{"id":"https://openalex.org/W7147448091","doi":"https://doi.org/10.1109/osmses69376.2026.11457207","title":"From Co-Simulation to Composition: A Data-Driven Transformer with OLTC for Scalable Open-Source Power System Modeling","display_name":"From Co-Simulation to Composition: A Data-Driven Transformer with OLTC for Scalable Open-Source Power System Modeling","publication_year":2026,"publication_date":"2026-03-23","ids":{"openalex":"https://openalex.org/W7147448091","doi":"https://doi.org/10.1109/osmses69376.2026.11457207"},"language":null,"primary_location":{"id":"doi:10.1109/osmses69376.2026.11457207","is_oa":false,"landing_page_url":"https://doi.org/10.1109/osmses69376.2026.11457207","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2026 Open Source Modelling and Simulation of Energy Systems (OSMSES)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5118268036","display_name":"Sebastian Eichhorn","orcid":null},"institutions":[{"id":"https://openalex.org/I62916508","display_name":"Technical University of Munich","ror":"https://ror.org/02kkvpp62","country_code":"DE","type":"education","lineage":["https://openalex.org/I62916508"]}],"countries":["DE"],"is_corresponding":true,"raw_author_name":"Sebastian Eichhorn","raw_affiliation_strings":["Technical University of Munich,Munich,Germany"],"affiliations":[{"raw_affiliation_string":"Technical University of Munich,Munich,Germany","institution_ids":["https://openalex.org/I62916508"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5077434264","display_name":"Darlene J. Dullius","orcid":"https://orcid.org/0009-0002-2613-718X"},"institutions":[{"id":"https://openalex.org/I62916508","display_name":"Technical University of Munich","ror":"https://ror.org/02kkvpp62","country_code":"DE","type":"education","lineage":["https://openalex.org/I62916508"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Darlene Dullius","raw_affiliation_strings":["Technical University of Munich,Munich,Germany"],"affiliations":[{"raw_affiliation_string":"Technical University of Munich,Munich,Germany","institution_ids":["https://openalex.org/I62916508"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5073199811","display_name":"Anurag Mohapatra","orcid":"https://orcid.org/0009-0003-2745-6518"},"institutions":[{"id":"https://openalex.org/I62916508","display_name":"Technical University of Munich","ror":"https://ror.org/02kkvpp62","country_code":"DE","type":"education","lineage":["https://openalex.org/I62916508"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Anurag Mohapatra","raw_affiliation_strings":["Technical University of Munich,Munich,Germany"],"affiliations":[{"raw_affiliation_string":"Technical University of Munich,Munich,Germany","institution_ids":["https://openalex.org/I62916508"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5044965116","display_name":"Reinaldo Tonkoski","orcid":"https://orcid.org/0000-0003-3057-1085"},"institutions":[{"id":"https://openalex.org/I62916508","display_name":"Technical University of Munich","ror":"https://ror.org/02kkvpp62","country_code":"DE","type":"education","lineage":["https://openalex.org/I62916508"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Reinaldo Tonkoski","raw_affiliation_strings":["Technical University of Munich,Munich,Germany"],"affiliations":[{"raw_affiliation_string":"Technical University of Munich,Munich,Germany","institution_ids":["https://openalex.org/I62916508"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5118268036"],"corresponding_institution_ids":["https://openalex.org/I62916508"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.92736729,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.43639999628067017,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.43639999628067017,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.22499999403953552,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11052","display_name":"Energy Load and Power