{"id":"https://openalex.org/W2565540869","doi":"https://doi.org/10.1109/nems.2016.7758214","title":"Design and simulation of a thermal flow sensor for gravity-driven microfluidic applications","display_name":"Design and simulation of a thermal flow sensor for gravity-driven microfluidic applications","publication_year":2016,"publication_date":"2016-04-01","ids":{"openalex":"https://openalex.org/W2565540869","doi":"https://doi.org/10.1109/nems.2016.7758214","mag":"2565540869"},"language":"en","primary_location":{"id":"doi:10.1109/nems.2016.7758214","is_oa":false,"landing_page_url":"https://doi.org/10.1109/nems.2016.7758214","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 IEEE 11th Annual International Conference on Nano/Micro Engineered and Molecular Systems (NEMS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5091155991","display_name":"Antti-Juhana M\u00e4ki","orcid":"https://orcid.org/0000-0001-7565-3530"},"institutions":[{"id":"https://openalex.org/I4210133110","display_name":"Tampere University","ror":null,"country_code":"FI","type":null,"lineage":["https://openalex.org/I4210133110"]}],"countries":["FI"],"is_corresponding":true,"raw_author_name":"Antti-Juhana Maki","raw_affiliation_strings":["Department of Automation Science and Engineering, BioMediTech Tampere University of Technology, Tampere, Finland"],"affiliations":[{"raw_affiliation_string":"Department of Automation Science and Engineering, BioMediTech Tampere University of Technology, Tampere, Finland","institution_ids":["https://openalex.org/I4210133110"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5013323886","display_name":"Anton Kontunen","orcid":"https://orcid.org/0000-0002-2220-1351"},"institutions":[{"id":"https://openalex.org/I4210133110","display_name":"Tampere University","ror":null,"country_code":"FI","type":null,"lineage":["https://openalex.org/I4210133110"]}],"countries":["FI"],"is_corresponding":false,"raw_author_name":"Anton Kontunen","raw_affiliation_strings":["Department of Automation Science and Engineering, BioMediTech Tampere University of Technology, Tampere, Finland"],"affiliations":[{"raw_affiliation_string":"Department of Automation Science and Engineering, BioMediTech Tampere University of Technology, Tampere, Finland","institution_ids":["https://openalex.org/I4210133110"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5052745471","display_name":"Tomi Ryyn\u00e4nen","orcid":"https://orcid.org/0000-0001-7424-1841"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Tomi Ryynanen","raw_affiliation_strings":["Tampereen yliopisto - Hervannan kampus, Tampere, Pirkanmaa, FI"],"affiliations":[{"raw_affiliation_string":"Tampereen yliopisto - Hervannan kampus, Tampere, Pirkanmaa, FI","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5051757454","display_name":"Jarmo Verho","orcid":"https://orcid.org/0000-0002-8272-4760"},"institutions":[{"id":"https://openalex.org/I4210133110","display_name":"Tampere University","ror":null,"country_code":"FI","type":null,"lineage":["https://openalex.org/I4210133110"]}],"countries":["FI"],"is_corresponding":false,"raw_author_name":"Jarmo Verho","raw_affiliation_strings":["Department of Automation Science and Engineering, BioMediTech Tampere University of Technology, Tampere, Finland"],"affiliations":[{"raw_affiliation_string":"Department of Automation Science and Engineering, BioMediTech Tampere University of Technology, Tampere, Finland","institution_ids":["https://openalex.org/I4210133110"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5031874991","display_name":"Joose Kreutzer","orcid":"https://orcid.org/0000-0001-5964-8707"},"institutions":[{"id":"https://openalex.org/I4210133110","display_name":"Tampere University","ror":null,"country_code":"FI","type":null,"lineage":["https://openalex.org/I4210133110"]}],"countries":["FI"],"is_corresponding":false,"raw_author_name":"Joose Kreutzer","raw_affiliation_strings":["Department of Automation Science and Engineering, BioMediTech Tampere University of Technology, Tampere, Finland"],"affiliations":[{"raw_affiliation_string":"Department of Automation Science and Engineering, BioMediTech Tampere University of Technology, Tampere, Finland","institution_ids":["https://openalex.org/I4210133110"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5010105730","display_name":"Jukka Lekkala","orcid":"https://orcid.org/0000-0001-9293-2240"},"institutions":[{"id":"https://openalex.org/I4210133110","display_name":"Tampere University","ror":null,"country_code":"FI","type":null,"lineage":["https://openalex.org/I4210133110"]}],"countries":["FI"],"is_corresponding":false,"raw_author_name":"Jukka Lekkala","raw_affiliation_strings":["Department of Automation Science and Engineering, BioMediTech Tampere University of Technology, Tampere, Finland"],"affiliations":[{"raw_affiliation_string":"Department of Automation Science and Engineering, BioMediTech Tampere University of Technology, Tampere, Finland","institution_ids":["https://openalex.org/I4210133110"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5082951245","display_name":"Pasi Kallio","orcid":"https://orcid.org/0000-0002-2890-6782"},"institutions":[{"id":"https://openalex.org/I4210133110","display_name":"Tampere University","ror":null,"country_code":"FI","type":null,"lineage":["https://openalex.org/I4210133110"]}],"countries":["FI"],"is_corresponding":false,"raw_author_name":"Pasi Kallio","raw_affiliation_strings":["Department of Automation Science and Engineering, BioMediTech Tampere University of Technology, Tampere, Finland"],"affiliations":[{"raw_affiliation_string":"Department of Automation Science and Engineering, BioMediTech Tampere University of Technology, Tampere, Finland","institution_ids":["https://openalex.org/I4210133110"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":7,"corresponding_author_ids":["https://openalex.org/A5091155991"],"corresponding_institution_ids":["https://openalex.org/I4210133110"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.14493116,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"125","last_page":"129"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10412","display_name":"Microfluidic