{"id":"https://openalex.org/W2903871499","doi":"https://doi.org/10.1109/nems.2018.8556913","title":"A High-Performance Square pMUT for Range-finder","display_name":"A High-Performance Square pMUT for Range-finder","publication_year":2018,"publication_date":"2018-04-01","ids":{"openalex":"https://openalex.org/W2903871499","doi":"https://doi.org/10.1109/nems.2018.8556913","mag":"2903871499"},"language":"en","primary_location":{"id":"doi:10.1109/nems.2018.8556913","is_oa":false,"landing_page_url":"https://doi.org/10.1109/nems.2018.8556913","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE 13th Annual International Conference on Nano/Micro Engineered and Molecular Systems (NEMS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100379550","display_name":"Xinxin Liu","orcid":"https://orcid.org/0000-0002-6194-1117"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xinxin Liu","raw_affiliation_strings":["The State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"The State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5078369750","display_name":"Xuying Chen","orcid":"https://orcid.org/0000-0002-3577-4722"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xuying Chen","raw_affiliation_strings":["The State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"The State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5090307679","display_name":"Xianhao Le","orcid":"https://orcid.org/0000-0002-6084-3718"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xianhao Le","raw_affiliation_strings":["The State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"The State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5001480853","display_name":"Zhonggui Xu","orcid":null},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhonggui Xu","raw_affiliation_strings":["The State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"The State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100744960","display_name":"Changju Wu","orcid":"https://orcid.org/0000-0002-7423-3371"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Changju Wu","raw_affiliation_strings":["School of Aeronautics and Astronautics, Zhejiang University, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Aeronautics and Astronautics, Zhejiang University, China","institution_ids":["https://openalex.org/I76130692"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5060103378","display_name":"Jin Xie","orcid":"https://orcid.org/0000-0003-3942-3046"},"institutions":[{"id":"https://openalex.org/I76130692","display_name":"Zhejiang University","ror":"https://ror.org/00a2xv884","country_code":"CN","type":"education","lineage":["https://openalex.org/I76130692"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jin Xie","raw_affiliation_strings":["The State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"The State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, China","institution_ids":["https://openalex.org/I76130692"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.3345,"has_fulltext":false,"cited_by_count":18,"citation_normalized_percentile":{"value":0.59184903,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":null,"issue":null,"first_page":"106","last_page":"109"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11160","display_name":"Acoustic Wave Resonator Technologies","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11160","display_name":"Acoustic Wave Resonator Technologies","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10662","display_name":"Ultrasonics and Acoustic Wave Propagation","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10727","display_name":"Ultrasound Imaging and Elastography","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/pmut","display_name":"PMUT","score":0.8629734516143799},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.7085839509963989},{"id":"https://openalex.org/keywords/ultrasonic-sensor","display_name":"Ultrasonic sensor","score":0.6930135488510132},{"id":"https://openalex.org/keywords/piezoelectricity","display_name":"Piezoelectricity","score":0.5885607600212097},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.518835186958313},{"id":"https://openalex.org/keywords/square-wave","display_name":"Square wave","score":0.5142540335655212},{"id":"https://openalex.org/keywords/transducer","display_name":"Transducer","score":0.5079618096351624},{"id":"https://openalex.org/keywords/center-frequency","display_name":"Center frequency","score":0.5055737495422363},{"id":"https://openalex.org/keywords/square","display_name":"Square (algebra)","score":0.5041338205337524},{"id":"https://openalex.org/keywords/ultrasound","display_name":"Ultrasound","score":0.4180522561073303},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.26469552516937256},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.18704187870025635},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.1503297984600067},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.13164672255516052},{"id":"https://openalex.org/keywords/band-pass-filter","display_name":"Band-pass