Forecasting","score":0.07530000060796738,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/scalability","display_name":"Scalability","score":0.6647999882698059},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5221999883651733},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.505299985408783},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.4397999942302704},{"id":"https://openalex.org/keywords/robustness","display_name":"Robustness (evolution)","score":0.4374000132083893},{"id":"https://openalex.org/keywords/control-system","display_name":"Control system","score":0.38609999418258667},{"id":"https://openalex.org/keywords/nonlinear-system","display_name":"Nonlinear system","score":0.34209999442100525},{"id":"https://openalex.org/keywords/system-identification","display_name":"System identification","score":0.3402000069618225},{"id":"https://openalex.org/keywords/identification","display_name":"Identification (biology)","score":0.32899999618530273},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.3206999897956848}],"concepts":[{"id":"https://openalex.org/C48044578","wikidata":"https://www.wikidata.org/wiki/Q727490","display_name":"Scalability","level":2,"score":0.6647999882698059},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5891000032424927},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5221999883651733},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.505299985408783},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.45159998536109924},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.4397999942302704},{"id":"https://openalex.org/C63479239","wikidata":"https://www.wikidata.org/wiki/Q7353546","display_name":"Robustness (evolution)","level":3,"score":0.4374000132083893},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.38609999418258667},{"id":"https://openalex.org/C158622935","wikidata":"https://www.wikidata.org/wiki/Q660848","display_name":"Nonlinear system","level":2,"score":0.34209999442100525},{"id":"https://openalex.org/C119247159","wikidata":"https://www.wikidata.org/wiki/Q1366192","display_name":"System identification","level":3,"score":0.3402000069618225},{"id":"https://openalex.org/C116834253","wikidata":"https://www.wikidata.org/wiki/Q2039217","display_name":"Identification (biology)","level":2,"score":0.32899999618530273},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.3206999897956848},{"id":"https://openalex.org/C122940293","wikidata":"https://www.wikidata.org/wiki/Q1755966","display_name":"Tap changer","level":4,"score":0.3118000030517578},{"id":"https://openalex.org/C107645828","wikidata":"https://www.wikidata.org/wiki/Q12070446","display_name":"System model","level":2,"score":0.3107999861240387},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.30730000138282776},{"id":"https://openalex.org/C20136886","wikidata":"https://www.wikidata.org/wiki/Q749647","display_name":"Interoperability","level":2,"score":0.3050999939441681},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.30239999294281006},{"id":"https://openalex.org/C163175372","wikidata":"https://www.wikidata.org/wiki/Q3339222","display_name":"Linear model","level":2,"score":0.29440000653266907},{"id":"https://openalex.org/C2778907243","wikidata":"https://www.wikidata.org/wiki/Q168160","display_name":"IEC 61850","level":3,"score":0.2912999987602234},{"id":"https://openalex.org/C172205157","wikidata":"https://www.wikidata.org/wiki/Q1782962","display_name":"Model predictive control","level":3,"score":0.2883000075817108},{"id":"https://openalex.org/C2778763806","wikidata":"https://www.wikidata.org/wiki/Q4826572","display_name":"Automatic Generation Control","level":4,"score":0.28780001401901245},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.2865000069141388},{"id":"https://openalex.org/C6802819","wikidata":"https://www.wikidata.org/wiki/Q1072174","display_name":"Linear system","level":2,"score":0.28439998626708984},{"id":"https://openalex.org/C48921125","wikidata":"https://www.wikidata.org/wiki/Q10861030","display_name":"Linear regression","level":2,"score":0.2777999937534332},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.2777999937534332},{"id":"https://openalex.org/C149441793","wikidata":"https://www.wikidata.org/wiki/Q200726","display_name":"Probability