{"id":"https://openalex.org/W2744624896","doi":"https://doi.org/10.1109/newcas.2017.8010190","title":"Simulation, analysis and identification of a Renewable energy system","display_name":"Simulation, analysis and identification of a Renewable energy system","publication_year":2017,"publication_date":"2017-06-01","ids":{"openalex":"https://openalex.org/W2744624896","doi":"https://doi.org/10.1109/newcas.2017.8010190","mag":"2744624896"},"language":"en","primary_location":{"id":"doi:10.1109/newcas.2017.8010190","is_oa":false,"landing_page_url":"https://doi.org/10.1109/newcas.2017.8010190","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 15th IEEE International New Circuits and Systems Conference (NEWCAS)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5008256181","display_name":"Abderrahmane Jarrou","orcid":null},"institutions":[{"id":"https://openalex.org/I4210110792","display_name":"Centre de Recherche en Automatique de Nancy","ror":"https://ror.org/022r5hc56","country_code":"FR","type":"facility","lineage":["https://openalex.org/I1294671590","https://openalex.org/I1294671590","https://openalex.org/I4210099203","https://openalex.org/I4210100260","https://openalex.org/I4210110792","https://openalex.org/I4210159245","https://openalex.org/I90183372"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Abderrahmane Jarrou","raw_affiliation_strings":["LPRI, Multidisciplinary Laboratory of Research and Innovation, Morocco","Research Center for Automatic Control of Nancy (CRAN), Lorraine University, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"LPRI, Multidisciplinary Laboratory of Research and Innovation, Morocco","institution_ids":[]},{"raw_affiliation_string":"Research Center for Automatic Control of Nancy (CRAN), Lorraine University, France","institution_ids":["https://openalex.org/I4210110792"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5107837721","display_name":"Dominique Sauter","orcid":null},"institutions":[{"id":"https://openalex.org/I4210110792","display_name":"Centre de Recherche en Automatique de Nancy","ror":"https://ror.org/022r5hc56","country_code":"FR","type":"facility","lineage":["https://openalex.org/I1294671590","https://openalex.org/I1294671590","https://openalex.org/I4210099203","https://openalex.org/I4210100260","https://openalex.org/I4210110792","https://openalex.org/I4210159245","https://openalex.org/I90183372"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Dominique Sauter","raw_affiliation_strings":["Research Center for Automatic Control of Nancy (CRAN), Lorraine University, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Research Center for Automatic Control of Nancy (CRAN), Lorraine University, France","institution_ids":["https://openalex.org/I4210110792"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I4210110792"],"apc_list":null,"apc_paid":null,"fwci":0.8027,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.67688827,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"401","last_page":"404"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9983999729156494,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9983999729156494,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.9825999736785889,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9764000177383423,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/trnsys","display_name":"TRNSYS","score":0.9850964546203613},{"id":"https://openalex.org/keywords/hvac","display_name":"HVAC","score":0.8323079943656921},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.7723259925842285},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.5905734896659851},{"id":"https://openalex.org/keywords/identification","display_name":"Identification (biology)","score":0.5310901403427124},{"id":"https://openalex.org/keywords/heat-pump","display_name":"Heat pump","score":0.49463459849357605},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.47824230790138245},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4717966914176941},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.4626157879829407},{"id":"https://openalex.org/keywords/battery","display_name":"Battery (electricity)","score":0.4380577802658081},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.35845285654067993},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.33856815099716187},{"id":"https://openalex.org/keywords/environmental-science","display_name":"Environmental science","score":0.3355415463447571},{"id":"https://openalex.org/keywords/architectural-engineering","display_name":"Architectural