{"id":"https://openalex.org/W1970250626","doi":"https://doi.org/10.1109/onlinegreencom.2013.6731034","title":"Energy-aware data center management in cross-domain content delivery networks","display_name":"Energy-aware data center management in cross-domain content delivery networks","publication_year":2013,"publication_date":"2013-10-01","ids":{"openalex":"https://openalex.org/W1970250626","doi":"https://doi.org/10.1109/onlinegreencom.2013.6731034","mag":"1970250626"},"language":"en","primary_location":{"id":"doi:10.1109/onlinegreencom.2013.6731034","is_oa":false,"landing_page_url":"https://doi.org/10.1109/onlinegreencom.2013.6731034","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 IEEE Online Conference on Green Communications (OnlineGreenComm)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5023658974","display_name":"Chang Ge","orcid":"https://orcid.org/0000-0002-1828-7105"},"institutions":[{"id":"https://openalex.org/I28290843","display_name":"University of Surrey","ror":"https://ror.org/00ks66431","country_code":"GB","type":"education","lineage":["https://openalex.org/I28290843"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Chang Ge","raw_affiliation_strings":["Centre for Communication Systems Research, University of Surrey, Guildford, UK","Centre for Communication Systems Research, University of Surrey, Guildford, UK#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Centre for Communication Systems Research, University of Surrey, Guildford, UK","institution_ids":["https://openalex.org/I28290843"]},{"raw_affiliation_string":"Centre for Communication Systems Research, University of Surrey, Guildford, UK#TAB#","institution_ids":["https://openalex.org/I28290843"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100387221","display_name":"Ning Wang","orcid":"https://orcid.org/0000-0003-3053-0515"},"institutions":[{"id":"https://openalex.org/I28290843","display_name":"University of Surrey","ror":"https://ror.org/00ks66431","country_code":"GB","type":"education","lineage":["https://openalex.org/I28290843"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Ning Wang","raw_affiliation_strings":["Centre for Communication Systems Research, University of Surrey, Guildford, UK","Centre for Communication Systems Research, University of Surrey, Guildford, UK#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Centre for Communication Systems Research, University of Surrey, Guildford, UK","institution_ids":["https://openalex.org/I28290843"]},{"raw_affiliation_string":"Centre for Communication Systems Research, University of Surrey, Guildford, UK#TAB#","institution_ids":["https://openalex.org/I28290843"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5058697093","display_name":"Zhili Sun","orcid":"https://orcid.org/0000-0002-1909-4946"},"institutions":[{"id":"https://openalex.org/I28290843","display_name":"University of Surrey","ror":"https://ror.org/00ks66431","country_code":"GB","type":"education","lineage":["https://openalex.org/I28290843"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Zhili Sun","raw_affiliation_strings":["Centre for Communication Systems Research, University of Surrey, Guildford, UK","Centre for Communication Systems Research, University of Surrey, Guildford, UK#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Centre for Communication Systems Research, University of Surrey, Guildford, UK","institution_ids":["https://openalex.org/I28290843"]},{"raw_affiliation_string":"Centre for Communication Systems Research, University of Surrey, Guildford, UK#TAB#","institution_ids":["https://openalex.org/I28290843"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I28290843"],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"88","last_page":"95"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11478","display_name":"Caching and Content Delivery","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11478","display_name":"Caching and Content Delivery","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10101","display_name":"Cloud Computing and Resource Management","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11181","display_name":"Advanced Data Storage Technologies","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/server","display_name":"Server","score":0.820825457572937},{"id":"https://openalex.org/keywords/content-delivery-network","display_name":"Content delivery network","score":0.8008878231048584},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7864238023757935},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.7506145238876343},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.6998617649078369},{"id":"https://openalex.org/keywords/provisioning","display_name":"Provisioning","score":0.687773585319519},{"id":"https://openalex.org/keywords/data-center","display_name":"Data center","score":0.6776567697525024},{"id":"https://openalex.org/keywords/quality-of-service","display_name":"Quality of service","score":0.6322633028030396},{"id":"https://openalex.org/keywords/cache","display_name":"Cache","score":0.5284929871559143},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.5019228458404541},{"id":"https://openalex.org/keywords/sleep-mode","display_name":"Sleep mode","score":0.4534206688404083},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.10966572165489197}],"concepts":[{"id":"https://openalex.org/C93996380","wikidata":"https://www.wikidata.org/wiki/Q44127","display_name":"Server","level":2,"score":0.820825457572937},{"id":"https://openalex.org/C2778898579","wikidata":"https://www.wikidata.org/wiki/Q72588","display_name":"Content delivery