{"id":"https://openalex.org/W2048934166","doi":"https://doi.org/10.1109/nems.2013.6559733","title":"Simulation on heat transfer of the Light Switchable Microelectrode Array for retinal prosthesis","display_name":"Simulation on heat transfer of the Light Switchable Microelectrode Array for retinal prosthesis","publication_year":2013,"publication_date":"2013-04-01","ids":{"openalex":"https://openalex.org/W2048934166","doi":"https://doi.org/10.1109/nems.2013.6559733","mag":"2048934166"},"language":"en","primary_location":{"id":"doi:10.1109/nems.2013.6559733","is_oa":false,"landing_page_url":"https://doi.org/10.1109/nems.2013.6559733","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"The 8th Annual IEEE International Conference on Nano/Micro Engineered and Molecular Systems","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5006823895","display_name":"Tiancong Wang","orcid":"https://orcid.org/0000-0002-0936-5394"},"institutions":[{"id":"https://openalex.org/I20231570","display_name":"Peking University","ror":"https://ror.org/02v51f717","country_code":"CN","type":"education","lineage":["https://openalex.org/I20231570"]},{"id":"https://openalex.org/I4210119392","display_name":"Institute of Microelectronics","ror":"https://ror.org/02s6gs133","country_code":"CN","type":"facility","lineage":["https://openalex.org/I19820366","https://openalex.org/I4210119392"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Tiancong Wang","raw_affiliation_strings":["National Key Laboratory of Science and Technology on Micro, Nano Fabrication Institute of Microelectronics, Peking University, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Key Laboratory of Science and Technology on Micro, Nano Fabrication Institute of Microelectronics, Peking University, Beijing, China","institution_ids":["https://openalex.org/I20231570","https://openalex.org/I4210119392"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100381541","display_name":"Xinyi Zhang","orcid":"https://orcid.org/0000-0002-0581-9707"},"institutions":[{"id":"https://openalex.org/I20231570","display_name":"Peking University","ror":"https://ror.org/02v51f717","country_code":"CN","type":"education","lineage":["https://openalex.org/I20231570"]},{"id":"https://openalex.org/I4210119392","display_name":"Institute of Microelectronics","ror":"https://ror.org/02s6gs133","country_code":"CN","type":"facility","lineage":["https://openalex.org/I19820366","https://openalex.org/I4210119392"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xinyi Zhang","raw_affiliation_strings":["National Key Laboratory of Science and Technology on Micro, Nano Fabrication Institute of Microelectronics, Peking University, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Key Laboratory of Science and Technology on Micro, Nano Fabrication Institute of Microelectronics, Peking University, Beijing, China","institution_ids":["https://openalex.org/I20231570","https://openalex.org/I4210119392"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5042853342","display_name":"Zhihong Li","orcid":"https://orcid.org/0000-0003-0655-0567"},"institutions":[{"id":"https://openalex.org/I20231570","display_name":"Peking University","ror":"https://ror.org/02v51f717","country_code":"CN","type":"education","lineage":["https://openalex.org/I20231570"]},{"id":"https://openalex.org/I4210119392","display_name":"Institute of Microelectronics","ror":"https://ror.org/02s6gs133","country_code":"CN","type":"facility","lineage":["https://openalex.org/I19820366","https://openalex.org/I4210119392"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhihong Li","raw_affiliation_strings":["National Key Laboratory of Science and Technology on Micro, Nano Fabrication Institute of Microelectronics, Peking University, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Key Laboratory of Science and Technology on Micro, Nano Fabrication Institute of Microelectronics, Peking University, Beijing, China","institution_ids":["https://openalex.org/I20231570","https://openalex.org/I4210119392"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"286","last_page":"289"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11601","display_name":"Neuroscience and Neural