{"id":"https://openalex.org/W2121659398","doi":"https://doi.org/10.1109/nems.2014.6908883","title":"Capacitive micromachined ultrasonic transducer for ultra-low pressure detection","display_name":"Capacitive micromachined ultrasonic transducer for ultra-low pressure detection","publication_year":2014,"publication_date":"2014-04-01","ids":{"openalex":"https://openalex.org/W2121659398","doi":"https://doi.org/10.1109/nems.2014.6908883","mag":"2121659398"},"language":"en","primary_location":{"id":"doi:10.1109/nems.2014.6908883","is_oa":false,"landing_page_url":"https://doi.org/10.1109/nems.2014.6908883","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"The 9th IEEE International Conference on Nano/Micro Engineered and Molecular Systems (NEMS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5043647431","display_name":"Zhikang Li","orcid":"https://orcid.org/0000-0001-7017-0097"},"institutions":[{"id":"https://openalex.org/I87445476","display_name":"Xi'an Jiaotong University","ror":"https://ror.org/017zhmm22","country_code":"CN","type":"education","lineage":["https://openalex.org/I87445476"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Zhikang Li","raw_affiliation_strings":["State Key Laboratory for Manufacturing System Engineering, Xi'an Jiaotong University, Shannxi, China","State Key Laboratory for Manufacturing System Engineering, Xi'an Jiaotong University, Shannxi 710049, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Key Laboratory for Manufacturing System Engineering, Xi'an Jiaotong University, Shannxi, China","institution_ids":["https://openalex.org/I87445476"]},{"raw_affiliation_string":"State Key Laboratory for Manufacturing System Engineering, Xi'an Jiaotong University, Shannxi 710049, China","institution_ids":["https://openalex.org/I87445476"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5072118178","display_name":"Libo Zhao","orcid":"https://orcid.org/0000-0001-6101-8173"},"institutions":[{"id":"https://openalex.org/I87445476","display_name":"Xi'an Jiaotong University","ror":"https://ror.org/017zhmm22","country_code":"CN","type":"education","lineage":["https://openalex.org/I87445476"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Libo Zhao","raw_affiliation_strings":["State Key Laboratory for Manufacturing System Engineering, Xi'an Jiaotong University, Shannxi, China","State Key Laboratory for Manufacturing System Engineering, Xi'an Jiaotong University, Shannxi 710049, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Key Laboratory for Manufacturing System Engineering, Xi'an Jiaotong University, Shannxi, China","institution_ids":["https://openalex.org/I87445476"]},{"raw_affiliation_string":"State Key Laboratory for Manufacturing System Engineering, Xi'an Jiaotong University, Shannxi 710049, China","institution_ids":["https://openalex.org/I87445476"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5033373769","display_name":"Zhuangde Jiang","orcid":"https://orcid.org/0000-0001-5557-2653"},"institutions":[{"id":"https://openalex.org/I87445476","display_name":"Xi'an Jiaotong University","ror":"https://ror.org/017zhmm22","country_code":"CN","type":"education","lineage":["https://openalex.org/I87445476"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhuangde Jiang","raw_affiliation_strings":["State Key Laboratory for Manufacturing System Engineering, Xi'an Jiaotong University, Shannxi, China","State Key Laboratory for Manufacturing System Engineering, Xi'an Jiaotong University, Shannxi 710049, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Key Laboratory for Manufacturing System Engineering, Xi'an Jiaotong University, Shannxi, China","institution_ids":["https://openalex.org/I87445476"]},{"raw_affiliation_string":"State Key Laboratory for Manufacturing System Engineering, Xi'an Jiaotong University, Shannxi 710049, China","institution_ids":["https://openalex.org/I87445476"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5033340399","display_name":"Zhiying Ye","orcid":"https://orcid.org/0000-0003-2829-1068"},"institutions":[{"id":"https://openalex.org/I87445476","display_name":"Xi'an Jiaotong University","ror":"https://ror.org/017zhmm22","country_code":"CN","type":"education","lineage":["https://openalex.org/I87445476"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhiying Ye","raw_affiliation_strings":["State Key Laboratory for Manufacturing System Engineering, Xi'an Jiaotong University, Shannxi, China","State Key Laboratory for Manufacturing System Engineering, Xi'an