"https://orcid.org/0000-0001-9558-179X"},"institutions":[{"id":"https://openalex.org/I4210119109","display_name":"Indiana University Bloomington","ror":"https://ror.org/02k40bc56","country_code":"US","type":"education","lineage":["https://openalex.org/I4210119109","https://openalex.org/I592451"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Gregor von Laszewski","raw_affiliation_strings":["Pervasive Technology Institute, Indiana University Bloomington, Bloomington, IN, USA","Pervasive Technology Institute, Indiana University at Bloomington, 47408, USA"],"affiliations":[{"raw_affiliation_string":"Pervasive Technology Institute, Indiana University Bloomington, Bloomington, IN, USA","institution_ids":["https://openalex.org/I4210119109"]},{"raw_affiliation_string":"Pervasive Technology Institute, Indiana University at Bloomington, 47408, USA","institution_ids":["https://openalex.org/I4210119109"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5110213948","display_name":"Jai Dayal","orcid":"https://orcid.org/0000-0002-1715-364X"},"institutions":[{"id":"https://openalex.org/I155173764","display_name":"Rochester Institute of Technology","ror":"https://ror.org/00v4yb702","country_code":"US","type":"education","lineage":["https://openalex.org/I155173764"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Jai Dayal","raw_affiliation_strings":["Service Oriented Cyberinfrastructure Laboratory, Rochester Institute of Technology, Rochester, NY, USA","Service Oriented Cyberinfrastructure Lab, Rochester Institute of Technology, NY 14623, USA"],"affiliations":[{"raw_affiliation_string":"Service Oriented Cyberinfrastructure Laboratory, Rochester Institute of Technology, Rochester, NY, USA","institution_ids":["https://openalex.org/I155173764"]},{"raw_affiliation_string":"Service Oriented Cyberinfrastructure Lab, Rochester Institute of Technology, NY 14623, USA","institution_ids":["https://openalex.org/I155173764"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5086695342","display_name":"Thomas R. Furlani","orcid":"https://orcid.org/0000-0002-4683-0814"},"institutions":[{"id":"https://openalex.org/I57206974","display_name":"New York University","ror":"https://ror.org/0190ak572","country_code":"US","type":"education","lineage":["https://openalex.org/I57206974"]},{"id":"https://openalex.org/I63190737","display_name":"University at Buffalo, State University of New York","ror":"https://ror.org/01y64my43","country_code":"US","type":"education","lineage":["https://openalex.org/I63190737"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Thomas R. Furlani","raw_affiliation_strings":["Center of Computational Research, State University of New York, University at Buffalo, Buffalo, NY, USA","Center for Computational Research, State University of New York at Buffalo, 14203, USA"],"affiliations":[{"raw_affiliation_string":"Center of Computational Research, State University of New York, University at Buffalo, Buffalo, NY, USA","institution_ids":["https://openalex.org/I63190737","https://openalex.org/I57206974"]},{"raw_affiliation_string":"Center for Computational Research, State University of New York at Buffalo, 14203, USA","institution_ids":["https://openalex.org/I63190737"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5009116003"],"corresponding_institution_ids":["https://openalex.org/I155173764"],"apc_list":null,"apc_paid":null,"fwci":11.1045,"has_fulltext":false,"cited_by_count":42,"citation_normalized_percentile":{"value":0.98173072,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"289","last_page":"296"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10101","display_name":"Cloud Computing and Resource Management","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10101","display_name":"Cloud Computing and Resource Management","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10054","display_name":"Parallel Computing and Optimization Techniques","score":0.9973000288009644,"subfield":{"id":"https://openalex.org/subfields/1708","display_name":"Hardware and Architecture"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11181","display_name":"Advanced Data Storage Technologies","score":0.9940999746322632,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/data-center","display_name":"Data center","score":0.9000791311264038},{"id":"https://openalex.org/keywords/workload","display_name":"Workload","score":0.7628189325332642},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6885203719139099},{"id":"https://openalex.org/keywords/scheduling","display_name":"Scheduling (production processes)","score":0.632394552230835},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.5575295686721802},{"id":"https://openalex.org/keywords/power-consumption","display_name":"Power consumption","score":0.5129311084747314},{"id":"https://openalex.org/keywords/thermal","display_name":"Thermal","score":0.41624850034713745},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.3838609755039215},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.27959179878234863},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.18293669819831848},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.1391981840133667},{"id":"https://openalex.org/keywords/operations-management","display_name":"Operations