filter","score":0.10293382406234741},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.10003706812858582},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.06257098913192749}],"concepts":[{"id":"https://openalex.org/C57693265","wikidata":"https://www.wikidata.org/wiki/Q17105295","display_name":"PMUT","level":3,"score":0.8629734516143799},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.7085839509963989},{"id":"https://openalex.org/C81288441","wikidata":"https://www.wikidata.org/wiki/Q20736125","display_name":"Ultrasonic sensor","level":2,"score":0.6930135488510132},{"id":"https://openalex.org/C100082104","wikidata":"https://www.wikidata.org/wiki/Q183759","display_name":"Piezoelectricity","level":2,"score":0.5885607600212097},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.518835186958313},{"id":"https://openalex.org/C96352100","wikidata":"https://www.wikidata.org/wiki/Q1136640","display_name":"Square wave","level":3,"score":0.5142540335655212},{"id":"https://openalex.org/C56318395","wikidata":"https://www.wikidata.org/wiki/Q215928","display_name":"Transducer","level":2,"score":0.5079618096351624},{"id":"https://openalex.org/C7054721","wikidata":"https://www.wikidata.org/wiki/Q1940572","display_name":"Center frequency","level":3,"score":0.5055737495422363},{"id":"https://openalex.org/C135692309","wikidata":"https://www.wikidata.org/wiki/Q111124","display_name":"Square (algebra)","level":2,"score":0.5041338205337524},{"id":"https://openalex.org/C143753070","wikidata":"https://www.wikidata.org/wiki/Q162564","display_name":"Ultrasound","level":2,"score":0.4180522561073303},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.26469552516937256},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.18704187870025635},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.1503297984600067},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.13164672255516052},{"id":"https://openalex.org/C147788027","wikidata":"https://www.wikidata.org/wiki/Q2718101","display_name":"Band-pass filter","level":2,"score":0.10293382406234741},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.10003706812858582},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.06257098913192749},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/nems.2018.8556913","is_oa":false,"landing_page_url":"https://doi.org/10.1109/nems.2018.8556913","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE 13th Annual International Conference on Nano/Micro Engineered and Molecular Systems (NEMS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.7599999904632568,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W359173482","https://openalex.org/W942489103","https://openalex.org/W1987427413","https://openalex.org/W2020450456","https://openalex.org/W2072840621","https://openalex.org/W2108876112","https://openalex.org/W2124726994","https://openalex.org/W2159106460","https://openalex.org/W2163011994","https://openalex.org/W2177778300","https://openalex.org/W2289669073","https://openalex.org/W2291687963","https://openalex.org/W2743764621","https://openalex.org/W6697069942"],"related_works":["https://openalex.org/W2012283803","https://openalex.org/W4384820447","https://openalex.org/W2072454424","https://openalex.org/W2117438306","https://openalex.org/W2185942010","https://openalex.org/W4390293826","https://openalex.org/W1985705933","https://openalex.org/W2801309084","https://openalex.org/W2051847435","https://openalex.org/W2201063277"],"abstract_inverted_index":{"A":[0],"rangefinder":[1],"based":[2],"on":[3,53],"an":[4],"AIN":[5],"piezoelectric":[6],"micromachined":[7],"ultrasound":[8],"transducer":[9],"(pMUT)":[10],"is":[11],"presented":[12],"to":[13,17,32,44],"localize":[14],"targets":[15],"up":[16],"10":[18],"cm":[19],"using":[20],"pulse-echo":[21],"(PE)":[22],"mode.":[23],"An":[24],"experimental":[25],"set-up":[26],"has":[27],"been":[28],"described":[29],"and":[30,40,82],"implemented":[31],"characterize":[33],"two":[34],"kinds":[35],"of":[36,97],"pMUTs:":[37],"square":[38,58,77],"pMUT":[39,48,59,78],"circular":[41,47],"pMUT.":[42],"Compared":[43],"the":[45,54,57,73,76,95],"traditional":[46],"with":[49,60],"top":[50],"electrode":[51,63],"laying":[52],"center":[55],"part,":[56],"outer":[61],"frame-like":[62],"shows":[64],"better":[65],"performance":[66],"in":[67,88,100],"receiving":[68],"ultrasonic":[69],"waves.":[70],"Working":[71],"at":[72,94],"same":[74],"frequency,":[75],"saves":[79],"11.2%":[80],"area":[81],"can":[83],"achieve":[84],"higher":[85],"fill":[86],"factor":[87],"array.":[89],"Both":[90],"pMUTs":[91],"are":[92],"tested":[93],"frequency":[96],"400":[98],"kHz":[99],"air.":[101]},"counts_by_year":[{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":5},{"year":2023,"cited_by_count":4},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