Jiaotong University, Shannxi 710049, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Key Laboratory for Manufacturing System Engineering, Xi'an Jiaotong University, Shannxi, China","institution_ids":["https://openalex.org/I87445476"]},{"raw_affiliation_string":"State Key Laboratory for Manufacturing System Engineering, Xi'an Jiaotong University, Shannxi 710049, China","institution_ids":["https://openalex.org/I87445476"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5056618863","display_name":"Yulong Zhao","orcid":"https://orcid.org/0000-0003-2922-1037"},"institutions":[{"id":"https://openalex.org/I87445476","display_name":"Xi'an Jiaotong University","ror":"https://ror.org/017zhmm22","country_code":"CN","type":"education","lineage":["https://openalex.org/I87445476"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yulong Zhao","raw_affiliation_strings":["State Key Laboratory for Manufacturing System Engineering, Xi'an Jiaotong University, Shannxi, China","State Key Laboratory for Manufacturing System Engineering, Xi'an Jiaotong University, Shannxi 710049, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Key Laboratory for Manufacturing System Engineering, Xi'an Jiaotong University, Shannxi, China","institution_ids":["https://openalex.org/I87445476"]},{"raw_affiliation_string":"State Key Laboratory for Manufacturing System Engineering, Xi'an Jiaotong University, Shannxi 710049, China","institution_ids":["https://openalex.org/I87445476"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5043647431"],"corresponding_institution_ids":["https://openalex.org/I87445476"],"apc_list":null,"apc_paid":null,"fwci":0.2129,"has_fulltext":false,"cited_by_count":8,"citation_normalized_percentile":{"value":0.62021973,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":98},"biblio":{"volume":null,"issue":null,"first_page":"600","last_page":"603"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10369","display_name":"Advanced MEMS and NEMS Technologies","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10369","display_name":"Advanced MEMS and NEMS Technologies","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10338","display_name":"Advanced Sensor and Energy Harvesting Materials","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13928","display_name":"Advanced Sensor Technologies Research","score":0.9983000159263611,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/capacitive-micromachined-ultrasonic-transducers","display_name":"Capacitive micromachined ultrasonic transducers","score":0.9762918949127197},{"id":"https://openalex.org/keywords/capacitive-sensing","display_name":"Capacitive sensing","score":0.8001419305801392},{"id":"https://openalex.org/keywords/ultrasonic-sensor","display_name":"Ultrasonic sensor","score":0.7690573930740356},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.7035713195800781},{"id":"https://openalex.org/keywords/transducer","display_name":"Transducer","score":0.6805967092514038},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.6779570579528809},{"id":"https://openalex.org/keywords/pressure-sensor","display_name":"Pressure sensor","score":0.5978917479515076},{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.570968747138977},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.44266119599342346},{"id":"https://openalex.org/keywords/electrode","display_name":"Electrode","score":0.41419893503189087},{"id":"https://openalex.org/keywords/surface-micromachining","display_name":"Surface micromachining","score":0.4111877679824829},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.26026827096939087},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.2258802056312561},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.14567121863365173},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.0692172646522522},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.06861940026283264},{"id":"https://openalex.org/keywords/fabrication","display_name":"Fabrication","score":0.05936262011528015}],"concepts":[{"id":"https://openalex.org/C58772458","wikidata":"https://www.wikidata.org/wiki/Q5034480","display_name":"Capacitive micromachined ultrasonic transducers","level":3,"score":0.9762918949127197},{"id":"https://openalex.org/C206755178","wikidata":"https://www.wikidata.org/wiki/Q1131271","display_name":"Capacitive sensing","level":2,"score":0.8001419305801392},{"id":"https://openalex.org/C81288441","wikidata":"https://www.wikidata.org/wiki/Q20736125","display_name":"Ultrasonic