management","score":0.10871315002441406},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.10214310884475708},{"id":"https://openalex.org/keywords/meteorology","display_name":"Meteorology","score":0.08883452415466309}],"concepts":[{"id":"https://openalex.org/C153740404","wikidata":"https://www.wikidata.org/wiki/Q671224","display_name":"Data center","level":2,"score":0.9000791311264038},{"id":"https://openalex.org/C2778476105","wikidata":"https://www.wikidata.org/wiki/Q628539","display_name":"Workload","level":2,"score":0.7628189325332642},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6885203719139099},{"id":"https://openalex.org/C206729178","wikidata":"https://www.wikidata.org/wiki/Q2271896","display_name":"Scheduling (production processes)","level":2,"score":0.632394552230835},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.5575295686721802},{"id":"https://openalex.org/C2984118289","wikidata":"https://www.wikidata.org/wiki/Q29954","display_name":"Power consumption","level":3,"score":0.5129311084747314},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.41624850034713745},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.3838609755039215},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.27959179878234863},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.18293669819831848},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.1391981840133667},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.10871315002441406},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.10214310884475708},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.08883452415466309},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/pccc.2009.5403821","is_oa":false,"landing_page_url":"https://doi.org/10.1109/pccc.2009.5403821","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2009 IEEE 28th International Performance Computing and Communications Conference","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.550000011920929,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":23,"referenced_works":["https://openalex.org/W190397983","https://openalex.org/W1504382467","https://openalex.org/W1676458374","https://openalex.org/W1933251158","https://openalex.org/W1994261587","https://openalex.org/W2051929630","https://openalex.org/W2085039517","https://openalex.org/W2093336106","https://openalex.org/W2100404320","https://openalex.org/W2106119405","https://openalex.org/W2116009028","https://openalex.org/W2117108296","https://openalex.org/W2137500257","https://openalex.org/W2150654762","https://openalex.org/W2165424134","https://openalex.org/W2170002197","https://openalex.org/W2172090472","https://openalex.org/W2536745924","https://openalex.org/W4242900150","https://openalex.org/W4298093392","https://openalex.org/W6637307316","https://openalex.org/W6677357164","https://openalex.org/W6684811251"],"related_works":["https://openalex.org/W2000785801","https://openalex.org/W986318368","https://openalex.org/W2384410913","https://openalex.org/W2352878646","https://openalex.org/W2004734601","https://openalex.org/W2130149817","https://openalex.org/W3188789063","https://openalex.org/W4214747436","https://openalex.org/W1893812361","https://openalex.org/W2998055095"],"abstract_inverted_index":{"Data":[0],"centers":[1,140],"now":[2],"play":[3],"an":[4,52,75],"important":[5],"role":[6],"in":[7,39,54,61,111,138,145],"modern":[8],"IT":[9],"infrastructures.":[10],"Related":[11],"research":[12],"has":[13,24],"shown":[14],"that":[15,35,131],"the":[16,62,123,126],"energy":[17],"consumption":[18,108],"for":[19,69],"data":[20,41,70,80,113,139],"center":[21,42,81],"cooling":[22],"systems":[23],"recently":[25],"increased":[26],"significantly.":[27],"There":[28],"is":[29,101,118],"also":[30],"strong":[31],"evidence":[32],"to":[33,45,105,121],"show":[34,130],"high":[36],"temperatures":[37,110,137],"with":[38,83,89,99],"a":[40,93,112],"will":[43],"lead":[44],"higher":[46],"hardware":[47],"failure":[48],"rates":[49],"and":[50,87,109],"thus":[51],"increase":[53],"maintenance":[55],"costs.":[56],"This":[57,72],"paper":[58,73],"devotes":[59],"itself":[60],"field":[63],"of":[64,125],"thermal":[65,90,94],"aware":[66,95],"resource":[67],"management":[68],"centers.":[71],"proposes":[74],"analytical":[76],"model,":[77],"which":[78,103],"describes":[79],"resources":[82],"heat":[84],"transfer":[85],"properties":[86],"workloads":[88],"features.":[91],"Then":[92],"task":[96],"scheduling":[97],"algorithm":[98,133],"backfilling":[100],"presented":[102],"aims":[104],"reduce":[106,136],"power":[107],"center.":[114],"A":[115],"simulation":[116],"study":[117],"carried":[119],"out":[120],"evaluate":[122],"performance":[124],"algorithm.":[127],"Simulation":[128],"results":[129],"our":[132],"can":[134],"significantly":[135],"by":[141],"introducing":[142],"endurable":[143],"decline":[144],"performance.":[146]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":1},{"year":2019,"cited_by_count":2},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":2},{"year":2016,"cited_by_count":4},{"year":2015,"cited_by_count":4},{"year":2014,"cited_by_count":5},{"year":2013,"cited_by_count":5},{"year":2012,"cited_by_count":6}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