network","level":3,"score":0.8008878231048584},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7864238023757935},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.7506145238876343},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.6998617649078369},{"id":"https://openalex.org/C172191483","wikidata":"https://www.wikidata.org/wiki/Q1071806","display_name":"Provisioning","level":2,"score":0.687773585319519},{"id":"https://openalex.org/C153740404","wikidata":"https://www.wikidata.org/wiki/Q671224","display_name":"Data center","level":2,"score":0.6776567697525024},{"id":"https://openalex.org/C5119721","wikidata":"https://www.wikidata.org/wiki/Q220501","display_name":"Quality of service","level":2,"score":0.6322633028030396},{"id":"https://openalex.org/C115537543","wikidata":"https://www.wikidata.org/wiki/Q165596","display_name":"Cache","level":2,"score":0.5284929871559143},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.5019228458404541},{"id":"https://openalex.org/C57149124","wikidata":"https://www.wikidata.org/wiki/Q587346","display_name":"Sleep mode","level":4,"score":0.4534206688404083},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.10966572165489197},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C2984118289","wikidata":"https://www.wikidata.org/wiki/Q29954","display_name":"Power consumption","level":3,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/onlinegreencom.2013.6731034","is_oa":false,"landing_page_url":"https://doi.org/10.1109/onlinegreencom.2013.6731034","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 IEEE Online Conference on Green Communications (OnlineGreenComm)","raw_type":"proceedings-article"},{"id":"pmh:oai:research-information.bris.ac.uk:openaire_cris_publications/67d83eb8-5178-49f2-ad35-a669e3da4b07","is_oa":false,"landing_page_url":"https://research-information.bris.ac.uk/en/publications/67d83eb8-5178-49f2-ad35-a669e3da4b07","pdf_url":null,"source":{"id":"https://openalex.org/S4306400895","display_name":"Bristol Research (University of Bristol)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I36234482","host_organization_name":"University of Bristol","host_organization_lineage":["https://openalex.org/I36234482"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Ge, C, Wang, N & Sun, Z 2013, Energy-aware data center management in cross-domain content delivery networks. in 2013 IEEE Online Conference on Green Communications, OnlineGreenComm 2013., 6731034, 2013 IEEE Online Conference on Green Communications, OnlineGreenComm 2013, pp. 88-95. https://doi.org/10.1109/OnlineGreenCom.2013.6731034","raw_type":"contributionToPeriodical"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.9100000262260437,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W1976986662","https://openalex.org/W1986697120","https://openalex.org/W1999971903","https://openalex.org/W2021622753","https://openalex.org/W2044979851","https://openalex.org/W2066297293","https://openalex.org/W2107198105","https://openalex.org/W2130335803","https://openalex.org/W2130384722","https://openalex.org/W2134807578","https://openalex.org/W2153446963","https://openalex.org/W6655980677"],"related_works":["https://openalex.org/W2017432143","https://openalex.org/W1973694374","https://openalex.org/W2020533706","https://openalex.org/W2247454500","https://openalex.org/W2765987083","https://openalex.org/W2948189595","https://openalex.org/W2161594841","https://openalex.org/W1625044673","https://openalex.org/W1547435337","https://openalex.org/W4380878435"],"abstract_inverted_index":{"A":[0],"content":[1,25,56,92,158],"delivery":[2,93],"network":[3,65,101,151],"(CDN)":[4],"typically":[5],"consists":[6],"of":[7,32,83],"geographically-distributed":[8],"data":[9,34,73,121,172,198],"centers,":[10],"each":[11],"containing":[12],"servers":[13,89,118,149],"that":[14,77],"cache":[15],"and":[16,54,63,90,100,150],"deliver":[17],"Web":[18],"contents":[19],"close":[20],"to":[21,97,125,132,169,183,196,204],"end-users":[22],"for":[23],"localized":[24],"access":[26],"purpose.":[27],"In":[28,67],"recent":[29],"years,":[30],"optimization":[31],"CDN":[33,51,120,139,171,189],"center":[35,74,173,199],"energy":[36,52,81,174,200],"consumption":[37,53,82,175,201],"has":[38],"attracted":[39],"increasing":[40],"research":[41],"efforts.":[42],"The":[43,103],"key":[44],"technical":[45],"challenge":[46],"is":[47,143,167,194],"the":[48,55,61,64,80,109,126,136,164,191],"tradeoff":[49,111],"between":[50],"service":[57],"capability":[58],"at":[59],"both":[60],"server":[62,99],"sides.":[66],"this":[68],"article,":[69],"we":[70],"introduce":[71],"a":[72,162],"management":[75],"scheme":[76,105,166,193],"effectively":[78],"reduces":[79],"cross-domain":[84],"CDNs":[85],"through":[86,145,155],"dynamically":[87],"provisioning":[88],"coordinating":[91],"operations":[94],"with":[95],"respect":[96],"dynamic":[98],"load.":[102],"proposed":[104,165,192],"focuses":[106],"on":[107,148,187],"optimizing":[108],"energy-performance":[110],"in":[112,119],"two":[113],"aspects.":[114],"On":[115,135],"one":[116],"hand,":[117,138],"centers":[122],"are":[123],"put":[124],"sleep":[127],"mode":[128],"during":[129],"off-peak":[130],"hours":[131],"save":[133],"energy.":[134],"other":[137],"Quality-of-Service":[140],"(QoS)":[141],"performance":[142],"assured":[144],"honoring":[146],"constraints":[147],"link":[152],"loads,":[153],"especially":[154],"restricting":[156],"inter-domain":[157],"traffic":[159],"volume.":[160],"As":[161],"result,":[163],"able":[168,195],"reduce":[170,197],"without":[176],"compromising":[177],"its":[178],"end-to-end":[179],"QoS":[180,209],"performance.":[181,210],"According":[182],"our":[184],"experiments":[185],"based":[186],"realistic":[188],"scenarios,":[190],"by":[202],"up":[203],"45.9%":[205],"while":[206],"achieving":[207],"desired":[208]},"counts_by_year":[{"year":2021,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":1}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