Engineering","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2804","display_name":"Cellular and Molecular Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},"topics":[{"id":"https://openalex.org/T11601","display_name":"Neuroscience and Neural Engineering","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2804","display_name":"Cellular and Molecular Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},{"id":"https://openalex.org/T10502","display_name":"Advanced Memory and Neural Computing","score":0.9973000288009644,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12236","display_name":"Photoreceptor and optogenetics research","score":0.9948999881744385,"subfield":{"id":"https://openalex.org/subfields/2804","display_name":"Cellular and Molecular Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/multiphysics","display_name":"Multiphysics","score":0.9507006406784058},{"id":"https://openalex.org/keywords/retinal-prosthesis","display_name":"Retinal Prosthesis","score":0.7860626578330994},{"id":"https://openalex.org/keywords/joule-heating","display_name":"Joule heating","score":0.7303527593612671},{"id":"https://openalex.org/keywords/microelectrode","display_name":"Microelectrode","score":0.7142966985702515},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.6769887208938599},{"id":"https://openalex.org/keywords/retinal-implant","display_name":"Retinal implant","score":0.6506636738777161},{"id":"https://openalex.org/keywords/heat-transfer","display_name":"Heat transfer","score":0.582044243812561},{"id":"https://openalex.org/keywords/retinal","display_name":"Retinal","score":0.5343842506408691},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.512332558631897},{"id":"https://openalex.org/keywords/optoelectronics","display_name":"Optoelectronics","score":0.46302667260169983},{"id":"https://openalex.org/keywords/visual-prosthesis","display_name":"Visual prosthesis","score":0.4579881429672241},{"id":"https://openalex.org/keywords/multielectrode-array","display_name":"Multielectrode array","score":0.4546010196208954},{"id":"https://openalex.org/keywords/biocompatibility","display_name":"Biocompatibility","score":0.43256473541259766},{"id":"https://openalex.org/keywords/current-density","display_name":"Current density","score":0.4294763505458832},{"id":"https://openalex.org/keywords/joule-effect","display_name":"Joule effect","score":0.41906556487083435},{"id":"https://openalex.org/keywords/finite-element-method","display_name":"Finite element method","score":0.3184003233909607},{"id":"https://openalex.org/keywords/electrode","display_name":"Electrode","score":0.24237269163131714},{"id":"https://openalex.org/keywords/composite-material","display_name":"Composite material","score":0.19331881403923035},{"id":"https://openalex.org/keywords/mechanics","display_name":"Mechanics","score":0.16527894139289856},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.10558730363845825},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.09573480486869812},{"id":"https://openalex.org/keywords/chemistry","display_name":"Chemistry","score":0.09465733170509338},{"id":"https://openalex.org/keywords/structural-engineering","display_name":"Structural engineering","score":0.06923878192901611}],"concepts":[{"id":"https://openalex.org/C46435376","wikidata":"https://www.wikidata.org/wiki/Q1829750","display_name":"Multiphysics","level":3,"score":0.9507006406784058},{"id":"https://openalex.org/C2908752955","wikidata":"https://www.wikidata.org/wiki/Q540043","display_name":"Retinal Prosthesis","level":3,"score":0.7860626578330994},{"id":"https://openalex.org/C117926987","wikidata":"https://www.wikidata.org/wiki/Q210009","display_name":"Joule heating","level":2,"score":0.7303527593612671},{"id":"https://openalex.org/C111670793","wikidata":"https://www.wikidata.org/wiki/Q16979465","display_name":"Microelectrode","level":3,"score":0.7142966985702515},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.6769887208938599},{"id":"https://openalex.org/C158383150","wikidata":"https://www.wikidata.org/wiki/Q3149439","display_name":"Retinal implant","level":3,"score":0.6506636738777161},{"id":"https://openalex.org/C50517652","wikidata":"https://www.wikidata.org/wiki/Q179635","display_name":"Heat