and Capillary Electrophoresis Applications","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10412","display_name":"Microfluidic and Capillary Electrophoresis Applications","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11407","display_name":"Innovative Microfluidic and Catalytic Techniques Innovation","score":0.9987000226974487,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12452","display_name":"Electrowetting and Microfluidic Technologies","score":0.9979000091552734,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microfluidics","display_name":"Microfluidics","score":0.7339426875114441},{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.67598956823349},{"id":"https://openalex.org/keywords/flow","display_name":"Flow (mathematics)","score":0.6510199904441833},{"id":"https://openalex.org/keywords/flow-sensor","display_name":"Flow sensor","score":0.5229295492172241},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5156515836715698},{"id":"https://openalex.org/keywords/thermal","display_name":"Thermal","score":0.4837077260017395},{"id":"https://openalex.org/keywords/volumetric-flow-rate","display_name":"Volumetric flow rate","score":0.42940858006477356},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.41361361742019653},{"id":"https://openalex.org/keywords/mechanics","display_name":"Mechanics","score":0.3098050355911255},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.22882342338562012},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.18512588739395142},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.175578773021698},{"id":"https://openalex.org/keywords/nanotechnology","display_name":"Nanotechnology","score":0.16323703527450562},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.1607380211353302},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.07121223211288452},{"id":"https://openalex.org/keywords/meteorology","display_name":"Meteorology","score":0.0651090145111084}],"concepts":[{"id":"https://openalex.org/C8673954","wikidata":"https://www.wikidata.org/wiki/Q138845","display_name":"Microfluidics","level":2,"score":0.7339426875114441},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.67598956823349},{"id":"https://openalex.org/C38349280","wikidata":"https://www.wikidata.org/wiki/Q1434290","display_name":"Flow (mathematics)","level":2,"score":0.6510199904441833},{"id":"https://openalex.org/C2777153531","wikidata":"https://www.wikidata.org/wiki/Q15091623","display_name":"Flow sensor","level":2,"score":0.5229295492172241},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5156515836715698},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.4837077260017395},{"id":"https://openalex.org/C172120300","wikidata":"https://www.wikidata.org/wiki/Q1134348","display_name":"Volumetric flow rate","level":2,"score":0.42940858006477356},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.41361361742019653},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.3098050355911255},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.22882342338562012},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.18512588739395142},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.175578773021698},{"id":"https://openalex.org/C171250308","wikidata":"https://www.wikidata.org/wiki/Q11468","display_name":"Nanotechnology","level":1,"score":0.16323703527450562},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1607380211353302},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.07121223211288452},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.0651090145111084}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/nems.2016.7758214","is_oa":false,"landing_page_url":"https://doi.org/10.1109/nems.2016.7758214","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 IEEE 11th Annual International Conference on Nano/Micro Engineered and Molecular Systems (NEMS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.5899999737739563,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320321855","display_name":"Tekes","ror":"https://ror.org/02ag8cq23"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W1562661071","https://openalex.org/W1988608355","https://openalex.org/W2013638898","https://openalex.org/W2040661591","https://openalex.org/W2060942164","https://openalex.org/W2079158832","https://openalex.org/W2083977715","https://openalex.org/W2094884715","https://openalex.org/W2100850508","https://openalex.org/W2110730280","https://openalex.org/W2130212525","https://openalex.org/W2487708677"],"related_works":["https://openalex.org/W3103016203","https://openalex.org/W2106238498","https://openalex.org/W2463681241","https://openalex.org/W161520385","https://openalex.org/W4200355601","https://openalex.org/W2110778204","https://openalex.org/W97203997","https://openalex.org/W1572874849","https://openalex.org/W3011567024","https://openalex.org/W2981446296"],"abstract_inverted_index":{"Gravity-driven":[0],"flow":[1,26,46,59,99],"is":[2,22],"an":[3,89],"attractive":[4],"approach":[5],"to":[6,17,24,69],"develop":[7],"simpler":[8],"microfluidic":[9],"systems.":[10,30],"Because":[11],"clogged":[12],"microchannels":[13],"could":[14,85],"easily":[15],"lead":[16],"fatal":[18],"operational":[19],"failures,":[20],"it":[21],"crucial":[23],"monitor":[25],"rate":[27],"in":[28,61,93],"these":[29],"Therefore,":[31],"we":[32,56,66],"propose":[33],"here":[34],"for":[35],"the":[36,53,58,71,74,83,94],"first":[37],"time":[38],"a":[39,44,49,62],"numerical":[40],"model":[41,84],"that":[42],"combines":[43],"calorimetric":[45,98],"sensor":[47],"and":[48],"gravity-driven":[50,63,95],"system.":[51,64],"With":[52],"validated":[54],"model,":[55],"studied":[57],"behavior":[60],"Furthermore,":[65],"were":[67],"able":[68],"improve":[70],"sensitivity":[72],"of":[73],"measurement":[75],"based":[76],"on":[77],"simulation":[78],"results.":[79],"This":[80],"demonstrates,":[81],"how":[82],"be":[86],"used":[87],"as":[88],"effective":[90],"optimization":[91],"tool":[92],"system":[96],"including":[97],"measurement.":[100]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
