{"id":"https://openalex.org/W2742583921","doi":"https://doi.org/10.1109/newcas.2017.8010183","title":"Prototype of a multispectral and multiwavelength pulse oximeter based on a BQJ sensor","display_name":"Prototype of a multispectral and multiwavelength pulse oximeter based on a BQJ sensor","publication_year":2017,"publication_date":"2017-06-01","ids":{"openalex":"https://openalex.org/W2742583921","doi":"https://doi.org/10.1109/newcas.2017.8010183","mag":"2742583921"},"language":"en","primary_location":{"id":"doi:10.1109/newcas.2017.8010183","is_oa":false,"landing_page_url":"https://doi.org/10.1109/newcas.2017.8010183","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 15th IEEE International New Circuits and Systems Conference (NEWCAS)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5002507793","display_name":"Alejandro Von Chong","orcid":"https://orcid.org/0000-0003-0221-833X"},"institutions":[{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"government","lineage":["https://openalex.org/I1294671590"]},{"id":"https://openalex.org/I4210148552","display_name":"Equipes Traitement de l'Information et Syst\u00e8mes","ror":"https://ror.org/0592ata02","country_code":"FR","type":"facility","lineage":["https://openalex.org/I1294671590","https://openalex.org/I1294671590","https://openalex.org/I4210142324","https://openalex.org/I4210148552","https://openalex.org/I4210159245","https://openalex.org/I86175216"]},{"id":"https://openalex.org/I86175216","display_name":"\u00c9cole Nationale Sup\u00e9rieure de l'\u00c9lectronique et de ses Applications","ror":"https://ror.org/03qeacd72","country_code":"FR","type":"education","lineage":["https://openalex.org/I86175216"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"A. Von Chong","raw_affiliation_strings":["ETIS / ENSEA, CNRS Cergy, Pontoise, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ETIS / ENSEA, CNRS Cergy, Pontoise, France","institution_ids":["https://openalex.org/I1294671590","https://openalex.org/I4210148552","https://openalex.org/I86175216"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5041657881","display_name":"Mehdi Terosiet","orcid":null},"institutions":[{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"government","lineage":["https://openalex.org/I1294671590"]},{"id":"https://openalex.org/I4210148552","display_name":"Equipes Traitement de l'Information et Syst\u00e8mes","ror":"https://ror.org/0592ata02","country_code":"FR","type":"facility","lineage":["https://openalex.org/I1294671590","https://openalex.org/I1294671590","https://openalex.org/I4210142324","https://openalex.org/I4210148552","https://openalex.org/I4210159245","https://openalex.org/I86175216"]},{"id":"https://openalex.org/I86175216","display_name":"\u00c9cole Nationale Sup\u00e9rieure de l'\u00c9lectronique et de ses Applications","ror":"https://ror.org/03qeacd72","country_code":"FR","type":"education","lineage":["https://openalex.org/I86175216"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"M. Terosiet","raw_affiliation_strings":["ETIS / ENSEA, CNRS Cergy, Pontoise, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ETIS / ENSEA, CNRS Cergy, Pontoise, France","institution_ids":["https://openalex.org/I1294671590","https://openalex.org/I4210148552","https://openalex.org/I86175216"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5107405298","display_name":"Aymeric Histace","orcid":null},"institutions":[{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"government","lineage":["https://openalex.org/I1294671590"]},{"id":"https://openalex.org/I4210148552","display_name":"Equipes Traitement de l'Information et Syst\u00e8mes","ror":"https://ror.org/0592ata02","country_code":"FR","type":"facility","lineage":["https://openalex.org/I1294671590","https://openalex.org/I1294671590","https://openalex.org/I4210142324","https://openalex.org/I4210148552","https://openalex.org/I4210159245","https://openalex.org/I86175216"]},{"id":"https://openalex.org/I86175216","display_name":"\u00c9cole Nationale Sup\u00e9rieure de l'\u00c9lectronique et de ses Applications","ror":"https://ror.org/03qeacd72","country_code":"FR","type":"education","lineage":["https://openalex.org/I86175216"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"A. Histace","raw_affiliation_strings":["ETIS / ENSEA, CNRS Cergy, Pontoise, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ETIS / ENSEA, CNRS