transfer","level":2,"score":0.582044243812561},{"id":"https://openalex.org/C2780827179","wikidata":"https://www.wikidata.org/wiki/Q422001","display_name":"Retinal","level":2,"score":0.5343842506408691},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.512332558631897},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.46302667260169983},{"id":"https://openalex.org/C2778560042","wikidata":"https://www.wikidata.org/wiki/Q540043","display_name":"Visual prosthesis","level":3,"score":0.4579881429672241},{"id":"https://openalex.org/C95967509","wikidata":"https://www.wikidata.org/wiki/Q1952355","display_name":"Multielectrode array","level":4,"score":0.4546010196208954},{"id":"https://openalex.org/C2777230088","wikidata":"https://www.wikidata.org/wiki/Q864426","display_name":"Biocompatibility","level":2,"score":0.43256473541259766},{"id":"https://openalex.org/C207740977","wikidata":"https://www.wikidata.org/wiki/Q234072","display_name":"Current density","level":2,"score":0.4294763505458832},{"id":"https://openalex.org/C106889404","wikidata":"https://www.wikidata.org/wiki/Q6294587","display_name":"Joule effect","level":3,"score":0.41906556487083435},{"id":"https://openalex.org/C135628077","wikidata":"https://www.wikidata.org/wiki/Q220184","display_name":"Finite element method","level":2,"score":0.3184003233909607},{"id":"https://openalex.org/C17525397","wikidata":"https://www.wikidata.org/wiki/Q176140","display_name":"Electrode","level":2,"score":0.24237269163131714},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.19331881403923035},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.16527894139289856},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.10558730363845825},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.09573480486869812},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.09465733170509338},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.06923878192901611},{"id":"https://openalex.org/C191897082","wikidata":"https://www.wikidata.org/wiki/Q11467","display_name":"Metallurgy","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/nems.2013.6559733","is_oa":false,"landing_page_url":"https://doi.org/10.1109/nems.2013.6559733","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"The 8th Annual IEEE International Conference on Nano/Micro Engineered and Molecular Systems","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.6299999952316284}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W1985980900","https://openalex.org/W2024741276","https://openalex.org/W2051923857","https://openalex.org/W2090597633","https://openalex.org/W2095891880","https://openalex.org/W2131773286","https://openalex.org/W2295233784","https://openalex.org/W2779397097","https://openalex.org/W4248262636","https://openalex.org/W6656586802"],"related_works":["https://openalex.org/W2017293056","https://openalex.org/W2345739822","https://openalex.org/W2778760765","https://openalex.org/W1637901622","https://openalex.org/W4388938748","https://openalex.org/W2027547973","https://openalex.org/W3180099257","https://openalex.org/W2909571771","https://openalex.org/W1025739944","https://openalex.org/W2130646311"],"abstract_inverted_index":{"The":[0,61],"Light":[1],"Switchable":[2],"Microelectrode":[3],"Array":[4],"(LSEMA)":[5],"is":[6,33,40,69],"a":[7],"novel":[8],"retinal":[9],"prosthetic":[10],"device,":[11],"which":[12,32],"has":[13],"been":[14],"proposed":[15],"by":[16],"our":[17],"group":[18],"previously.":[19],"In":[20],"this":[21],"paper,":[22],"the":[23,27,30,65],"temperature":[24,68],"rise":[25,66],"of":[26,34,53,67],"LSMEA":[28],"during":[29],"operation,":[31],"great":[35],"importance":[36],"to":[37,72],"its":[38],"biocompatibility,":[39],"simulated":[41],"with":[42],"COMSOL":[43],"Multiphysics.":[44],"We":[45],"obtain":[46],"both":[47],"stationary":[48],"and":[49,57],"transient":[50],"simulation":[51],"results":[52,62],"current":[54],"density":[55],"distribution":[56],"related":[58],"Joule":[59],"heating.":[60],"prove":[63],"that":[64],"small":[70],"enough":[71],"avoid":[73],"heat":[74],"degeneration":[75],"when":[76],"implanted":[77],"in":[78],"vivo.":[79]},"counts_by_year":[],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