distribution","level":2,"score":0.2728999853134155},{"id":"https://openalex.org/C67186912","wikidata":"https://www.wikidata.org/wiki/Q367664","display_name":"Data modeling","level":2,"score":0.2720000147819519},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.26159998774528503},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.2612000107765198},{"id":"https://openalex.org/C116219307","wikidata":"https://www.wikidata.org/wiki/Q7236625","display_name":"Power system simulation","level":4,"score":0.2597000002861023},{"id":"https://openalex.org/C65620979","wikidata":"https://www.wikidata.org/wiki/Q7661176","display_name":"Symbolic data analysis","level":2,"score":0.2590999901294708},{"id":"https://openalex.org/C114289077","wikidata":"https://www.wikidata.org/wiki/Q3284399","display_name":"Statistical model","level":2,"score":0.2565000057220459},{"id":"https://openalex.org/C31531917","wikidata":"https://www.wikidata.org/wiki/Q915157","display_name":"Robust control","level":3,"score":0.2517000138759613},{"id":"https://openalex.org/C83546350","wikidata":"https://www.wikidata.org/wiki/Q1139051","display_name":"Regression","level":2,"score":0.25130000710487366}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/osmses69376.2026.11457207","is_oa":false,"landing_page_url":"https://doi.org/10.1109/osmses69376.2026.11457207","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2026 Open Source Modelling and Simulation of Energy Systems (OSMSES)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":8,"referenced_works":["https://openalex.org/W3080358587","https://openalex.org/W3100142611","https://openalex.org/W3138791207","https://openalex.org/W4321608455","https://openalex.org/W4391621012","https://openalex.org/W4411345870","https://openalex.org/W4415564855","https://openalex.org/W7117582653"],"related_works":[],"abstract_inverted_index":{"The":[0,110,124],"control":[1,119,150,160,169],"challenge":[2,33],"of":[3,134,147,158,170],"the":[4,12,117,148],"power":[5],"system":[6],"increases":[7],"with":[8,26],"its":[9],"complexity":[10],"and":[11,17,22,29,53,94,104,144,168],"rise":[13],"in":[14,132,138,161],"distribution-level":[15],"load":[16],"generation.":[18],"Incomplete":[19],"network":[20,56],"documentation":[21],"closed-source":[23],"simulation":[24],"tools":[25],"limited":[27],"interoperability":[28],"scalability":[30],"pose":[31],"a":[32,100,162,171],"for":[34,87],"Distribution":[35],"System":[36],"Operators":[37],"(DSOs).":[38],"High-fidelity,":[39],"topology-free":[40],"open-source":[41],"models":[42,86],"could":[43],"enable":[44,154],"leveraging":[45],"existing":[46],"data":[47],"as":[48],"scalable":[49],"surrogate":[50,111],"networks.":[51],"Low-(LV)":[52],"medium-voltage":[54],"(MV)":[55],"surrogates":[57],"can":[58],"be":[59],"built":[60],"separately":[61],"at":[62],"different":[63],"detail":[64],"levels,":[65],"but":[66],"they":[67],"mutually":[68],"influence":[69],"each":[70],"other.":[71],"Their":[72],"interaction":[73],"is":[74,113],"mediated":[75],"by":[76],"on-load":[77],"tap":[78],"changer":[79],"(OLTC)":[80],"transformers.":[81],"This":[82,136],"paper":[83],"proposes":[84],"data-driven":[85],"this":[88],"OLTC":[89,118],"transformer":[90],"based":[91],"on":[92],"symbolic":[93,126],"linear":[95,130],"regression,":[96],"enabling":[97,165],"coupling":[98],"between":[99],"balanced":[101],"MV":[102],"model":[103,112,128],"an":[105],"unbalanced":[106],"LV":[107],"power-flow":[108],"model.":[109],"used":[114],"to":[115],"identify":[116],"parameters":[120],"from":[121],"time-series":[122],"data.":[123],"nonlinear":[125],"regression":[127,131],"outperforms":[129],"terms":[133],"precision.":[135],"results":[137,153],"fewer":[139],"incorrectly":[140],"predicted":[141],"switching":[142],"events":[143],"robust":[145,156],"identification":[146],"underlying":[149],"parameters.":[151],"These":[152],"high-speed,":[155],"modeling":[157],"tap-changer":[159],"distribution":[163,173],"grid,":[164],"real-time":[166],"analysis":[167],"large":[172],"grid":[174],"across":[175],"multiple":[176],"voltage":[177],"levels.":[178]},"counts_by_year":[],"updated_date":"2026-04-02T13:53:19.096889","created_date":"2026-04-02T00:00:00"}