{"id":"https://openalex.org/W4409917017","doi":"https://doi.org/10.1109/ocit65031.2024.00129","title":"Design of Mho Type Distance Relay Scheme for Protection of Transmission Line Using EnerVista Software for D60 Relays","display_name":"Design of Mho Type Distance Relay Scheme for Protection of Transmission Line Using EnerVista Software for D60 Relays","publication_year":2024,"publication_date":"2024-12-12","ids":{"openalex":"https://openalex.org/W4409917017","doi":"https://doi.org/10.1109/ocit65031.2024.00129"},"language":"en","primary_location":{"id":"doi:10.1109/ocit65031.2024.00129","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ocit65031.2024.00129","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 OITS International Conference on Information Technology (OCIT)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5087906692","display_name":"Anurag Govind Rao","orcid":null},"institutions":[{"id":"https://openalex.org/I116891498","display_name":"Siddhartha Medical College","ror":"https://ror.org/058pt1w78","country_code":"IN","type":"education","lineage":["https://openalex.org/I116891498"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"A. Guru Mohana Prasada Rao","raw_affiliation_strings":["V.R.Siddhartha Engineering College, Deemed to be University,Dept. of EEE,Vijayawada,India"],"affiliations":[{"raw_affiliation_string":"V.R.Siddhartha Engineering College, Deemed to be University,Dept. of EEE,Vijayawada,India","institution_ids":["https://openalex.org/I116891498"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5117372635","display_name":"Bindu Vadlamani","orcid":null},"institutions":[{"id":"https://openalex.org/I116891498","display_name":"Siddhartha Medical College","ror":"https://ror.org/058pt1w78","country_code":"IN","type":"education","lineage":["https://openalex.org/I116891498"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Bindu Vadlamani","raw_affiliation_strings":["V.R.Siddhartha Engineering College, Deemed to be University,Dept. of EEE,Vijayawada,India"],"affiliations":[{"raw_affiliation_string":"V.R.Siddhartha Engineering College, Deemed to be University,Dept. of EEE,Vijayawada,India","institution_ids":["https://openalex.org/I116891498"]}]},{"author_position":"last","author":{"id":null,"display_name":"Venkateswara Rao Bathina","orcid":null},"institutions":[{"id":"https://openalex.org/I116891498","display_name":"Siddhartha Medical College","ror":"https://ror.org/058pt1w78","country_code":"IN","type":"education","lineage":["https://openalex.org/I116891498"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Venkateswara Rao Bathina","raw_affiliation_strings":["V.R.Siddhartha Engineering College, Deemed to be University,Dept. of EEE,Vijayawada,India"],"affiliations":[{"raw_affiliation_string":"V.R.Siddhartha Engineering College, Deemed to be University,Dept. of EEE,Vijayawada,India","institution_ids":["https://openalex.org/I116891498"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5087906692"],"corresponding_institution_ids":["https://openalex.org/I116891498"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.36708926,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"714","last_page":"719"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.873199999332428,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.873199999332428,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13715","display_name":"Power Line Inspection Robots","score":0.8410999774932861,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14276","display_name":"Power Systems and Technologies","score":0.8264999985694885,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/relay","display_name":"Relay","score":0.6227291226387024},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5577071905136108},{"id":"https://openalex.org/keywords/protective-relay","display_name":"Protective relay","score":0.5483220815658569},{"id":"https://openalex.org/keywords/scheme","display_name":"Scheme (mathematics)","score":0.5086148977279663},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.48425886034965515},{"id":"https://openalex.org/keywords/siemens","display_name":"Siemens","score":0.45134398341178894},{"id":"https://openalex.org/keywords/software","display_name":"Software","score":0.44655129313468933},{"id":"https://openalex.org/keywords/line","display_name":"Line (geometry)","score":0.4398866891860962},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.2934143841266632},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.22863012552261353},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.21886283159255981},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.19073167443275452},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.097259521484375},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.06817924976348877}],"concepts":[{"id":"https://openalex.org/C2778156585","wikidata":"https://www.wikidata.org/wiki/Q174053","display_name":"Relay","level":3,"score":0.6227291226387024},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5577071905136108},{"id":"https://openalex.org/C2412688","wikidata":"https://www.wikidata.org/wiki/Q503732","display_name":"Protective relay","level":4,"score":0.5483220815658569},{"id":"https://openalex.org/C77618280","wikidata":"https://www.wikidata.org/wiki/Q1155772","display_name":"Scheme (mathematics)","level":2,"score":0.5086148977279663},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.48425886034965515},{"id":"https://openalex.org/C100053769","wikidata":"https://www.wikidata.org/wiki/Q169893","display_name":"Siemens","level":2,"score":0.45134398341178894},{"id":"https://openalex.org/C2777904410","wikidata":"https://www.wikidata.org/wiki/Q7397","display_name":"Software","level":2,"score":0.44655129313468933},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.4398866891860962},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2934143841266632},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.22863012552261353},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.21886283159255981},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.19073167443275452},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.097259521484375},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.06817924976348877},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ocit65031.2024.00129","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ocit65031.2024.00129","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 OITS International Conference on Information Technology (OCIT)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W1544930024","https://openalex.org/W2055564749","https://openalex.org/W2783161933","https://openalex.org/W3036907132"],"related_works":["https://openalex.org/W1973873454","https://openalex.org/W3142892065","https://openalex.org/W2384133917","https://openalex.org/W2056980334","https://openalex.org/W2874772501","https://openalex.org/W2673189356","https://openalex.org/W3116605813","https://openalex.org/W2186816342","https://openalex.org/W2327779871","https://openalex.org/W4385992698"],"abstract_inverted_index":{"Transmission":[0,95],"line":[1,96,196],"network":[2],"plays":[3],"an":[4],"important":[5],"role":[6],"in":[7,142],"transferring":[8],"power":[9,119],"from":[10],"Generating":[11],"stations":[12],"to":[13,18,29,32,67],"Distribution":[14],"centers":[15],"and":[16,48,86,101,103,114,116,151,156,159,168,200],"then":[17],"final":[19],"users.":[20],"The":[21],"transmission":[22,42,72,78,107,179,195],"lines":[23,43,108,180],"are":[24,44],"most":[25],"vulnerable":[26],"electrical":[27,35,57],"system":[28],"faults":[30,39],"compared":[31],"all":[33,54],"other":[34,149],"activities.":[36],"If":[37],"the":[38,55,75,90,112,123,127],"occurred":[40],"on":[41,71],"not":[45],"identified":[46],"immediately":[47],"rectified":[49],"without":[50],"delay":[51],"may":[52],"damage":[53],"connected":[56],"equipment":[58,64],"including":[59],"Switches,":[60],"Transformers,":[61],"Generators,":[62],"metering":[63,169],"etc,":[65],"due":[66],"high":[68],"fault":[69],"currents":[70],"lines.":[73],"For":[74],"protection":[76,97,177,193],"of":[77,92,106,118,126,178,191,194],"lines,":[79],"IEDs":[80],"can":[81,109,145,173],"be":[82,174],"used":[83,175],"very":[84],"effective":[85],"efficient":[87,100],"way.":[88],"With":[89],"advent":[91],"IED":[93,130,172],"relays":[94],"has":[98,135],"become":[99],"accurate":[102],"reliable.":[104],"Protection":[105],"also":[110,146,160],"improve":[111],"reliability":[113],"dependability":[115],"security":[117],"supply":[120],"by":[121,181],"isolating":[122],"faulty":[124],"section":[125],"network.":[128],"An":[129,171],"is":[131],"a":[132],"device":[133],"that":[134],"one":[136],"or":[137],"more":[138],"microprocessors":[139],"integrated":[140],"with":[141,148,153,197,202],"it.":[143],"It":[144],"communicate":[147],"devices":[150],"systems":[152],"standard":[154],"rules":[155],"protocols":[157],"established":[158],"performs":[161],"many":[162],"functions":[163],"like":[164],"protection,":[165],"automation,":[166],"control":[167],"etc.":[170,186],"for":[176],"comparing":[182],"currents,":[183],"voltages,":[184],"angles":[185],"This":[187],"paper":[188],"involves":[189],"simulation":[190],"Distance":[192],"various":[198],"features":[199],"models":[201],"IEDs.":[203]},"counts_by_year":[],"updated_date":"2026-04-16T08:26:57.006410","created_date":"2025-10-10T00:00:00"}