Cergy, Pontoise, France","institution_ids":["https://openalex.org/I1294671590","https://openalex.org/I4210148552","https://openalex.org/I86175216"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5010347556","display_name":"Olivier Romain","orcid":"https://orcid.org/0000-0002-2172-1865"},"institutions":[{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"government","lineage":["https://openalex.org/I1294671590"]},{"id":"https://openalex.org/I4210148552","display_name":"Equipes Traitement de l'Information et Syst\u00e8mes","ror":"https://ror.org/0592ata02","country_code":"FR","type":"facility","lineage":["https://openalex.org/I1294671590","https://openalex.org/I1294671590","https://openalex.org/I4210142324","https://openalex.org/I4210148552","https://openalex.org/I4210159245","https://openalex.org/I86175216"]},{"id":"https://openalex.org/I86175216","display_name":"\u00c9cole Nationale Sup\u00e9rieure de l'\u00c9lectronique et de ses Applications","ror":"https://ror.org/03qeacd72","country_code":"FR","type":"education","lineage":["https://openalex.org/I86175216"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"O. Romain","raw_affiliation_strings":["ETIS / ENSEA, CNRS Cergy, Pontoise, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ETIS / ENSEA, CNRS Cergy, Pontoise, France","institution_ids":["https://openalex.org/I1294671590","https://openalex.org/I4210148552","https://openalex.org/I86175216"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.5045,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.58104617,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"373","last_page":"376"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10745","display_name":"Heart Rate Variability and Autonomic Control","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/pulse-oximetry","display_name":"Pulse oximetry","score":0.8008750677108765},{"id":"https://openalex.org/keywords/multispectral-image","display_name":"Multispectral image","score":0.687480628490448},{"id":"https://openalex.org/keywords/photodiode","display_name":"Photodiode","score":0.6720534563064575},{"id":"https://openalex.org/keywords/photodetector","display_name":"Photodetector","score":0.6276729106903076},{"id":"https://openalex.org/keywords/light-emitting-diode","display_name":"Light-emitting diode","score":0.6065883636474609},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.5624478459358215},{"id":"https://openalex.org/keywords/saturation","display_name":"Saturation (graph theory)","score":0.5260964632034302},{"id":"https://openalex.org/keywords/oxygen-saturation","display_name":"Oxygen saturation","score":0.4629092812538147},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.4574607312679291},{"id":"https://openalex.org/keywords/pulse","display_name":"Pulse (music)","score":0.4476729929447174},{"id":"https://openalex.org/keywords/optoelectronics","display_name":"Optoelectronics","score":0.42481833696365356},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.3822968304157257},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.37429139018058777},{"id":"https://openalex.org/keywords/detector","display_name":"Detector","score":0.2236480414867401},{"id":"https://openalex.org/keywords/oxygen","display_name":"Oxygen","score":0.20734712481498718},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.20330342650413513},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.1784687638282776},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.14891207218170166},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.11312973499298096}],"concepts":[{"id":"https://openalex.org/C2780124106","wikidata":"https://www.wikidata.org/wiki/Q1140495","display_name":"Pulse oximetry","level":2,"score":0.8008750677108765},{"id":"https://openalex.org/C173163844","wikidata":"https://www.wikidata.org/wiki/Q1761440","display_name":"Multispectral image","level":2,"score":0.687480628490448},{"id":"https://openalex.org/C751236","wikidata":"https://www.wikidata.org/wiki/Q175943","display_name":"Photodiode","level":2,"score":0.6720534563064575},{"id":"https://openalex.org/C23125352","wikidata":"https://www.wikidata.org/wiki/Q210765","display_name":"Photodetector","level":2,"score":0.6276729106903076},{"id":"https://openalex.org/C176666156","wikidata":"https://www.wikidata.org/wiki/Q25504","display_name":"Light-emitting diode","level":2,"score":0.6065883636474609},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5624478459358215},{"id":"https://openalex.org/C9930424","wikidata":"https://www.wikidata.org/wiki/Q7426587","display_name":"Saturation (graph theory)","level":2,"score":0.5260964632034302},{"id":"https://openalex.org/C76538665","wikidata":"https://www.wikidata.org/wiki/Q6294669","display_name":"Oxygen saturation","level":3,"score":0.4629092812538147},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.4574607312679291},{"id":"https://openalex.org/C2780167933","wikidata":"https://www.wikidata.org/wiki/Q1550652","display_name":"Pulse (music)","level":3,"score":0.4476729929447174},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.42481833696365356},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.3822968304157257},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.37429139018058777},{"id":"https://openalex.org/C94915269","wikidata":"https://www.wikidata.org/wiki/Q1834857","display_name":"Detector","level":2,"score":0.2236480414867401},{"id":"https://openalex.org/C540031477","wikidata":"https://www.wikidata.org/wiki/Q629","display_name":"Oxygen","level":2,"score":0.20734712481498718},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.20330342650413513},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.1784687638282776},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.14891207218170166},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.11312973499298096},{"id":"https://openalex.org/C42219234","wikidata":"https://www.wikidata.org/wiki/Q131130","display_name":"Anesthesia","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C114614502","wikidata":"https://www.wikidata.org/wiki/Q76592","display_name":"Combinatorics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/newcas.2017.8010183","is_oa":false,"landing_page_url":"https://doi.org/10.1109/newcas.2017.8010183","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 15th IEEE International New Circuits and Systems Conference (NEWCAS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":6,"referenced_works":["https://openalex.org/W1761886043","https://openalex.org/W2048238471","https://openalex.org/W2123754678","https://openalex.org/W2143721770","https://openalex.org/W2151950656","https://openalex.org/W2583712744"],"related_works":["https://openalex.org/W2021651157","https://openalex.org/W2121237629","https://openalex.org/W4385388608","https://openalex.org/W2072772419","https://openalex.org/W1976033608","https://openalex.org/W2010333896","https://openalex.org/W3073158291","https://openalex.org/W3172110902","https://openalex.org/W2090724925","https://openalex.org/W2051588342"],"abstract_inverted_index":{"Pulse":[0],"oximetry":[1],"is":[2],"one":[3],"of":[4,28,46,49,87,93,116,138,140],"the":[5,26,36,41,44,69,114,141],"most":[6],"commonly":[7],"employed":[8,59],"monitoring":[9],"modalities":[10],"in":[11,40,65,102],"critical":[12],"care":[13],"setting.":[14],"Conventional":[15],"pulse":[16],"oximeters,":[17],"use":[18],"two":[19],"leds":[20],"and":[21,30],"a":[22,60,78,97,128,135],"photodiode":[23],"to":[24,67,90],"estimate":[25,68],"percentage":[27],"oxyhemoglobin":[29],"deoxyhemoglobin,":[31],"assuming":[32],"that":[33,110],"those":[34],"are":[35],"only":[37],"light":[38],"absorbers":[39],"blood.":[42],"Nevertheless,":[43],"presence":[45],"other":[47],"types":[48,92],"dyshemoglobin":[50],"may":[51],"invalidate":[52],"their":[53],"calibration.":[54],"In":[55],"this":[56,107],"study,":[57],"we":[58,111],"Buried":[61],"Quad":[62],"Junction":[63],"photodetector":[64],"order":[66],"oxygen":[70,120,142],"saturation":[71,121,143],"using":[72],"simultaneously":[73,95],"lit":[74],"leds.":[75],"More":[76],"precisely,":[77],"proof-of-principle":[79],"was":[80],"shown":[81],"for":[82,119],"developing":[83],"an":[84],"oximeter":[85],"capable":[86],"estimating":[88],"up":[89],"four":[91],"hemoglobin":[94],"with":[96,106,127,134],"single":[98],"led.":[99],"Results":[100],"from":[101],"vivo":[103],"measurements":[104],"obtained":[105],"setup":[108],"show":[109],"successfully":[112],"isolated":[113],"information":[115],"our":[117],"interest":[118],"estimation.":[122,144],"These":[123],"results":[124],"were":[125],"compared":[126],"commercial":[129],"device":[130],"yielding":[131],"acceptable":[132],"estimations":[133],"mean":[136],"error":[137],"1.3%":[139]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2020,"cited_by_count":1}],"updated_date":"2026-07-30T17:31:21.811387","created_date":"2025-10-10T00:00:00"}