engineering","score":0.3290541470050812},{"id":"https://openalex.org/keywords/thermal","display_name":"Thermal","score":0.32589399814605713},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.23750221729278564},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.1610303819179535},{"id":"https://openalex.org/keywords/meteorology","display_name":"Meteorology","score":0.10629364848136902}],"concepts":[{"id":"https://openalex.org/C2778457487","wikidata":"https://www.wikidata.org/wiki/Q2384813","display_name":"TRNSYS","level":3,"score":0.9850964546203613},{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.8323079943656921},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.7723259925842285},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.5905734896659851},{"id":"https://openalex.org/C116834253","wikidata":"https://www.wikidata.org/wiki/Q2039217","display_name":"Identification (biology)","level":2,"score":0.5310901403427124},{"id":"https://openalex.org/C2776461528","wikidata":"https://www.wikidata.org/wiki/Q131313","display_name":"Heat pump","level":3,"score":0.49463459849357605},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.47824230790138245},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4717966914176941},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.4626157879829407},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.4380577802658081},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.35845285654067993},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.33856815099716187},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.3355415463447571},{"id":"https://openalex.org/C170154142","wikidata":"https://www.wikidata.org/wiki/Q150737","display_name":"Architectural engineering","level":1,"score":0.3290541470050812},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.32589399814605713},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.23750221729278564},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.1610303819179535},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.10629364848136902},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.0},{"id":"https://openalex.org/C59822182","wikidata":"https://www.wikidata.org/wiki/Q441","display_name":"Botany","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/newcas.2017.8010190","is_oa":false,"landing_page_url":"https://doi.org/10.1109/newcas.2017.8010190","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 15th IEEE International New Circuits and Systems Conference (NEWCAS)","raw_type":"proceedings-article"},{"id":"pmh:oai:HAL:hal-01628043v1","is_oa":false,"landing_page_url":"https://hal.science/hal-01628043","pdf_url":null,"source":{"id":"https://openalex.org/S4306402512","display_name":"HAL (Le Centre pour la Communication Scientifique Directe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1294671590","host_organization_name":"Centre National de la Recherche Scientifique","host_organization_lineage":["https://openalex.org/I1294671590"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"15th IEEE International New Circuits and Systems Conference, NEWCAS 2017, Jun 2017, Strasbourg, France. &#x27E8;10.1109/NEWCAS.2017.8010190&#x27E9;","raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8899999856948853,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":17,"referenced_works":["https://openalex.org/W1980191100","https://openalex.org/W2032589491","https://openalex.org/W2036771008","https://openalex.org/W2036778492","https://openalex.org/W2044032194","https://openalex.org/W2051389656","https://openalex.org/W2053861150","https://openalex.org/W2055626613","https://openalex.org/W2071409415","https://openalex.org/W2092792488","https://openalex.org/W2093011266","https://openalex.org/W2103471700","https://openalex.org/W2123231657","https://openalex.org/W2166375424","https://openalex.org/W2307494056","https://openalex.org/W2340167130","https://openalex.org/W2402261827"],"related_works":["https://openalex.org/W3048878006","https://openalex.org/W2093018201","https://openalex.org/W1975773549","https://openalex.org/W3004642470","https://openalex.org/W2125750222","https://openalex.org/W218696521","https://openalex.org/W3046823714","https://openalex.org/W4379163887","https://openalex.org/W2348218441","https://openalex.org/W2765258218"],"abstract_inverted_index":{"An":[0],"investigation":[1],"and":[2,55,73],"analysis":[3],"based":[4,69],"on":[5,10,70],"TRNSYS":[6],"simulation":[7],"are":[8,80],"reported":[9],"the":[11,23,38,52,56,59,62,84],"performance":[12],"of":[13,19,58],"a":[14,29,44,65],"renewable":[15],"energy":[16],"system":[17,32,49],"compound":[18],"two":[20],"parts.":[21],"In":[22],"first":[24],"part":[25,40],"(production)":[26],"we":[27,42],"consider":[28,43],"PV/wind":[30],"hybrid":[31],"with":[33],"battery":[34],"storage.":[35],"And":[36],"in":[37,64],"second":[39],"(consumption)":[41],"heat":[45],"pump":[46],"as":[47],"HVAC":[48],"to":[50],"insure":[51],"thermal":[53],"comfort":[54],"quality":[57],"air":[60],"for":[61,82],"occupants":[63],"meeting":[66],"room.":[67],"Then":[68],"Physical":[71],"knowledge":[72],"data":[74],"generated":[75],"by":[76],"TRNSYS,":[77],"explicit":[78],"models":[79],"obtained":[81],"all":[83],"equipments.":[85]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1}],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}