sensor","level":2,"score":0.7690573930740356},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.7035713195800781},{"id":"https://openalex.org/C56318395","wikidata":"https://www.wikidata.org/wiki/Q215928","display_name":"Transducer","level":2,"score":0.6805967092514038},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.6779570579528809},{"id":"https://openalex.org/C41325743","wikidata":"https://www.wikidata.org/wiki/Q1261040","display_name":"Pressure sensor","level":2,"score":0.5978917479515076},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.570968747138977},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.44266119599342346},{"id":"https://openalex.org/C17525397","wikidata":"https://www.wikidata.org/wiki/Q176140","display_name":"Electrode","level":2,"score":0.41419893503189087},{"id":"https://openalex.org/C145667562","wikidata":"https://www.wikidata.org/wiki/Q7646003","display_name":"Surface micromachining","level":4,"score":0.4111877679824829},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.26026827096939087},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2258802056312561},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.14567121863365173},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0692172646522522},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.06861940026283264},{"id":"https://openalex.org/C136525101","wikidata":"https://www.wikidata.org/wiki/Q5428139","display_name":"Fabrication","level":3,"score":0.05936262011528015},{"id":"https://openalex.org/C204787440","wikidata":"https://www.wikidata.org/wiki/Q188504","display_name":"Alternative medicine","level":2,"score":0.0},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C142724271","wikidata":"https://www.wikidata.org/wiki/Q7208","display_name":"Pathology","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/nems.2014.6908883","is_oa":false,"landing_page_url":"https://doi.org/10.1109/nems.2014.6908883","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"The 9th IEEE International Conference on Nano/Micro Engineered and Molecular Systems (NEMS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W1973468826","https://openalex.org/W2005939786","https://openalex.org/W2013853238","https://openalex.org/W2015192345","https://openalex.org/W2056837344","https://openalex.org/W2101505555","https://openalex.org/W2115979089","https://openalex.org/W2150299650","https://openalex.org/W2151185782","https://openalex.org/W2161805833","https://openalex.org/W6682256325"],"related_works":["https://openalex.org/W2379368550","https://openalex.org/W2083007816","https://openalex.org/W3015749751","https://openalex.org/W2969556451","https://openalex.org/W4387713458","https://openalex.org/W2372430764","https://openalex.org/W4232987538","https://openalex.org/W4250278154","https://openalex.org/W4251271541","https://openalex.org/W4245074262"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"a":[3,11,89],"novel":[4],"approach":[5],"for":[6,63,88],"ultra-low":[7,64,127],"pressure":[8,65,77,111,128],"detection":[9],"using":[10],"capacitive":[12],"micromachined":[13],"ultrasonic":[14],"transducer":[15],"(CMUT)":[16],"as":[17,99],"the":[18,26,31,34,47,51,56,61,73,84,93,110,120,125],"sensing":[19,48],"element.":[20],"The":[21,37,53,67,76],"working":[22],"principle":[23],"depends":[24],"on":[25,109],"resonant":[27,68],"frequency":[28,69],"shift":[29],"of":[30,50,60,95,124],"CMUT":[32,62],"under":[33],"measured":[35,74],"pressure.":[36,75],"finite":[38],"element":[39],"method":[40],"(FEM)":[41],"simulations":[42],"were":[43,113],"employed":[44],"to":[45,119],"study":[46],"performance":[49],"CMUT.":[52,91],"results":[54],"demonstrated":[55],"feasibility":[57],"and":[58,107,122],"superiority":[59],"measurement.":[66],"varies":[70],"linearly":[71],"with":[72],"sensitivity":[78,112],"can":[79],"be":[80],"improved":[81],"by":[82],"increasing":[83],"bias":[85],"DC":[86],"voltage":[87],"certain":[90],"Additionally,":[92],"effects":[94],"structure":[96],"parameters":[97],"such":[98],"electrode":[100,102],"dimension,":[101],"separation":[103],"distance,":[104],"membrane":[105],"radius":[106],"thickness":[108],"also":[114],"studied,":[115],"which":[116],"will":[117],"contribute":[118],"design":[121],"operation":[123],"CMUT-based":[126],"sensor.":[129]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":2},{"year":2018,"cited_by_count":2},{"year":2017,"cited_by_count":1}],"updated_date":"2026-05-30T09:04:40.226872","created_date":"2025-10-10T00:00:00"}
